diff --git a/ChatLog_2020_06_18-07_18_43.csv b/ChatLog_2020_06_18-07_18_43.csv new file mode 100644 index 0000000..e841170 --- /dev/null +++ b/ChatLog_2020_06_18-07_18_43.csv @@ -0,0 +1,9 @@ +S 139 07:51:05 MRL : 90 +P0S139 07:51:18 MCC : 87 +S 140 07:51:19 MRL : 90-50 +S 141 07:51:29 MRL : 50-8 +S 142 07:51:33 MRL : 8 +P0S253 08:21:27 MCC : audio ist weg +P0S253 08:23:07 MCC : gut dann üben wir das jetzt mal ohne audio +P0S269 09:33:20 MCC : audio weg +S 283 09:49:45 MRL : 260 diff --git a/procedureLog_2020_06_18-07_18_43.csv b/procedureLog_2020_06_18-07_18_43.csv new file mode 100644 index 0000000..0735eda --- /dev/null +++ b/procedureLog_2020_06_18-07_18_43.csv @@ -0,0 +1,368 @@ +v4.32 Launch Procedure +current time;T-;step in procedure;step description;Annotation +; +07:18:45;T +02;1;BEGIN SEQUENCE: Power on EGSE; +07:18:49;T +06;2;Start wind weighting analysis; +07:18:52;T +09;3;Check CLD connection; +07:18:58;T +15;4;Switch ON CLD via Battery & check voltage (24 Volt); +07:19:06;T +23;5;Switch ON the primary and secondary supply switches on the Control Panel; +07:19:14;T +31;6;Switch ON Sup_24V_20A & check voltage (ca. 27,2 Volt); +07:19:45;T +01:02;14;Jump to Step Confirm storage capacity of cRio is greater than 300MB; +07:19:50;T +01:07;15;Start RT_VI; +07:19:53;T +01:10;16;Confirm storage capacity of cRio is greater than 300MB; +07:20:00;T +01:17;17;Open PID-VI and confirm it is running; +07:20:06;T +01:23;18;Rename PID-Logfile; +07:20:18;T +01:35;19;LAUNCH IN: 02:00:00; +07:20:40;T -01:59:38;19;BEGIN SEQUENCE: Connect Data Umbilical; +07:20:45;T -01:59:33;20;Confirm working personel is grounded; +07:21:04;T -01:59:14;21;Confirm ALL 8 bridges on the right side are inserted; +07:22:23;T -01:57:55;22;Confirm ALL 8 bridges on the left side are removed; +07:22:28;T -01:57:50;23;Connect Data Umbilical; +07:22:32;T -01:57:46;24;Remove EXT_24V GROUND Bridge (1R); +07:23:28;T -01:56:50;25;Remove MAIN_BUS GROUND Bridge (2R); +07:23:41;T -01:56:37;26;Remove OBC2_BAT GROUND Bridge (4R); +07:23:48;T -01:56:30;27;Remove PAYLOAD1 GROUND Bridge (5R); +07:23:54;T -01:56:24;28;Remove RECOVERY_BAT GROUND Bridge (7R); +07:23:57;T -01:56:21;29;Turn ON EPS_BAT; +07:24:08;T -01:56:10;30;Turn ON EPS_EXT_24V; +07:24:15;T -01:56:03;31;Insert EXT_24V Bridge (1L); +07:24:30;T -01:55:48;32;Confirm EXT_24V LED is ON; +07:24:34;T -01:55:44;33;Insert MAIN_BUS Bridge (2L); +07:24:39;T -01:55:39;34;Confirm MAIN_BUS LED is OFF (if ON pull MAIN_BUS Bridge (2L) & Insert all grounding Bridges on the right side; +07:24:45;T -01:55:33;35;Remove EPS RADIO SILENCE Bridge (3R); +07:24:53;T -01:55:25;36;Turn OFF EPS_BAT; +07:25:00;T -01:55:18;37;Confirm MAIN_BUS LED is ON; +07:25:05;T -01:55:13;38;Confirm 1 beep at Telemega; +07:25:12;T -01:55:06;39;Start OBC1;streichen +07:25:39;T -01:54:39;40;Confirm 3 beeps at OBC1; +07:30:39;T -01:49:39;41;Clear SD-Card-using FileZilla FTP; +07:33:02;T -01:47:16;42;Connect to sbRio using remote Access utility; +07:33:33;T -01:46:45;43;Open RT_Sub_HMI; +07:33:40;T -01:46:38;44;Confirm Main Chute button is disabled; +07:33:47;T -01:46:31;45;Check EPS hardware Voltages; +07:33:57;T -01:46:21;46;Check EGSE Currents; +07:34:07;T -01:46:11;47;Report on weather situation; +07:34:12;T -01:46:06;48;BEGIN SEQUENCE: Connect Fueling arm @HPSM; +07:34:18;T -01:46:00;49;Confirm working personel is grounded; +07:35:25;T -01:44:53;50;Confirm PPG 0 bar; +07:35:28;T -01:44:50;51;Remove Pneumatic Line from Fueling arm; +07:35:32;T -01:44:46;52;Move Fueling arm to rocket; +07:35:35;T -01:44:43;53;Couple Helium coupling; +07:35:43;T -01:44:35;54;Couple N2O coupling; +07:35:46;T -01:44:32;55;Reattach Pneumatic Line to Fueling arm @HPSM; +07:35:56;T -01:44:22;56;BEGIN SEQUENCE: EGSE sensor and actuator test; +07:36:01;T -01:44:17;57;Confirm that video recording is enabled @ MCC; +07:36:06;T -01:44:12;58;Confirm that Ignition Umbilical is disconnected; +07:36:11;T -01:44:07;59;Start PID data recording; +07:36:20;T -01:43:58;60;Close HPNV1; +07:36:59;T -01:43:19;61;Close HPNV2; +07:37:07;T -01:43:11;62;Switch OxDV to closed & check if magnetic valve LED is on; +07:37:36;T -01:42:42;63;Switch HPDV to closed & check if magnetic valve LED is on; +07:37:44;T -01:42:35;64;Check warning lamp on HPSM; +07:37:53;T -01:42:25;65;Remove loose equipment; +07:37:58;T -01:42:20;66;Turn ON & OFF Rocket Heater & confirm it's heating; +07:38:14;T -01:42:04;67;Turn ON & OFF N2O_Heater 1 & confirm it's heating; +07:38:18;T -01:42:00;68;Turn ON & OFF N2O_Heater 2 & confirm it's heating; +07:38:22;T -01:41:56;69;Turn ON & OFF He_Heater & confirm it's heating; +07:38:26;T -01:41:52;70;Verify Rocket Heater @ RDVT & RDVET; +07:39:07;T -01:41:11;71;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD; +07:39:48;T -01:40:30;72;Check Water Temperatures @ OxWT1, OxWT2, HPWT2; +07:40:02;T -01:40:16;73;Deactivate Rocket Heater; +07:40:09;T -01:40:09;74;Check OxV1 (CLD & RT_VI); +07:40:19;T -01:39:59;75;Check OxV2 (CLD & RT_VI); +07:40:26;T -01:39:52;76;Check MPV3 (CLD & RT_VI); +07:40:39;T -01:39:39;77;Check HPV1 (CLD & RT_VI); +07:40:46;T -01:39:32;78;Check HPV2 (CLD & RT_VI); +07:40:51;T -01:39:27;79;Check MPV1/2 (CLD & RT_VI); +07:40:56;T -01:39:22;80;Check RDV (CLD & RT_VI); +07:41:03;T -01:39:15;81;Check RMOxOV (CLD & RT_VI); +07:41:14;T -01:39:04;82;Check RMOxSV (CLD & RT_VI); +07:41:21;T -01:38:57;83;Activate Rocket Heater; +07:41:48;T -01:38:30;84;Verify Rocket Heater @ RDVT & RDVET; +07:42:02;T -01:38:16;85;Check RDV;heizi aus +07:42:18;T -01:38:01;86;Check RNCEV; +07:42:24;T -01:37:54;87;Check RMOxOV; +07:42:39;T -01:37:39;88;Check RMOxSV; +07:42:46;T -01:37:32;89;Disable RNCEV; +07:42:53;T -01:37:25;90;Confirm MBV closed; +07:43:04;T -01:37:14;91;Confirm that all valve switches are in OFF position (Except OxDV & HPDV); +07:43:13;T -01:37:05;92;Check loadcell by applying force to it; +07:43:33;T -01:36:45;93;Check RHPPT shows atmosphere; +07:43:39;T -01:36:39;94;Check ROxTPT shows atmosphere; +07:43:44;T -01:36:34;95;Check RIHPT shows atmosphere; +07:43:48;T -01:36:30;96;Check RCCPT shows atmosphere; +07:43:54;T -01:36:24;97;Check RBaro1 shows atmosphere; +07:44:01;T -01:36:17;98;Check RBaro2 shows atmosphere; +07:44:05;T -01:36:13;99;Check HPPT1 shows 0 bar; +07:44:11;T -01:36:07;100;Check HPPT2 shows 0 bar; +07:44:17;T -01:36:01;101;Check HPLPT shows 0 bar; +07:44:22;T -01:35:56;102;Check OxInPT1 shows 0 bar; +07:44:27;T -01:35:51;103;Check OxInPT2 shows 0 bar; +07:44:32;T -01:35:46;104;Check OxOutPT shows 0 bar; +07:44:36;T -01:35:42;105;Switch on N2O coupling & check if magnetic valve LED is on; +07:44:52;T -01:35:26;106;Switch on He coupling & check if magnetic valve LED is on; +07:45:02;T -01:35:16;107;Switch on swivle arm & check if magnetic valve LED is on;swivel weg +07:45:15;T -01:35:03;108;Switch off swivel arm & He coupling & N2O coupling; +07:45:22;T -01:34:56;109;BEGIN SEQUENCE: Ignition signal Test; +07:45:27;T -01:34:51;110;Confirm that Ignition Umbilical is disconnected; +07:45:31;T -01:34:47;111;Connect Ignition test receptical; +07:45:49;T -01:34:29;112;Plug in Bridges B1 and B2 into EGSE; +07:46:14;T -01:34:04;113;Confirm Soundsignal from Ignition Umbilical; +07:46:17;T -01:34:01;114;Turn on Ignition Secure Switch; +07:46:23;T -01:33:55;115;Turn on Ignition Switch for 2 Second & Confirm ignition signal received at sbRio & cRio; +07:46:48;T -01:33:30;116;Confirm that Ignition Switch is switched OFF and secured; +07:46:53;T -01:33:25;117;Turn off Ignition Secure Switch; +07:46:57;T -01:33:21;118;Remove Bridges B1 and B2; +07:47:13;T -01:33:05;119;Remove Ignition test receptical; +07:47:31;T -01:32:47;120;BEGIN SEQUENCE: Ground segment pressure test (PHASE YELLOW) ; +07:47:39;T -01:32:39;121;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;ohne MRL +07:48:13;T -01:32:05;122;Check Water Temperatures @ OxWT1, OxWT2, HPWT2; +07:48:24;T -01:31:54;123;Confirm He bottle 1 connector is attached; +07:48:32;T -01:31:46;124;Confirm He bottle 2 connector is attached; +07:48:37;T -01:31:41;125;Confirm N2O bottle 1 connector is attached; +07:48:44;T -01:31:34;126;Confirm N2O bottle 2 connector is attached; +07:48:48;T -01:31:30;127;Confirm hose between HPSM & N2OSM is connected on both ends; +07:48:55;T -01:31:23;128;Confirm hose between HPSM & Flight Segment is connected on both ends; +07:49:01;T -01:31:17;129;Confirm hose between N2OSM & Flight Segment is connected on both ends; +07:49:06;T -01:31:12;130;Confirm pneumatic hose is connected on both ends; +07:49:13;T -01:31:05;131;Put on safety equipment; +07:49:58;T -01:30:20;132;Confirm MBV is closed; +07:50:02;T -01:30:16;133;Confirm HPNV1 is closed; +07:50:07;T -01:30:11;134;Confirm HPNV2 is closed; +07:50:11;T -01:30:07;135;Take positions to open He Bottle 1; +07:50:16;T -01:30:02;136;Confirm HPV1 is closed; +07:50:22;T -01:29:56;137;Confirm MPV1/2 is closed; +07:50:28;T -01:29:50;138;Open He Bottle 1; +07:51:05;T -01:29:13;139;Check & compare pressure HPPT1 with HPPG1 (max 300 bar); +07:51:24;T -01:28:54;140;Check Gastech Silver HPPR1 (max 300 to 50 bar); +07:51:35;T -01:28:43;141;Check Harris PPR (50 to 8 bar); +07:51:41;T -01:28:37;142;Check pneumatic PPG (8 bar); +07:51:45;T -01:28:33;143;Step back; +07:51:50;T -01:28:28;144;Open & Close HPV1 SHORTLY & Check HPPT1;shrotly first +07:52:04;T -01:28:14;145;Check HPPT1 300 Bar; +07:52:12;T -01:28:06;146;Confirm HPLPT 0 Bar; +07:52:18;T -01:28:00;147;Open & Close HPV2 SHORTLY & Confirm HPPT2 0 bar; +07:52:30;T -01:27:48;148;Open & Close HPDV SHORTLY & Confirm HPLPT 0 bar; +07:52:42;T -01:27:36;149;Open & Close OxV1 SHORTLY; +07:52:49;T -01:27:29;150;Open & Close OxV2 SHORTLY; +07:52:56;T -01:27:22;151;Open & Close OxDV SHORTLY; +07:53:03;T -01:27:15;152;Open & Close MPV3 SHORTLY; +07:53:10;T -01:27:08;153;Open HPNV1 completely; +07:53:34;T -01:26:44;154;Step Back; +07:53:36;T -01:26:42;155;"Open & Close HPV1 STEPWISE untile HPLPT equal to HPPT1 and check for leakage @HPLPT (If leakage occurs proceed to passivation Procedure out of sequence)"; +07:53:57;T -01:26:21;156;"Confirm RHPPT & RoxTPT 1 Bar (If pressure is higher proceed to passivation Procedure out of sequence);obdh +07:54:17;T -01:26:01;157;Open HPV1; +07:54:26;T -01:25:52;158;"Open & Close HPV2 STEPWISE untile HPPT2 equal to HPLPT and check for leakage @HPPT2 (If leakage occurs proceed to passivation Procedure out of sequence)"; +07:54:47;T -01:25:31;159;Close HPV1; +07:54:54;T -01:25:24;160;Open STEPWISE HPDV & confirm HPLPT 0 Bar; +07:55:18;T -01:25:00;161;Open STEPWISE HPV2 & confirm HPPT2 0 Bar; +07:55:34;T -01:24:44;162;Close HPV2; +07:55:40;T -01:24:38;163;Close HPDV; +07:55:47;T -01:24:31;164;Open & Close STEPWISE MPV1/2 to 50 Bar @ OxInPT1 & OxInPT2; +07:56:09;T -01:24:09;165;Confirm MPV1/2 closed; +07:56:16;T -01:24:02;166;Open OxDV; +07:56:23;T -01:23:55;167;Open & Close STEPWISE MPV3 & Confirm 0 Bar @OxOutPT; +07:56:53;T -01:23:25;168;Confirm OxOutPT 0 Bar;vorher check raus +07:57:09;T -01:23:09;169;Check OxInPT1 and OxInPT2 for leakage (If leakage occurs proceed to passivation Procedure out of sequence); +07:57:19;T -01:22:59;170;Confirm MPV3 closed; +07:57:24;T -01:22:54;171;Open & Close STEPWISE OxV1 to 0 Bar @OxInPT1;gleich wie vorher +07:57:44;T -01:22:34;172;Open & Close STEPWISE OxV2 to 0 Bar @OxInPT2;doch nicht +07:57:58;T -01:22:20;173;Confirm OxOutPT 0 Bar; +07:58:04;T -01:22:14;174;Close OxDV; +07:58:10;T -01:22:08;175;Confirm HPLPT & OxOutPT 0 Bar; +07:58:17;T -01:22:01;176;Decouple N2O coupling; +07:58:32;T -01:21:46;177;Decouple Helium coupling; +07:58:43;T -01:21:35;178;Move arm away from rocket; +07:59:18;T -01:21:00;178;HOLD;abkürzungen +ausprobieren +08:02:37;T -01:21:00;178;CONTINUE; +08:02:40;T -01:20:56;179;Move arm to rocket; +08:02:42;T -01:20:54;180;Close He Bottle 1 and check HPSM for leakage (If leakage occurs proceed to passivation Procedure out of sequence); +08:02:58;T -01:20:38;181;Confirm no high pressures in Ground Segment; +08:03:28;T -01:20:08;182;Open MBV; +08:03:56;T -01:19:40;183;Check and compare pressure HPPT1 with HPPG1 0 Bar; +08:04:07;T -01:19:29;184;Close MBV; +08:04:17;T -01:19:19;185;Safety is ensured; +08:04:24;T -01:19:12;186;EGSE @MRL Go to MRL; +08:04:29;T -01:19:07;187;Switch OFF N20 coupling; +08:04:40;T -01:18:56;188;Switch OFF He coupling; +08:04:41;T -01:18:55;188;Switch OFF He coupling; +08:04:47;T -01:18:49;189;Confirm PPG 0 Bar; +08:05:43;T -01:17:53;190;Release Pneumatic lines of couplings @HPSM; +08:06:13;T -01:17:23;191;Confirm Fueling arm is switched OFF; +08:06:22;T -01:17:14;192;Confirm OxOutPT and HPLPT 0 bar; +08:06:36;T -01:17:00;193;Couple He coupling & Confirm it is connected properly; +08:06:51;T -01:16:45;194;Couple N2O coupling & Confirm it is connected properly; +08:06:58;T -01:16:38;195;Reattach Pneumatic Line to Fueling arm @HPSM; +08:07:11;T -01:16:25;196;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD; +08:07:30;T -01:16:06;197;Check Water Temperatures @ OxWT1, OxWT2, HPWT2; +08:07:40;T -01:15:56;198;HOLD; +08:07:47;T -01:15:49;199;CONTINUE AFTER HOLD; +08:07:52;T -01:15:44;200;BEGIN SEQUENCE: On Board System Test; +08:07:57;T -01:15:39;201;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD; +08:08:05;T -01:15:31;202;Check Water Temperatures @ OxWT1, OxWT2, HPWT2; +08:08:08;T -01:15:28;203;Check RDV; +08:08:24;T -01:15:12;204;Check RMOxOV; +08:08:33;T -01:15:03;205;Check RMOxSV; +08:08:44;T -01:14:52;206;Confirm RNCEV is disabled; +08:08:49;T -01:14:47;207;Confirm working personel is grounded; +08:09:08;T -01:14:28;208;Disconnect from sbRio; +08:09:25;T -01:14:11;209;Turn ON EPS_BAT (Rocket OFF); +08:09:34;T -01:14:02;210;Insert EPS RADIO SILENCE Bridge (3R); +08:10:13;T -01:13:23;211;Insert MAIN_BAT Bridge (3L); +08:10:18;T -01:13:18;212;Confirm MAIN_BAT LED is ON; +08:10:26;T -01:13:10;213;Insert OBC2_BAT Bridge (4L); +08:10:45;T -01:12:51;214;Confirm OBC2_BAT LED is ON; +08:10:48;T -01:12:48;215;Insert RECOVERY_BAT Bridge (7L); +08:11:00;T -01:12:36;216;Confirm RECOVERY_BAT LED is ON; +08:11:03;T -01:12:33;217;Insert PAYLOAD1 Bridge (5L); +08:11:26;T -01:12:10;218;Confirm PAYLOAD1 LED is OFF; +08:11:31;T -01:12:05;219;Insert PAYLOAD2 Bridge (6L); +08:11:42;T -01:11:54;220;Confirm PAYLOAD2 LED is ON; +08:11:46;T -01:11:50;221;Confirm MAIN_BUS LED is OFF; +08:11:51;T -01:11:45;222;Remove EPS RADIO SILENCE Bridge (3R); +08:11:57;T -01:11:39;223;Turn OFF EPS_BAT (Rocket ON); +08:12:09;T -01:11:27;224;Confirm MAIN_BUS LED is ON; +08:12:14;T -01:11:22;225;Confirm 1 beep at Telemega; +08:12:22;T -01:11:14;226;Confirm 3 beeps at OBC1;@egse +08:14:29;T -01:09:07;227;Remove BLACKBOX2 RADIO SILENCE Bridge (3R); +08:15:26;T -01:08:10;228;Connect to sbRio using remote Access utility;anmerkungstest +08:16:02;T -01:07:34;229;Open RT_Sub_HMI; +08:16:07;T -01:07:29;230;Confirm Main Chute button is disabled; +08:16:14;T -01:07:22;231;Check EPS hardware Voltages; +08:16:24;T -01:07:12;232;Check EGSE Currents; +08:16:30;T -01:07:06;233;Confirm CanSat is running;raus +08:16:40;T -01:06:56;234;Confirm BlackBox2 is running; +08:17:36;T -01:06:00;235;Turn OFF EPS_EXT_24V; +08:17:45;T -01:05:51;236;Confirm CanSat is running; +08:17:58;T -01:05:38;237;Confirm BlackBox2 is running; +08:18:08;T -01:05:28;238;Turn ON EPS_EXT_24V; +08:18:16;T -01:05:20;239;Disconnect from sbRio; +08:18:48;T -01:04:48;240;Turn ON EPS_BAT (Rocket OFF);camera payload check +08:19:09;T -01:04:27;241;BEGIN SEQUENCE: Prime Rocket; +08:19:15;T -01:04:21;242;Confirm EPS_BAT is ON (Rocket OFF); +08:19:21;T -01:04:15;243;Confirm working personel is grounded; +08:19:35;T -01:04:01;244;Confirm that RMDV is closed; +08:20:13;T -01:03:23;245;Close & secure HP maintenance cover; +08:20:17;T -01:03:19;246;Close & secure MainOX maintenance cover; +08:20:20;T -01:03:16;247;Turn on GoPro Camera at end of Launch Rail; +08:20:31;T -01:03:05;248;Confirm ALL 8 bridges on the right side are removed; +08:21:03;T -01:02:33;249;Confirm ALL 8 bridges on the left side are inserted; +08:21:07;T -01:02:29;250;Close & secure bridge maintenance cover; +08:21:11;T -01:02:25;251;Confirm spring retracted cover at He coupling is moving freely; +08:21:14;T -01:02:22;252;Confirm spring retracted cover at N2O coupling is moving freely; +08:21:17;T -01:02:19;253;Confirm that HP maintenance cover is closed & secured; +08:21:22;T -01:02:14;253;HOLD; +08:23:10;T -01:02:14;254;Confirm bridge maintenance cover is closed & secured; +08:25:01;T -01:02:14;254;CONTINUE; +08:25:06;T -01:02:09;255;Confirm that MainOX maintenance cover is closed & secured; +08:25:11;T -01:02:04;256;Leave MRL & return to MCC; +08:25:16;T -01:01:59;257;Connect Ignition Umbilical; +08:26:35;T -01:00:40;258;Elevate MRL to 90 degrees; +08:32:13;T -55:02;259;BEGIN SEQUENCE: Fueling Preparations (PHASE YELLOW); +08:32:28;T -54:47;260;Zero OxTank Mass; +08:32:44;T -54:31;261;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD; +08:32:55;T -54:20;262;Check Water Temperatures @ OxWT1, OxWT2, HPWT2; +08:33:05;T -54:10;263;Put on safety equipment; +08:33:26;T -53:49;263;HOLD;chb email and NI +09:29:54;T -53:49;263;CONTINUE; +09:30:14;T -53:29;264;Confirm HPNV1 is Open; +09:30:22;T -53:21;265;Confirm HPNV2 is Closed; +09:30:28;T -53:15;266;Open He Bottle 1; +09:31:34;T -52:09;267;Step back; +09:31:37;T -52:06;268;"Open & Close HPV1 STEPWISE untile HPLPT equal to HPPT1 and check for leakage @HPLPT (If leakage occurs continue with ""GSE Passivation Procedure"")"; +09:32:19;T -51:24;269;Open HPV1; +09:32:49;T -50:54;269;HOLD; +09:40:17;T -50:54;268;Jump to Step "Open & Close HPV2 STEPWISE untile HPPT2 equal to HPLPT and check for leakage @HPPT2 (If leakage occurs continue with ""GSE Passivation Procedure"")"; +09:40:57;T -50:54;269;Open HPV1; +09:40:58;T -50:54;269;CONTINUE; +09:41:07;T -50:45;270;"Open & Close HPV2 STEPWISE untile HPPT2 equal to HPLPT and check for leakage @HPPT2 (If leakage occurs continue with ""GSE Passivation Procedure"")"; +09:41:24;T -50:28;271;Close HPV1; +09:41:32;T -50:20;272;Open STEPWISE HPDV & Confirm HPLPT 0 Bar; +09:41:53;T -49:59;273;Confirm HPV1 is closed; +09:42:06;T -49:46;274;Confirm HPV2 is closed; +09:42:26;T -49:26;275;Close HPDV; +09:42:36;T -49:16;276;Open HPNV2 1/8 Rev; +09:43:05;T -48:47;277;Open & Close STEPWISE MPV1/2 to 50 Bar @ OxInPT1 & OxInPT2;step back before +09:44:25;T -47:27;278;Check & compare OxInPT1 with OxInPG1 based on Bottle temperature (max 50 bar); +09:45:20;T -46:32;279;Check & compare pressure OxInPT2 with OxInPG2 based on Bottle temperature (max 50 bar); +09:45:42;T -46:10;280;Check Temperature of N2O Bottle 1 @OxT1 & OxWT1 (max 22C); +09:46:03;T -45:49;281;Check Temperature of N2O Bottle 2 @OxT2 & OxWT2 (max 22C); +09:46:07;T -45:45;282;Open He Bottle 2; +09:49:38;T -42:14;283;Check & compare pressure HPPT2 with HPPG2 (max 315 bar); +09:50:03;T -41:49;284;CAUTION!; +09:51:29;T -40:23;285;Open N2O Bottle 1; +09:51:33;T -40:19;286;Check & compare pressure OxInPT 1 with OxInPG 1 (max 50 bar); +09:51:38;T -40:14;287;Open N2O Bottle 2; +09:51:40;T -40:12;288;Check & compare pressure OxInPT 2 with OxInPG 2 (max 50 bar); +09:51:49;T -40:03;289;Insert Ignition Bridges B1 and B2 into EGSE;erst ignition +09:54:28;T -37:24;289;HOLD; +09:55:13;T -37:24;290;Confirm Soundsignal from Ignition Umbilical; +09:55:16;T -37:24;290;CONTINUE; +09:55:19;T -37:21;291;Close ComTerm & Go to Block House; +09:55:25;T -37:15;292;Turn OFF MRL confirm lock; +09:55:29;T -37:11;293;Inform OPS to clear Launch Pad (Tel.: [!!!]); +09:55:35;T -37:05;294;Start wind weighting analysis; +09:55:39;T -37:01;295;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD; +09:56:28;T -36:12;296;Check Water Temperatures @ OxWT1, OxWT2, HPWT2; +09:56:36;T -36:04;297;HOLD; +09:56:42;T -35:58;298;Start Camera Karsten Lappöhn; +09:56:43;T -35:57;299;CONTINUE AFTER HOLD; +09:56:46;T -35:54;300;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD; +09:56:48;T -35:52;301;Check Water Temperatures @ OxWT1, OxWT2, HPWT2; +09:56:49;T -35:51;302;Confirm storage capacity of CRio is greater than 300MB; +09:56:57;T -35:43;303;BEGIN SEQUENCE Ox Fueling (PHASE RED); +09:57:03;T -35:37;304;Report on weather situation; +09:57:06;T -35:34;305;Announce end of Radio Silence; +09:57:09;T -35:31;306;Turn OFF EPS_BAT (Rocket ON); +09:57:24;T -35:16;307;Confirm 3 beeps at OBC1; +09:57:29;T -35:11;308;Connect to sbRio using remote Access utility; +09:57:33;T -35:07;309;Open RT_Sub_HMI; +09:57:35;T -35:05;310;Confirm RNCEV is disabled; +09:57:49;T -34:51;311;Confirm Main Chute button is disabled; +09:57:54;T -34:46;312;Check EPS hardware Voltages; +09:58:01;T -34:39;313;Check EGSE Currents; +09:58:08;T -34:32;314;Confirm RF451-Link; +09:58:51;T -33:49;315;Confirm GPS-lock; +09:58:55;T -33:45;316;Confirm Telemega-Link; +09:59:00;T -33:40;317;Turn on main TMTC screen; +09:59:05;T -33:35;318;Confirm CanSat is running; +09:59:08;T -33:32;319;Confirm BlackBox2 is running; +09:59:21;T -33:19;320;Request Permission to begin fueling from OPS; +10:00:01;T -32:39;320;HOLD; +10:00:31;T -32:39;320;CONTINUE; +10:00:33;T -32:37;321;Acknowledge start of Fueling; +10:00:58;T -32:12;322;Open & Close HPV1 STEPWISE to 50 Bar @ ROxTPT (stop every 10 bar & check ROxTBT & ROxTTT (approx. ambiente temp);feld zu klein +10:04:34;T -28:36;322;HOLD; +10:08:48;T -28:36;322;Jump to Step Open & Close HPV1 STEPWISE to more than 50 Bar @ RHPPT and confirm ROxTPT 50 Bar; +10:08:52;T -28:36;322;CONTINUE; +10:09:46;T -27:42;322;HOLD;hpcv prüfen +10:22:58;T -27:42;322;CONTINUE; +10:22:59;T -27:41;323;Confirm OxOutPT 0 Bar to check ROxCV tightness; +10:23:13;T -27:27;324;Open & Close HPV1 STEPWISE to more than 50 Bar @ RHPPT and confirm ROxTPT 50 Bar; +10:24:22;T -26:18;325;Confirm HPV1 is closed; +10:24:28;T -26:12;326;Open RDV SHORTLY, to check tightness @ RHPPT & ROxTPT (If leakages occur continue with Abort Procedure); +10:24:58;T -25:42;327;Open MPV1/2; +10:25:08;T -25:32;328;Open & Close MPV3 STEPWISE to 50 Bar @ OxOutPT; +10:25:13;T -25:27;329;Close MPV1/2; +10:25:17;T -25:23;330;Check & compare OxOutPT with OxInPT1; +10:25:24;T -25:16;331;Check if RHPPT & ROxTPT more than OxInPT1, If less Open & Close HPV1; +10:25:29;T -25:11;332;Zero OxTank Mass; +10:25:33;T -25:07;333;Write down Time; +10:25:39;T -25:01;334;Open OxV1; +10:25:43;T -24:57;335;Open & Close RDV STEPWISE until N2O bottle empty or 25kg OxTankMass, keep temperatures RDVT and RDVET above 10°C and Check delta ROxTPT and OxInPT1; +10:25:49;T -24:51;336;Verify Bottle Temperatures @ OxT1, OxT2, HPT2; +10:25:52;T -24:48;337;Verify Water Temperatures @ Ox@T1, OxWT2, HPWT2; +10:25:53;T -24:47;338;Close OxV1; +10:25:55;T -24:45;339;Check if Pressure rises in OxPT1, if Pressure rises relief via OxV1 or wait for Pressure relief valve; +10:25:58;T -24:42;340;Check & compare OxOutPT with OxInPT2; +10:26:01;T -24:39;341;Check & compare RHPPT & ROxTPT 50 Bar and more than OxInPT2, If less Open & Close HPV1; +10:26:03;T -24:37;342;Open OxV2 ; +10:26:05;T -24:35;343;Open & Close RDV STEPWISE to 25kg OxTankMass, keep temperatures RDVT and RDVET above 10°C and Check delta OxTPT and OxInPT1; +10:26:07;T -24:33;344;Close OxV2 ; +10:26:09;T -24:31;345;Check if Pressure rises in OxPT2, if Pressure rises relief via OxV2 or wait for Pressure relief valve; +10:26:12;T -24:28;346;Open OxDV STEPWISE until OxOutPT 0 Bar; +10:26:14;T -24:26;347;Check ROxCV for tightness @ ROxTPT; +10:26:17;T -24:23;348;Close OxDV; +10:26:19;T -24:21;349;Write down OxTankMass;32 kg +10:27:46;T -22:54;349;HOLD \ No newline at end of file