diff --git a/AbortProcedure.csv b/AbortProcedure.csv index 2e85717..b9fe281 100644 --- a/AbortProcedure.csv +++ b/AbortProcedure.csv @@ -1,4 +1,4 @@ -vers.;v4.17;Abort Procedure;;3;;;;; +vers.;v4.18;Abort Procedure;;3;;;;; 0:00;MCC;Inform OPS of Launch Abort;;3;;;;; 0:00;MCC;BEGIN:Defueling Rocket;Defueling;3;;;;; 0:00;EGSE;Confirm all valve switches are in OFF position (Except OxDV & HPDV);;3;;;;; diff --git a/LaunchProcedure.csv b/LaunchProcedure.csv index 16dcce9..0108805 100644 --- a/LaunchProcedure.csv +++ b/LaunchProcedure.csv @@ -1,4 +1,4 @@ -vers.;v4.17;Launch Procedure;;0;MRL;MCC;RdHill;Time per step; +vers.;v4.18;Launch Procedure;;0;MRL;MCC;RdHill;Time per step; 147:20;WIND;Start wind weighting analysis;;1;;;;; 147:20;MCC;BEGIN SEQUENCE: Power on EGSE;Power on EGSE;1;;;;; 147:20;EGSE;Check CLD connection;;1;;;;; diff --git a/PassivationProcedure.csv b/PassivationProcedure.csv new file mode 100644 index 0000000..cd4cb62 --- /dev/null +++ b/PassivationProcedure.csv @@ -0,0 +1,46 @@ +vers.;v4.18;Passivation out of sequence Procedure;;2;;;;; +0:00;MCC/MRL;Recall and make sure N2O Bottles are still closed! Else continue with Abort Procedure;;2;;;;; +0:00;MCC;Inform OPS of Passivation out of sequence;;2;;;;; +0:00;MRL;Step Back/Leave MRL;;2;;;;; +0:00;EGSE;Confirm all valve switches are in OFF position (Except OxDV & HPDV);;2;;;;; +0:00;OBDH;Confirm all valve switches are in OFF position (Except RMOxSV);;2;;;;; +0:00;EGSE;Open & Close OxDV STEPWISE until OxOutPT 0 Bar;;2;;;;; +0:00;EGSE;Open OxDV;;2;;;;; +0:00;EGSE;Open MPV3;;2;;;;; +0:00;EGSE;Confirm OxOutPT 0 bar;;2;;;;; +0:00;EGSE;Close MPV3;;2;;;;; +0:00;EGSE;Open OxV1;;2;;;;; +0:00;EGSE;Confirm OxInPT1 & OxOutPT 0 Bar;;2;;;;; +0:00;EGSE;Close OxV1;;2;;;;; +0:00;EGSE;Open OxV2;;2;;;;; +0:00;EGSE;Confirm OxInPT2 & OxOutPT 0 Bar;;2;;;;; +0:00;EGSE;Close OxV2;;2;;;;; +0:00;EGSE;Close OxDV ;;2;;;;; +0:00;EGSE;Open HPDV;;2;;;;; +0:00;EGSE;Confirm HPLPT 0 bar;;2;;;;; +0:00;EGSE;Open HPV2;;2;;;;; +0:00;EGSE;Confirm HPLPT 0 bar;;2;;;;; +0:00;EGSE;Close HPDV;;2;;;;; +0:00;OBDH;Check RHPPT & ROxTPT 1 Bar (If more: continue with Passivation of Rocket, else continue with Passivation of GSE);;2;;;; +0:00;MCC;BEGIN:Passivation of Rocket;Passivation of Rocket;2;;;;; +0:00;OBDH;Open & Close stepwise RDV until RHPPT & ROxTPT 1 Bar;;2;;;;; +0:00;OBDH;Confirm RHPPT & ROxTPT 1 Bar;;2;;;;; +0:00;MRL;Go to MRL;;2;;;;; +0:00;MRL;Remove HP section maintenance cover;;2;;;;; +0:00;MRL;Open RMDV & Step Back, Wait until NCE-Tank is pressureless;;2;;;;; +0:00;MCC;BEGIN:Passivation of GSE;Passivation of GSE;2;;;;; +0:00;MRL;Close He Bottle 1;;2;;;;; +0:00;MCC/MRL;Write down remaining Pressure of He Bottle 1;;2;;;;; +0:00;MRL;Step back;;2;;;;; +0:00;EGSE;Open HPDV;;2;;;;; +0:00;EGSE;Open HPV1;;2;;;;; +0:00;EGSE;Confirm pressure HPLPT & HPPT1 0 Bar;;2;;;;; +0:00;EGSE;Close HPV1;;2;;;;; +0:00;EGSE;Close HPDV;;2;;;;; +0:00;EGSE;Pressure Check;;2;;;;; +0:00;MRL;Open MBV;;2;;;;; +0:00;EGSE/ MRL;Check and compare pressure HPPT1 with HPPG1;;2;;;;; +0:00;MRL;Close MBV;;2;;;;; +0:00;MRL;Safety is ensured;;2;;;;; +0:00;MCC;Confirm to OPS that Safety is ensured;;1;;;;; +0:00;MCC;END OF PROCEDURE;;1;;;;;