From 13276e7df3eff7b537c4a06ba35301b22cafda9a Mon Sep 17 00:00:00 2001 From: Finn Hansch Date: Sat, 6 Jun 2020 13:16:23 +0200 Subject: [PATCH] changes to maintenance cover closing (added RMDV) --- AbortProcedure.csv | 2 +- LaunchProcedure.csv | 25 +++++++++++++------------ PassivationProcedure.csv | 2 +- 3 files changed, 15 insertions(+), 14 deletions(-) diff --git a/AbortProcedure.csv b/AbortProcedure.csv index 7c92a46..ba96aeb 100644 --- a/AbortProcedure.csv +++ b/AbortProcedure.csv @@ -1,4 +1,4 @@ -vers.;v4.25;Abort Procedure;;3;mrl;mcc;rdh;time +vers.;v4.26;Abort Procedure;;3;mrl;mcc;rdh;time 0:00;MCC;BEGIN SEQUENCE: Defueling Rocket;Defueling;3;;;; 0:00;MCC;Inform OPS of Launch Abort;;3;;;; 0:00;EGSE;Confirm all valve switches are in OFF position (Except OxDV & HPDV);;3;;;; diff --git a/LaunchProcedure.csv b/LaunchProcedure.csv index 64b0139..80212a1 100644 --- a/LaunchProcedure.csv +++ b/LaunchProcedure.csv @@ -1,4 +1,4 @@ -vers.;v4.25;Launch Procedure;;0;MRL;MCC;RdHill;Time per step +vers.;v4.26;Launch Procedure;;0;MRL;MCC;RdHill;Time per step 147:20;MCC;BEGIN SEQUENCE: Power on EGSE;Power on EGSE;1;;;; 147:20;WIND;Start wind weighting analysis;;1;;;; 147:20;EGSE;Check CLD connection;;1;;;; @@ -149,10 +149,10 @@ vers.;v4.25;Launch Procedure;;0;MRL;MCC;RdHill;Time per step 105:00;EGSE/ MRL;Open & Close MPV3 SHORTLY;;2;;;; 0:00;MRL;Open HPNV1 completely;;2;;;; 0:00;MRL;Step Back;;2;;;; -0:00;EGSE;"Open & Close HPV1 STEPWISE untile HPLPT equal to HPPT1 and check for leakage @HPLPT (If leakage occurs continue with ""GSE Passivation Procedure"")";;2;;;; -0:00;EGSE;"Confirm RHPPT & RoxTPT 1 Bar (on Pressure continue with ""Rocket Passivation Procedure"")";;2;;;; +0:00;EGSE;"Open & Close HPV1 STEPWISE untile HPLPT equal to HPPT1 and check for leakage @HPLPT (If leakage occurs proceed to passivation Procedure out of sequence)";;2;;;; +0:00;EGSE;"Confirm RHPPT & RoxTPT 1 Bar (If pressure is higher proceed to passivation Procedure out of sequence);;2;;;; 0:00;EGSE;Open HPV1;;2;;;; -0:00;EGSE;"Open & Close HPV2 STEPWISE untile HPPT2 equal to HPLPT and check for leakage @HPPT2 (If leakage occurs continue with ""GSE Passivation Procedure"")";;2;;;; +0:00;EGSE;"Open & Close HPV2 STEPWISE untile HPPT2 equal to HPLPT and check for leakage @HPPT2 (If leakage occurs proceed to passivation Procedure out of sequence)";;2;;;; 0:00;EGSE;Close HPV1;;2;;;; 0:00;EGSE;Open HPDV & confirm HPLPT 0 Bar;;2;;;; 0:00;EGSE;Open HPV2 & confirm HPPT2 0 Bar;;2;;;; @@ -162,7 +162,7 @@ vers.;v4.25;Launch Procedure;;0;MRL;MCC;RdHill;Time per step 87:10;EGSE;Confirm MPV1/2 closed;;2;;;; 87:10;EGSE;Open OxDV;;2;;;; 87:10;EGSE;Open & Close STEPWISE MPV3 to 0 Bar @OxOutPT;;2;;;; -87:10;EGSE;Check OxInPT1 and OxInPT2 for leakage (If leakage occurs proceed to GSE passivation Procedure);;2;;;; +87:10;EGSE;Check OxInPT1 and OxInPT2 for leakage (If leakage occurs proceed to passivation Procedure out of sequence);;2;;;; 87:10;EGSE;Confirm MPV3 closed;;2;;;; 87:10;EGSE;Open & Close STEPWISE OxV1 to 0 Bar @OxInPT1;;2;;;; 87:10;EGSE;Open & Close STEPWISE OxV2 to 0 Bar @OxInPT2;;2;;;; @@ -173,12 +173,10 @@ vers.;v4.25;Launch Procedure;;0;MRL;MCC;RdHill;Time per step 103:30;EGSE;Decouple Helium coupling;;2;;;;00:20 103:10;EGSE;Move arm away from rocket;;2;;;; 103:10;EGSE;Move arm to rocket;;2;;;;01:00 -102:10;MRL;Close He Bottle 1 and check HPSM for leakage (If leakage occurs continue with Passivation Procedure);;2;;;;01:00 +102:10;MRL;Close He Bottle 1 and check HPSM for leakage (If leakage occurs proceed to passivation Procedure out of sequence);;2;;;;01:00 101:10;MRL;Open MBV;;2;;;; 101:10;EGSE/ MRL;Check and compare pressure HPPT1 with HPPG1 0 Bar;;2;;;; 101:10;MRL;Close MBV;;2;;;;00:30 -100:40;MRL;Open RMDV & relief pressure;;2;;;; -100:40;MRL;Close RMDV;;2;;;; 100:40;MRL;Safety is ensured;;2;;;; 100:40;MCC;EGSE @MRL to MRL;;1;;;; 100:40;EGSE;Switch OFF N20 coupling;;1;;;; @@ -206,15 +204,18 @@ vers.;v4.25;Launch Procedure;;0;MRL;MCC;RdHill;Time per step 99:00;OBDH;Disable RNCEV;;2;;;;00:10 99:20;EGSE;Turn ON EPS_BAT (Rocket OFF);;2;;;;01:00 99:20;MRL;Confirm working personel is grounded;;2;;;;01:00 -110:00;MRL;Confirm that HP maintenance cover is closed & secured;;2;;;;01:00 -110:00;MRL;Confirm that MainOX maintenance cover is closed & secured;;2;;;;01:00 -99:20;MRL;Confirm spring retracted cover at He coupling is moving freely;;2;;;; -99:20;MRL;Confirm spring retracted cover at N2O coupling is moving freely;;2;;;; +99:20;MRL;Confirm that RMDV is closed;;2;;;;01:00 +99:00;MRL;Close & secure HP maintenance cover;;2;;;;01:00 +99:00;MRL;Close & secure MainOX maintenance cover;;2;;;;01:00 98:50;MRL;Turn on GoPro Camera at end of Launch Rail;;2;;;;00:20 99:20;MRL;Connect Ignition Umbilical;;2;;;;00:30 98:30;MRL;Insert all EPS Bridges;;2;;;;03:00 95:30;MRL;Close bridge maintenance cover;;2;;;;00:20 +99:20;MRL;Confirm spring retracted cover at He coupling is moving freely;;2;;;; +99:20;MRL;Confirm spring retracted cover at N2O coupling is moving freely;;2;;;; +95:00;MRL;Confirm that HP maintenance cover is closed & secured;;2;;;;01:00 95:30;MRL;Confirm bridge maintenance cover is closed & secured;;2;;;;00:20 +95:00;MRL;Confirm that MainOX maintenance cover is closed & secured;;2;;;;01:00 95:10;EGSE @MRL;return to MCC;;2;;;; 95:10;OPS;Elevate MRL to 90 degrees;;2;;;;05:00 89:40;EGSE;Zero OxTank Mass;;2;;;;01:00 diff --git a/PassivationProcedure.csv b/PassivationProcedure.csv index 19dfd9f..2d8ee3b 100644 --- a/PassivationProcedure.csv +++ b/PassivationProcedure.csv @@ -1,4 +1,4 @@ -vers.;v4.25;Passivation out of sequence Procedure;;2;mrl;mcc;rdh;time +vers.;v4.26;Passivation out of sequence Procedure;;2;mrl;mcc;rdh;time 0:00;MCC;BEGIN SEQUENCE: Prepare Passivation Sequence;Prepare Passivation;2;;;; 0:00;MCC/MRL;Recall and make sure BOTH N2O Bottles & He Bottle 2 are still closed! Else continue with Abort Procedure;;2;;;; 0:00;MCC;Inform OPS of Passivation out of sequence;;2;;;;