added Windchecks & added rocket valve checks before fueling
This commit is contained in:
parent
f9718518e3
commit
585dd96d6b
|
@ -1,4 +1,5 @@
|
|||
vers.;v4.9;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
|
||||
vers.;v4.10;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
|
||||
147:20;WIND;Start wind weighting analysis;;1;;;;;
|
||||
147:20;MCC;BEGIN SEQUENCE: Power on EGSE;Power on EGSE;1;;;;;
|
||||
147:20;EGSE;Check CLD connection;;1;;;;;
|
||||
147:20;EGSE;Switch ON CLD via Battery & check voltage (24 Volt);;1;;;;;
|
||||
|
@ -39,6 +40,7 @@ vers.;v4.9;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
|
|||
139:50;OBDH;Confirm Main Chute button is disabled;;1;;;;;
|
||||
139:50;EGSE@MRL;Insert Payload Fuse;;1;;;;;
|
||||
139:50;EGSE@MRL;Confirm green LED at Payload Fuse is on;;1;;;;;
|
||||
139:50;WIND;Report on weather situation;;1;;;;;
|
||||
139:50;MCC;BEGIN SEQUENCE: Connect Fueling arm;Connect Fueling Arm;1;;;;;
|
||||
139:50;MRL;Confirm working personel is grounded;;1;;;;01:00;
|
||||
139:50;MRL;Confirm PPG 0 bar;;1;;;;;
|
||||
|
@ -177,6 +179,8 @@ vers.;v4.9;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
|
|||
101:10;MRL;Open MBV;;2;;;;;
|
||||
101:10;EGSE/MRL;Check and compare pressure HPPT1 with HPPG1 0 Bar;;2;;;;;
|
||||
101:10;MRL;Close MBV;;2;;;;00:30;
|
||||
100:40;MRL;Open RMDV & relief pressure;;2;;;;;
|
||||
100:40;MRL;Close RMDV;;2;;;;;
|
||||
100:40;MRL;Safety is ensured;;2;;;;;
|
||||
100:40;MCC;EGSE@MRL to MRL;;1;;;;;
|
||||
100:40;EGSE;Switch OFF N20 coupling;;1;;;;;
|
||||
|
@ -210,6 +214,11 @@ vers.;v4.9;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
|
|||
88:40;MCC;BEGIN SEQUENCE: Fueling Preparations (PHASE YELLOW);Fueling Preparations;2;;;;;
|
||||
130:50;EGSE/MRL;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;;1;;;;00:10;
|
||||
130:40;EGSE/MRL;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;1;;;;00:10;
|
||||
127:40;OBDH;Check RDV;;1;;;;00:10;
|
||||
127:30;OBDH;Check RNCEV;;1;;;;00:10;
|
||||
127:20;OBDH;Check RMOxOV;;1;;;;00:10;
|
||||
127:10;OBDH;Check RMOxSV;;1;;;;00:10;
|
||||
127:00;OBDH;Confirm RNCEV is disabled;;1;;;;00:10;
|
||||
88:40;MRL;Put on safety equipment;;2;;;;00:30;
|
||||
10:10;MRL;Confirm HPNV1 is Open;;2;;;;;
|
||||
10:10;MRL;Confirm HPNV2 is Closed;;2;;;;;
|
||||
|
@ -241,6 +250,7 @@ vers.;v4.9;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
|
|||
78:40;MRL;Close ComTerm & Go to Block House;;2;;;;;
|
||||
78:40;MCC;Turn OFF MRL confirm lock;;2;;;;;
|
||||
78:40;ALL;Inform OPS to clear Launch Pad (Tel.: [!!!]);;2;;;;2:00;
|
||||
147:20;WIND;Start wind weighting analysis;;1;;;;;
|
||||
130:50;EGSE/MRL;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;;1;;;;00:10;
|
||||
130:40;EGSE/MRL;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;1;;;;00:10;
|
||||
68:40;MCC;HOLD;HOLD;2;;;;;
|
||||
|
@ -250,6 +260,7 @@ vers.;v4.9;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
|
|||
130:40;EGSE/MRL;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;1;;;;00:10;
|
||||
130:40;EGSE;Confirm storage capacity of CRio is greater than [!!!];;1;;;;00:10;
|
||||
68:40;MCC;BEGIN SEQUENCE Ox Fueling (PHASE RED);Ox Fueling (PHASE RED);3;;;;;
|
||||
68:50;WIND;Report on weather situation;;1;;;;;
|
||||
68:40;MCC;Announce end of Radio Silence;;3;;;;;
|
||||
68:40;EGSE;Turn OFF EPS_BAT;;3;;;;;
|
||||
126:50;OBDH/TMTC;Check RF451-Link;;1;;;;00:20;
|
||||
|
@ -294,6 +305,7 @@ vers.;v4.9;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
|
|||
9:50;EGSE;Check OxOutPT 0 Bar;;3;;;;;
|
||||
9:50;EGSE;Decouple N2O coupling;;3;;;;00:20;
|
||||
9:30;MCC;Confirm End of Oxidator Fueling to OPS;;3;;;;00:15;
|
||||
9:20;WIND;Start wind weighting analysis;;1;;;;;
|
||||
9:15;OBDH/TMTC;Check RF451-Link;;3;;;;00:20;
|
||||
8:55;TMTC;Check GPS-lock;;3;;;;00:20;
|
||||
8:35;TMTC;Check Telemega-Link;;3;;;;00:20;
|
||||
|
@ -304,8 +316,9 @@ vers.;v4.9;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
|
|||
8:15;MCC;Turn OFF ComTerm step delay;;3;;;;;
|
||||
8:15;ALL;Talk through Ignition Sequence;;3;;;;;
|
||||
8:15;MCC;Wait for OPS to confirm final MRL adjustment;;3;;;;;
|
||||
8:15;AVC;Start Video recording in Block House;;3;;;;;
|
||||
8:15;WIND;Report on weather situation;;1;;;;;
|
||||
8:15;MCC;CONTINUE AFTER HOLD;;;;;;;
|
||||
8:15;AVC;Start Video recording in Block House;;3;;;;;
|
||||
8:15;EGSE;Verify He Bottle 2 Temperature @HPT2 & @HPWT2 (turn ON/OFF He_Heater if necessary) ;;1;;;;00:10;
|
||||
8:15;MCC;BEGIN SEQUENCE: Switching to Internal Power Sequence;Switch to Internal Power;3;;;;;
|
||||
8:15;EGSE;Turn OFF EPS_Ext (Switch to internal Power);;3;;;;00:20;
|
||||
|
|