Logs/procedureLog_2020_06_16-13_...

472 lines
27 KiB
Plaintext

v4.31 Launch Procedure
current time;T-;step in procedure;step description;Annotation
;
13:49:39;T +27;1;BEGIN SEQUENCE: Power on EGSE;
13:49:43;T +32;2;Start wind weighting analysis;
13:50:18;T +01:07;3;Check CLD connection;
13:53:08;T +03:57;4;Switch ON CLD via Battery & check voltage (24 Volt);
13:53:32;T +04:21;5;Switch ON the primary and secondary supply switches on the Control Panel;
13:53:58;T +04:47;6;Switch ON Sup_24V_20A & check voltage (ca. 27,2 Volt);
13:54:25;T +05:14;7;Switch ON Sup_24V_10A & check voltage (ca. 27,2 Volt);
13:54:57;T +05:46;6;Jump to Step Switch ON Sup_12V_10A & check voltage (ca. 13,8 Volt);
13:55:15;T +06:04;7;Switch ON Sup_24V_10A & check voltage (ca. 27,2 Volt);
13:55:22;T +06:11;8;Switch ON Sup_12V_10A & check voltage (ca. 13,8 Volt);
13:55:29;T +06:18;9;Switch ON Bat_24V_20A & check voltage (ca. 27,9 Volt);
13:55:41;T +06:30;10;Switch ON Bat_24V_10A & check voltage (ca. 27,9 Volt);
13:55:47;T +06:36;11;Switch ON Bat_12V_10A & check voltage (ca. 13,8 Volt);
13:55:54;T +06:43;12;Switch ON Sup_24V_40A;
13:56:04;T +06:53;13;Switch ON Sup_5V_10A;
13:56:10;T +06:59;14;Connect to cRio;
13:56:47;T +07:36;15;Confirm storage capacity of cRio is greater than 300MB;schritt später
13:57:05;T +07:54;16;Start RT_VI;capacity
13:57:33;T +08:22;17;Open PID-VI and confirm it is running;
13:57:41;T +08:30;18;Rename PID-Logfile;
13:58:06;T +08:55;19;BEGIN SEQUENCE: Connect Data Umbilical;
13:58:12;T +09:01;20;Confirm working personel is grounded;
13:58:40;T +09:29;21;Confirm ALL 8 bridges on the right side are inserted;
13:58:53;T +09:42;22;Confirm ALL 8 bridges on the left side are removed;
13:59:01;T +09:50;23;Connect Data Umbilical;
14:00:30;T +11:19;24;Remove EXT_24V GROUND Bridge (1R);
14:01:20;T +12:09;25;Remove MAIN_BUS GROUND Bridge (2R);
14:01:30;T +12:18;26;Remove OBC2_BAT GROUND Bridge (4R);
14:01:49;T +12:38;27;Remove PAYLOAD1 GROUND Bridge (5R);
14:02:02;T +12:51;28;Remove RECOVERY_BAT GROUND Bridge (7R);
14:02:13;T +13:02;29;Turn ON EPS_BAT;
14:03:43;T +14:32;30;Turn ON EPS_EXT_24V;
14:04:41;T +15:30;31;Insert EXT_24V Bridge (1L);
14:05:11;T +16:00;32;Confirm EXT_24V LED is ON;
14:05:21;T +16:10;33;Insert MAIN_BUS Bridge (2L);
14:05:34;T +16:23;34;Confirm MAIN_BUS LED is OFF (if ON pull MAIN_BUS Bridge (2L) & Insert all grounding Bridges on the right side;
14:05:44;T +16:33;35;Remove EPS RADIO SILENCE Bridge (3R);
14:05:54;T +16:43;36;Turn OFF EGSE EPS_BAT;ohne EGSE
14:06:09;T +16:58;37;Confirm MAIN_BUS LED is ON;
14:06:24;T +17:13;38;Confirm 1 beep at Telemega;
14:06:39;T +17:28;39;Clear SD-Card-using FileZilla FTP;first obc starten
14:08:10;T +18:59;40;Connect to sbRio using remote Access utility;
14:08:58;T +19:47;41;Confirm 3 beeps at OBC1;früher
14:09:18;T +20:07;42;Open RT_Sub_HMI;
14:09:38;T +20:27;43;Confirm Main Chute button is disabled;
14:09:46;T +20:35;44;Check EPS hardware Voltages;
14:10:15;T +21:04;45;Check EGSE Currents;
14:11:24;T +22:13;46;Report on weather situation;
14:11:28;T +22:17;47;BEGIN SEQUENCE: Connect Fueling arm;
14:11:33;T +22:22;48;Confirm working personel is grounded;
14:11:45;T +22:34;49;Confirm PPG 0 bar;
14:12:08;T +22:57;50;Remove Pneumatic Line from Fueling arm;@HPSM
14:13:16;T +24:05;51;Move Fueling arm to rocket;
14:13:39;T +24:28;52;Couple Helium coupling;
14:14:25;T +25:14;53;Couple N2O coupling;
14:14:51;T +25:40;54;Reattach Pneumatic Line to Fueling arm;@HPSM
14:15:15;T +26:04;55;BEGIN SEQUENCE: EGSE sensor and actuator test;MCC
14:15:27;T +26:16;56;Confirm that video recording is enabled @ MCC;
14:15:34;T +26:23;57;Confirm that Ignition Umbilical is disconnected;
14:16:07;T +26:56;58;Start PID data recording;
14:16:15;T +27:04;59;Close HPNV1;
14:16:30;T +27:19;60;Close HPNV2;
14:16:36;T +27:25;61;Switch OxDV to closed & check if magnetic valve LED is on;
14:17:05;T +27:54;62;Switch HPDV to closed & check if magnetic valve LED is on;
14:17:17;T +28:06;63;Check warning lamp on HPSM;
14:17:36;T +28:25;64;Remove loose equipment;
14:18:06;T +28:55;65;Activate Heizi;and mrl confirm getting warm
rocket heater
14:18:46;T +29:35;66;Activate N2O_Heater 1;
14:19:20;T +30:09;67;Activate N2O_Heater 2;
14:19:28;T +30:17;68;Activate He_Heater;nochmal angucken nicht 3 gleichzeitig
14:19:56;T +30:45;69;Verify Heizi @ RDVT & RDVET;confirm temperature rises
14:21:17;T +32:06;70;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;
14:21:53;T +32:41;71;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;
14:22:06;T +32:55;72;Deactivate Heizi;
14:22:14;T +33:03;73;Check OxV1 (CLD & RT_VI);kill all heaters
14:22:54;T +33:43;74;Check OxV2 (CLD & RT_VI);
14:23:03;T +33:52;75;Check MPV3 (CLD & RT_VI);
14:23:12;T +34:01;76;Check HPV1 (CLD & RT_VI);
14:23:24;T +34:13;77;Check HPV2 (CLD & RT_VI);
14:23:32;T +34:21;78;Check MPV1/2 (CLD & RT_VI);
14:23:40;T +34:29;79;Check RDV (CLD & RT_VI);
14:23:58;T +34:47;80;Check RMOxOV (CLD & RT_VI);
14:24:07;T +34:56;81;Check RMOxSV (CLD & RT_VI);
14:24:16;T +35:05;82;Activate Heizi;
14:24:28;T +35:17;83;Verify Heizi @ RDVT & RDVET;..
14:24:47;T +35:36;84;Check RDV;
14:24:59;T +35:48;85;Check RNCEV;
14:25:06;T +35:55;86;Check RMOxOV;
14:25:16;T +36:05;87;Check RMOxSV;
14:25:28;T +36:17;88;Disable RNCEV;ohne MRL
14:25:50;T +36:39;89;Confirm MBV closed;
14:25:59;T +36:48;90;Confirm that all valve switches are in OFF position (Except OxDV & HPDV);
14:26:13;T +37:02;91;Check loadcell by applying force to it;rml egse anders rum
14:27:09;T +37:58;92;Check RHPPT shows atmosphere;
14:27:48;T +38:37;93;Check ROxTPT shows atmosphere;
14:27:55;T +38:44;94;Check RIHPT shows atmosphere;
14:28:01;T +38:50;95;Check RCCPT shows atmosphere;
14:28:07;T +38:56;96;Check RBaro1 shows atmosphere;
14:28:12;T +39:01;97;Check RBaro2 shows atmosphere;
14:28:18;T +39:07;98;Check HPPT1 shows 0 bar;
14:28:24;T +39:13;99;Check HPPT2 shows 0 bar;
14:28:30;T +39:19;100;Check HPLPT shows 0 bar;
14:28:36;T +39:25;101;Check OxInPT1 shows 0 bar;
14:28:43;T +39:32;102;Check OxInPT2 shows 0 bar;
14:28:49;T +39:38;103;Check OxOutPT shows 0 bar;
14:28:54;T +39:43;104;Switch on N2O coupling & check if magnetic valve LED is on;
14:29:13;T +40:02;105;Switch on He coupling & check if magnetic valve LED is on;
14:29:26;T +40:15;106;Switch on swivle arm & check if magnetic valve LED is on;
14:29:37;T +40:26;107;Switch off swivel arm & He coupling & N2O coupling;
14:29:47;T +40:36;108;BEGIN SEQUENCE: Ignition signal Test;
14:29:53;T +40:42;109;Confirm that Ignition Umbilical is disconnected;
14:29:59;T +40:48;110;Connect Ignition test receptical;
14:30:03;T +40:52;111;Plug in Bridges B1 and B2;into EGSE
14:30:39;T +41:28;111;HOLD;
14:32:29;T +41:28;111;CONTINUE;
14:32:31;T +41:29;112;Confirm Soundsignal from Ignition Umbilical;
14:32:35;T +41:34;113;Turn on Ignition Secure Switch;
14:33:09;T +42:08;114;Turn on Ignition Switch for 2 Second & Confirm ignition signal received at sbRio & cRio;Wiederstände und stromsensor checken
14:37:13;T +46:11;114;HOLD;
14:37:49;T +46:11;114;CONTINUE;
14:37:55;T +46:17;115;Confirm that Ignition Switch is switched OFF and secured;
14:38:02;T +46:24;116;Turn off Ignition Secure Switch;
14:38:08;T +46:30;117;Remove Bridges B1 and B2;
14:38:21;T +46:43;118;Remove Ignition test receptical;2x raus
14:38:45;T +47:07;119;Remove Ignition test receptical;
14:38:49;T +47:11;120;BEGIN SEQUENCE: Ground segment pressure test (PHASE YELLOW) ;
14:39:02;T +47:24;121;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;Phase yellow wann?
14:40:32;T +48:54;122;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;
14:40:41;T +49:03;123;Confirm He bottle 1 connector is attached;
14:41:03;T +49:25;124;Confirm He bottle 2 connector is attached;
14:41:10;T +49:32;125;Confirm N2O bottle 1 connector is attached;
14:41:16;T +49:38;126;Confirm N2O bottle 2 connector is attached;
14:41:17;T +49:39;126;Confirm N2O bottle 2 connector is attached;
14:41:21;T +49:43;127;Confirm hose between HPSM & N2OSM is connected on both ends;
14:41:44;T +50:06;128;Confirm hose between HPSM & Flight Segment is connected on both ends;
14:41:49;T +50:11;129;Confirm hose between N2OSM & Flight Segment is connected on both ends;
14:41:58;T +50:20;130;Confirm pneumatic hose is connected on both ends;
14:42:16;T +50:38;131;Put on safety equipment;
14:42:41;T +51:03;132;Confirm MBV is closed;
14:43:20;T +51:42;133;Confirm HPNV1 is closed;
14:43:28;T +51:50;134;Confirm HPNV2 is closed;
14:43:33;T +51:55;135;Take positions to open He Bottle 1;
14:43:45;T +52:07;136;Confirm HPV1 is closed;
14:43:56;T +52:18;137;Confirm MPV1/2 is closed;
14:44:03;T +52:25;138;Open He Bottle 1;
14:47:18;T +55:40;139;Check & compare pressure HPPT1 with HPPG1 (max 300 bar);egse
14:47:39;T +56:01;140;Check Gastech Silver HPPR1 (max 300 to 50 bar);
14:47:50;T +56:12;141;Check Harris PPR (50 to 8 bar);
14:47:56;T +56:18;142;Check pneumatic PPG (8 bar);
14:48:04;T +56:26;143;Step back;
14:48:18;T +56:40;144;Open & Close HPV1 SHORTLY & Check HPPT1;
14:48:36;T +56:58;145;Check HPPT1 300 Bar;
14:48:48;T +57:10;146;Confirm HPLPT 0 Bar;
14:48:55;T +57:17;147;Open & Close HPV2 SHORTLY & Confirm HPPT2 0 bar;
14:49:23;T +57:45;148;Open & Close HPDV SHORTLY & Confirm HPLPT 0 bar;
14:49:43;T +58:05;149;Open & Close OxV1 SHORTLY;
14:49:57;T +58:19;150;Open & Close OxV2 SHORTLY;
14:50:09;T +58:31;151;Open & Close OxDV SHORTLY;
14:50:20;T +58:42;152;Open & Close MPV3 SHORTLY;
14:50:31;T +58:53;153;Open HPNV1 completely;
14:51:35;T +59:56;154;Step Back;
14:51:59;T +01:00:21;155;"Open & Close HPV1 STEPWISE untile HPLPT equal to HPPT1 and check for leakage @HPLPT (If leakage occurs proceed to passivation Procedure out of sequence)";
14:52:30;T +01:00:52;156;"Confirm RHPPT & RoxTPT 1 Bar (If pressure is higher proceed to passivation Procedure out of sequence);OBDH
14:52:50;T +01:01:12;157;Open HPV1;
14:53:06;T +01:01:28;158;"Open & Close HPV2 STEPWISE untile HPPT2 equal to HPLPT and check for leakage @HPPT2 (If leakage occurs proceed to passivation Procedure out of sequence)";
14:54:04;T +01:02:26;159;Close HPV1;
14:54:16;T +01:02:38;160;Open HPDV & confirm HPLPT 0 Bar;STepwise
14:54:55;T +01:03:17;161;Open HPV2 & confirm HPPT2 0 Bar;
14:55:18;T +01:03:40;162;Close HPV2;
14:55:25;T +01:03:47;163;Close HPDV;
14:55:41;T +01:04:03;164;Open & Close STEPWISE MPV1/2 to 50 Bar @ OxInPT1 & OxInPT2;STepwise first everyone
14:56:13;T +01:04:35;165;Confirm MPV1/2 closed;
14:56:23;T +01:04:45;166;Open OxDV;
14:56:44;T +01:05:06;167;Open & Close STEPWISE MPV3 to 0 Bar @OxOutPT;vorher schon 0 bar
14:57:47;T +01:06:09;168;Check OxInPT1 and OxInPT2 for leakage (If leakage occurs proceed to passivation Procedure out of sequence);
14:57:58;T +01:06:20;169;Confirm MPV3 closed;
14:58:05;T +01:06:27;170;Open & Close STEPWISE OxV1 to 0 Bar @OxInPT1;
14:58:24;T +01:06:46;171;Open & Close STEPWISE OxV2 to 0 Bar @OxInPT2;
14:58:40;T +01:07:02;172;Confirm OxOutPT 0 Bar;
14:58:47;T +01:07:09;173;Close OxDV;
14:58:56;T +01:07:18;174;Confirm HPLPT & OxOutPT 0 Bar;
14:59:14;T +01:07:35;175;Decouple N2O coupling;
14:59:33;T +01:07:55;176;Decouple Helium coupling;
14:59:49;T +01:08:11;177;Move arm away from rocket;
15:00:56;T +01:09:18;177;HOLD;
15:03:36;T +01:09:18;177;CONTINUE;
15:06:10;T +01:11:52;177;HOLD;
15:09:20;T +01:11:52;177;CONTINUE;
15:09:31;T +01:12:03;178;Move arm to rocket;
15:09:45;T +01:12:17;179;Close He Bottle 1 and check HPSM for leakage (If leakage occurs proceed to passivation Procedure out of sequence);
15:10:16;T +01:12:48;180;Open MBV;egse pressure test
15:10:56;T +01:13:28;181;Check and compare pressure HPPT1 with HPPG1 0 Bar;confirm is 0 bar
15:11:18;T +01:13:50;182;Close MBV;
15:11:26;T +01:13:58;183;Safety is ensured;
15:11:33;T +01:14:05;184;EGSE @MRL to MRL;anders nennen
15:12:00;T +01:14:32;185;Switch OFF N20 coupling;
15:12:11;T +01:14:42;186;Switch OFF He coupling;
15:12:17;T +01:14:49;187;Confirm working personel is grounded;
15:12:48;T +01:15:20;188;Confirm PPG 0 Bar;grounded ist verkehrt
15:13:12;T +01:15:44;189;Release Pneumatic lines of couplings;
15:14:00;T +01:16:32;190;Confirm Fueling arm is switched OFF;
15:14:28;T +01:17:00;191;Confirm OxOutPT and HPLPT 0 bar;
15:14:38;T +01:17:10;192;Couple He coupling;
15:14:44;T +01:17:16;193;Couple N2O coupling;
15:14:47;T +01:17:19;194;Confirm He coupling is connected properly;2 schritte vorher
15:14:58;T +01:17:30;195;Confirm N2O coupling is connected properly;
15:15:02;T +01:17:34;196;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;
15:15:11;T +01:17:43;197;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;
15:15:16;T +01:17:48;198;HOLD;
15:15:19;T +01:17:51;198;HOLD;
15:15:56;T +01:17:51;198;CONTINUE;mcc
15:16:09;T +01:18:04;199;CONTINUE AFTER HOLD;
15:16:11;T +01:18:06;200;BEGIN SEQUENCE: On Board System Test;mcc
15:16:20;T +01:18:15;201;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;
15:16:30;T +01:18:25;202;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;
15:16:32;T +01:18:27;203;Check RDV;
15:16:44;T +01:18:39;204;Check RNCEV;raus @CD
15:18:08;T +01:20:03;205;Check RMOxOV;
15:18:28;T +01:20:23;206;Check RMOxSV;
15:18:34;T +01:20:29;207;Disable RNCEV;confirm that disabled
15:18:53;T +01:20:48;208;Confirm working personel is grounded;
15:19:10;T +01:21:05;209;Disconnect from sbRio;
15:19:25;T +01:21:20;210;Turn ON EPS_BAT (Rocket OFF);
15:19:37;T +01:21:32;211;Insert EPS RADIO SILENCE Bridge (3R);
15:20:21;T +01:22:16;212;Insert MAIN_BAT Bridge (3L);
15:20:43;T +01:22:38;213;Confirm MAIN_BAT LED is ON;
15:20:46;T +01:22:41;214;Insert OBC2_BAT Bridge (4L);
15:21:01;T +01:22:56;215;Confirm OBC2_BAT LED is ON;
15:21:05;T +01:23:00;216;Insert RECOVERY_BAT Bridge (7L);
15:21:18;T +01:23:13;217;Confirm RECOVERY_BAT LED is ON;
15:21:20;T +01:23:15;218;Insert PAYLOAD1 Bridge (5L);
15:22:15;T +01:24:10;219;Confirm PAYLOAD1 LED is OFF;
15:22:25;T +01:24:20;220;Insert PAYLOAD2 Bridge (6L);
15:22:40;T +01:24:34;221;Confirm PAYLOAD2 LED is ON;
15:22:42;T +01:24:37;222;Confirm MAIN_BUS LED is OFF;
15:22:47;T +01:24:42;223;Remove EPS RADIO SILENCE Bridge (3R);
15:22:56;T +01:24:51;224;Turn OFF EPS_BAT (Rocket ON);
15:23:09;T +01:25:04;225;Confirm MAIN_BUS LED is ON;
15:23:14;T +01:25:09;226;Confirm 1 beep at Telemega;
15:24:16;T +01:26:11;227;Remove BLACKBOX2 RADIO SILENCE Bridge (3R);
15:24:27;T +01:26:22;228;Connect to sbRio using remote Access utility;
15:25:12;T +01:27:07;229;Confirm 3 beeps at OBC1;vorher
15:25:31;T +01:27:26;230;Open RT_Sub_HMI;
15:25:38;T +01:27:33;231;Confirm Main Chute button is disabled;
15:25:44;T +01:27:39;232;Check EPS hardware Voltages;
15:25:52;T +01:27:47;233;Check EGSE Currents;
15:26:08;T +01:28:03;234;Confirm CanSat is running;nicht phase rot
15:26:29;T +01:28:24;235;Confirm BlackBox2 is running;
15:26:52;T +01:28:47;235;HOLD;
15:28:36;T +01:28:47;235;CONTINUE;
15:29:17;T +01:29:28;236;Turn OFF EPS_EXT_24V;
15:29:40;T +01:29:51;237;Confirm CanSat is running;
15:29:45;T +01:29:56;238;Confirm BlackBox2 is running;
15:29:53;T +01:30:03;239;Turn ON EPS_EXT_24V;
15:30:01;T +01:30:12;240;Disconnect from sbRio;
15:30:19;T +01:30:30;241;Turn ON EPS_BAT (Rocket OFF);
15:30:30;T +01:30:41;242;BEGIN SEQUENCE: Prime Rocket;mcc
15:30:39;T +01:30:50;243;Confirm EPS_BAT is ON (Rocket OFF);
15:30:49;T +01:31:00;244;Confirm working personel is grounded;
15:30:54;T +01:31:05;245;Confirm that RMDV is closed;
15:33:01;T +01:33:12;246;Close & secure HP maintenance cover;
15:33:21;T +01:33:32;247;Close & secure MainOX maintenance cover;
15:33:26;T +01:33:37;248;Turn on GoPro Camera at end of Launch Rail;
15:33:32;T +01:33:43;249;Confirm ALL 8 bridges on the right side are removed;
15:33:56;T +01:34:07;250;Confirm ALL 8 bridges on the left side are inserted;
15:34:03;T +01:34:14;251;Close & secure bridge maintenance cover;
15:34:09;T +01:34:20;252;Confirm spring retracted cover at He coupling is moving freely;
15:34:18;T +01:34:29;253;Confirm spring retracted cover at N2O coupling is moving freely;
15:34:22;T +01:34:33;254;Confirm that HP maintenance cover is closed & secured;
15:34:26;T +01:34:37;255;Confirm bridge maintenance cover is closed & secured;
15:34:31;T +01:34:42;256;Confirm that MainOX maintenance cover is closed & secured;
15:34:34;T +01:34:45;257;Leave MRL & return to MCC;
15:34:43;T +01:34:54;258;Connect Ignition Umbilical;
15:35:36;T +01:35:47;259;Elevate MRL to 90 degrees;
15:37:59;T +01:38:10;260;Zero OxTank Mass;
15:38:23;T +01:38:34;261;BEGIN SEQUENCE: Fueling Preparations (PHASE YELLOW);mit vorher tauschen
15:38:40;T +01:38:51;262;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;
15:38:45;T +01:38:56;263;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;
15:38:48;T +01:38:59;264;Put on safety equipment;
15:39:54;T +01:40:05;265;Confirm HPNV1 is Open;
15:40:06;T +01:40:17;266;Confirm HPNV2 is Closed;
15:40:12;T +01:40:23;267;Open He Bottle 1;
15:41:31;T +01:41:42;268;Step back;
15:41:45;T +01:41:56;269;"Open & Close HPV1 STEPWISE untile HPLPT equal to HPPT1 and check for leakage @HPLPT (If leakage occurs continue with ""GSE Passivation Procedure"")";
15:42:16;T +01:42:27;270;Open HPV1;
15:42:28;T +01:42:39;271;"Open & Close HPV2 STEPWISE untile HPPT2 equal to HPLPT and check for leakage @HPPT2 (If leakage occurs continue with ""GSE Passivation Procedure"")";
15:42:50;T +01:43:01;272;Close HPV1;
15:42:58;T +01:43:09;273;Open HPDV & Confirm HPLPT 0 Bar;stepwise
15:43:38;T +01:43:49;274;Confirm HPV1 is closed;
15:43:51;T +01:44:02;275;Confirm HPV2 is closed;
15:44:01;T +01:44:12;276;Open HPNV2 1/8 Rev;
15:44:51;T +01:45:02;277;Close HPDV;angucken warum dahinter
15:45:17;T +01:45:28;278;Open & Close STEPWISE MPV1/2 to 50 Bar @ OxInPT1 & OxInPT2;
15:45:46;T +01:45:57;279;Check & compare OxInPT1 with OxInPG1 based on Bottle temperature (max 50 bar);
15:46:08;T +01:46:19;280;Check & compare pressure OxInPT2 with OxInPG2 based on Bottle temperature (max 50 bar);
15:46:26;T +01:46:37;281;Check Temperature of N2O Bottle 1 @OxT1 & OxWT1 (max 22C);
15:46:32;T +01:46:43;282;Check Temperature of N2O Bottle 2 @OxT2 & OxWT2 (max 22C);
15:46:39;T +01:46:49;283;Open He Bottle 2;
15:47:24;T +01:47:35;284;Check & compare pressure HPPT2 with HPPG2 (max 315 bar);
15:47:52;T +01:48:03;285;CAUTION!;
15:48:08;T +01:48:19;286;Open N2O Bottle 1;
15:48:13;T +01:48:24;287;Check & compare pressure OxInPT 1 with OxInPG 1 (max 50 bar);
15:48:20;T +01:48:31;288;Open N2O Bottle 2;
15:48:27;T +01:48:38;289;Check & compare pressure OxInPT 2 with OxInPG 2 (max 50 bar);
15:48:38;T +01:48:49;290;Insert Ignition Bridges B1 and B2 into EGSE;
15:49:15;T +01:49:26;291;Confirm Soundsignal from Ignition Umbilical;
15:49:18;T +01:49:29;292;Close ComTerm & Go to Block House;
15:49:25;T +01:49:36;293;Turn OFF MRL confirm lock;
15:49:34;T +01:49:45;294;Inform OPS to clear Launch Pad (Tel.: [!!!]);
15:49:39;T +01:49:50;295;Start wind weighting analysis;
15:51:15;T +01:51:26;296;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;ohne mrl
15:51:30;T +01:51:41;297;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;
15:51:42;T +01:51:53;298;HOLD;
15:51:46;T +01:51:56;298;HOLD;
15:51:48;T +01:51:57;298;CONTINUE;
15:51:50;T +01:51:59;298;HOLD;
15:51:51;T +01:51:59;299;Start Camera Karsten Lappöhn;
15:51:57;T +01:51:59;300;CONTINUE AFTER HOLD;
15:52:00;T +01:51:59;300;CONTINUE;
15:52:01;T +01:52:00;301;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;ohne mrl
15:52:31;T +01:52:29;302;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;
15:52:46;T +01:52:45;303;Confirm storage capacity of CRio is greater than 300MB;
15:52:57;T +01:52:56;304;Confirm RNCEV is disabled;verkehrt
15:53:37;T +01:53:36;305;BEGIN SEQUENCE Ox Fueling (PHASE RED);
15:54:07;T +01:54:06;306;Report on weather situation;
15:54:14;T +01:54:13;307;Announce end of Radio Silence;
15:54:25;T +01:54:24;308;Turn OFF EPS_BAT (Rocket ON);
15:54:36;T +01:54:35;309;Connect to sbRio using remote Access utility;3 beeps vorher
15:55:33;T +01:55:32;310;Confirm 3 beeps at OBC1;
15:55:36;T +01:55:35;311;Open RT_Sub_HMI;
15:56:08;T +01:56:07;312;Confirm Main Chute button is disabled;
15:56:16;T +01:56:15;313;Check EPS hardware Voltages;rncev auch disablen
15:56:57;T +01:56:56;314;Check EGSE Currents;phase numbers
15:57:21;T +01:57:20;315;Confirm RF451-Link;
15:57:30;T +01:57:29;316;Confirm GPS-lock;
15:58:09;T +01:58:08;317;Confirm Telemega-Link;
15:58:19;T +01:58:17;318;Test Connection to STX3;
15:58:29;T +01:58:28;319;Confirm that STX3 Packages are received by email;
15:58:38;T +01:58:37;320;Turn on main TMTC screen;
15:59:14;T +01:59:13;321;Confirm CanSat is running;
15:59:55;T +01:59:54;322;Confirm BlackBox2 is running;
16:00:23;T +02:00:22;323;Request Permission to begin fueling from OPS;
16:00:40;T +02:00:39;324;Acknowledge start of Fueling;
16:01:40;T +02:01:39;352;Jump to Step Provide OxTankMass and temperature readings to Wind weighting station;
16:01:57;T +02:01:56;353;Verify He Bottle 2 Temperature @HPT2 & @HPWT2 (turn ON He_Heater if necessary) ;
16:02:29;T +02:02:28;354;Provide OxTankMass and temperature readings to Wind weighting station;
16:02:39;T +02:02:38;355;Confirm OxV1 & OxV2 closed;letyter schritt telefonnummer
16:02:54;T +02:02:53;356;Confirm OxOutPT 0 Bar;
16:03:00;T +02:02:59;357;Decouple N2O coupling;
16:03:13;T +02:03:12;358;Confirm End of Oxidator Fueling to OPS;
16:03:22;T +02:03:21;359;Start wind weighting analysis;
16:03:29;T +02:03:28;360;Check RF451-Link;
16:03:35;T +02:03:34;361;Check GPS-lock;
16:03:37;T +02:03:36;362;Check Telemega-Link;
16:03:40;T +02:03:39;363;Verify He Bottle 2 Temperature @HPT2 & @HPWT2 (turn ON/OFF He_Heater if necessary) ;
16:03:52;T +02:03:51;364;HOLD (Last possible scheduled HOLD);
16:03:56;T +02:03:55;364;HOLD;
16:04:01;T +02:03:55;365;Align MRL to Launch Trajectory;
16:04:08;T +02:03:55;366;Turn audio volume down;
16:04:12;T +02:03:55;367;Turn OFF ComTerm step delay;
16:04:22;T +02:03:55;368;Talk through Ignition Sequence;
16:07:40;T +02:03:55;369;Wait for OPS to confirm final MRL adjustment;
16:07:44;T +02:03:55;370;Report on weather situation;
16:07:48;T +02:03:55;371;CONTINUE AFTER HOLD;
16:07:50;T +02:03:55;371;CONTINUE;
16:07:51;T +02:03:56;372;Start Video recording in Block House;
16:07:56;T +02:04:01;373;Verify He Bottle 2 Temperature @HPT2 & @HPWT2 (turn ON/OFF He_Heater if necessary) ;
16:08:05;T +02:04:10;374;BEGIN SEQUENCE: Switching to Internal Power Sequence;doppelt sequence
16:08:21;T +02:04:26;375;Turn OFF EPS_EXT_24V (Switch to internal Power);
16:08:53;T +02:04:58;376;Confirm EPS Voltages are within limits;
16:09:04;T +02:05:09;377;Confirm RF451 Transmitting;
16:09:07;T +02:05:12;378;Confirm RF451-Link;
16:09:08;T +02:05:13;379;Confirm GPS-lock;
16:09:10;T +02:05:15;380;Confirm Telemega-Link;
16:09:11;T +02:05:16;381;Switch to PREARMED;
16:09:17;T +02:05:22;382;Confirm Payload is running;
16:09:22;T +02:05:27;383;Confirm BlackBox2 is ready for launch;
16:11:38;T +02:07:43;384;Confirm that videorecording @ MCC is running;
16:11:43;T +02:07:48;385;BEGIN SEQUENCE: High Pressure Fueling;
16:11:51;T +02:07:56;386;Verify He Bottle 2 Temperature @HPT2 & @HPWT2 (turn ON/OFF He_Heater if necessary) ;
16:12:10;T +02:08:15;387;Open & Close HPV1 STEPWISE until RHPPT 300 Bar or pressure equal to He Bottle 1;
16:12:22;T +02:08:27;388;Open & Close HPV2 STEPWISE until RHPPT 300 Bar ;
16:12:29;T +02:08:34;389;Open & close HPDV STEPWISE until HPLPT 0 Bar ;
16:12:33;T +02:08:38;390;Confirm HPDV closed;
16:12:37;T +02:08:42;391;Check for leakage & HPLPT 0 Bar & RHPPT 300 Bar ;
16:12:42;T +02:08:47;392;Turn OFF He_Heater;
16:12:47;T +02:08:52;393;Acknowledge end of Fueling;
16:12:54;T +02:08:59;394;Confirm End of Fueling to OPS;HP
16:13:08;T +02:09:13;395;BEGIN SEQUENCE: Disconnecting Fueling Arm;
16:13:14;T +02:09:19;396;Confirm HPV1 & HPV2 closed;
16:13:23;T +02:09:28;397;Confirm HPLPT 0 Bar ;
16:13:30;T +02:09:35;398;Decouple Helium coupling;
16:13:45;T +02:09:50;399;LAUNCH IN: 00:00:04;
16:13:52;T +03;399;LAUNCH IN: 00:04:04;
16:13:54;T -04:02;399;Confirm Helium coupling is disconnected;
16:14:01;T -03:55;400;Move fueling arm away from rocket;
16:14:17;T -03:39;401;Confirm Fueling Arm away to OPS;
16:14:28;T -03:28;402;Prepare for Launch;
16:14:48;T -03:08;403;Confirm ready for launch;
16:15:02;T -02:54;404;Confirm ready for launch;
16:15:25;T -02:31;405;Set Go/No-Go System to Go;
16:15:47;T -02:09;406;Wait for Authorization for Launch;
16:17:11;T -45;407;BEGIN SEQUENCE: Ignition;
16:17:14;T -42;408;T-50 ARM;
16:17:21;T -35;409;T-40 Confirm all status indicators green;
16:17:30;T -26;410;T-30 Disconnect from sbRio;
16:18:20;T +24;411;T-10 Turn on Ignition Secure;
16:18:21;T +25;412;T-3: Ignition;
16:18:22;T +26;413;T+0: Verify RMOxOV Open (Launched);
16:18:23;T +27;414;T+1: Turn OFF Ignition;
16:18:24;T +28;415;T+5: Turn OFF Ignition Secure;
16:18:25;T +29;416;T+20: Verify RMOxOV Closed and RMOxSV Open (Cruise);
16:18:29;T +33;417;T+50: Verify RNCEV Open (Drogue);
16:18:30;T +34;418;T+310: Verify Main Chute Deployed and RDV Open (Main);
16:18:31;T +35;419;T+600: Verify (Landed);
16:18:46;T +50;420;BEGIN SEQUENCE: PASSIVATION (PHASE YELLOW);
16:18:52;T +56;421;Announce BEGIN of Radio Silence;
16:19:00;T +01:04;422;Turn audio volume up;
16:19:03;T +01:07;423;Go to MRL, THEN...;
16:19:06;T +01:10;424;Close N2O Bottle 1 & N2O Bottle 2, THEN...;
16:19:13;T +01:16;425;RETURN to Block House;
16:19:14;T +01:18;426;Open OxDV;
16:19:40;T +01:43;426;HOLD;
16:21:07;T +01:43;426;CONTINUE;
16:21:17;T +01:53;427;Open OxV1;
16:21:41;T +02:17;428;Confirm OxInPT1 & OxOutPT 0 Bar;
16:21:57;T +02:33;429;Close OxV1;
16:22:06;T +02:42;430;Open OxV2;
16:22:30;T +03:06;431;Confirm OxInPT2 & OxOutPT 0 Bar;
16:22:38;T +03:14;432;Close OxV2;
16:22:44;T +03:20;433;Close OxDV;
16:22:52;T +03:28;434;Go to MRL, confirm OxInPG1 & OxInPG2 0 Bar, else RETURN to Block House, THEN...;
16:23:02;T +03:37;435;Close He Bottle 2, THEN...;
16:23:04;T +03:40;436;Write down remaining Pressure of He Bottle 2, THEN...;
16:23:08;T +03:44;437;Return to Block House;
16:23:12;T +03:48;438;Open HPDV;
16:23:28;T +04:04;439;Open HPV2;
16:23:43;T +04:19;440;Confirm pressure HPLPT & HPPT2 0 Bar;
16:23:58;T +04:34;441;Close HPV2;
16:24:09;T +04:45;442;Close HPDV;
16:24:18;T +04:54;443;Go to Testrig, confirm HPPG2 0 Bar, else return to Block House, THEN...;
16:24:29;T +05:05;444;Close He Bottle 1, THEN ...;
16:24:31;T +05:07;445;Open ComTerm;
16:25:11;T +05:47;446;Turn ON ComTerm step delay;confirm lock
16:25:27;T +06:03;447;Write down remaining Pressure of He Bottle 1;
16:25:36;T +06:12;448;Step back;mrl /egse remaining pressure
16:25:53;T +06:29;449;Open HPDV;
16:26:09;T +06:45;450;Open HPV1;
16:26:27;T +07:03;451;Confirm pressure HPLPT & HPPT1 0 Bar;
16:26:36;T +07:12;452;Close HPV1;
16:26:44;T +07:20;453;Close HPDV;
16:26:51;T +07:27;454;Pressure Check;
16:27:13;T +07:49;455;Open MBV;
16:27:25;T +08:01;456;Check and compare pressure HPPT1 with HPPG1;
16:27:40;T +08:16;457;Close MBV;
16:27:46;T +08:22;458;Take out B1 & B2 Bridges;
16:28:07;T +08:43;459;Safety is ensured;
16:28:13;T +08:49;460;Confirm to OPS that Safety is ensured;
16:28:24;T +09:00;461;BEGIN SEQUENCE: Data collection;
16:28:30;T +09:06;462;Turn off GoPro & Camcorder & Stop Block House Video recording;
16:28:38;T +09:14;463;Copy PID.vi.tdms & save to new name;
16:29:25;T +10:01;464;Wait for buffer storage process to be finished;
16:29:32;T +10:08;465;save data files from cRio to PC;
16:29:40;T +10:16;466;Save data on external HDD;
16:29:45;T +10:21;467;Stop TMTC Vi and save data on external HDD;
16:29:52;T +10:28;468;End audio recording;
16:29:58;T +10:34;469;Stop ComTerm and save logfile to external HDD, THEN...