diff --git a/AbortProcedure.csv b/AbortProcedure.csv index 0fdaaf0..4784021 100644 --- a/AbortProcedure.csv +++ b/AbortProcedure.csv @@ -1,48 +1,72 @@ -vers.;v2.4;Abort Procedure;;3 -0;ALL;BEGIN ABORT PROCEDURE;;3 -0;EGSE;Confirm all valve switches are in OFF position (Except OxDV & HPDV);;3 -0;OBDH;Confirm all valve switches are in OFF position (Except RMOxSV);;3 -0;EGSE;Open OxDV stepwise;;3 -0;EGSE;Open MPV3;;3 -0;EGSE;Check OxOutPT 0 bar;;3 -0;EGSE;Close MPV3;;3 -0;EGSE;Close OxDV;;3 -0;EGSE;Check OxOutPT 0 bar;;3 -0;EGSE;Open HPDV;;3 -0;EGSE;Check HPLPT 0 bar;;3 -0;EGSE;Close HPDV;;3 -0;OBDH;Check ROxTPT & RHPPT 1 Bar, if more: Open & Close stepwise RDV;;3 -0;OBDH;Deactivate Heizi;;2 -0;MRL;Go to MRL;;2 -0;MRL;Close N2O Bottle 1 & N2O Bottle 2;;2 -0;MRL;Go to BlockHouse;;2 -0;EGSE;Open OxDV;;2 -0;EGSE;Open OxV1;;2 -0;EGSE;Check OxInPT1 & OxOutPT 0 Bar;;2 -0;EGSE;Close OxV1;;2 -0;EGSE;Open OxV2;;2 -0;EGSE;Check OxInPT2 & OxOutPT 0 Bar;;2 -0;EGSE;Close OxV2;;2 -0;EGSE;Close OxDV ;;2 -0;MRL;Go to MRL;;2 -0;MRL;Confirm OxInPG1 & OxInPG2 0 Bar;;2 -0;MRL;Close HE Bottle;;2 -0;MRL;Write down remaining Pressure of HE Bottle;;2 -0;MRL;Go to BlockHouse;;2 -0;EGSE;Open HPDV;;2 -0;EGSE;Open HPV2;;2 -0;EGSE;Check pressure HPLPT & HPPT2 0 Bar;;2 -0;EGSE;Close HPV2;;2 -0;EGSE;Close HPDV;;2 -0;MRL;Go to MRL;;2 -0;MRL;Confirm HPPG2 0 Bar;;2 -0;MRL;Close N2 Bottle;;2 -0;MRL;Write down remaining Pressure of N2 Bottle;;2 -0;MRL;Step back;;2 -0;MRL;Open MBV;;2 -0;EGSE;Check and compare pressure HPPT1 with HPPG1;;2 -0;MRL;Close MBV;;2 -0;MRL;Disconnect Zündi;;2 -0;MRL;Safety is ensured;;2 -0;MCC;Turn off area warning light and open barrier;;1 +vers.;v4.16;Abort Procedure;;3;;;;; +0:00;MCC;Inform OPS of Launch Abort;;3;;;;; +0:00;MCC;BEGIN:Defueling Rocket;Defueling;3;;;;; +0:00;EGSE;Confirm all valve switches are in OFF position (Except OxDV & HPDV);;3 +0:00;OBDH;Confirm all valve switches are in OFF position (Except RMOxSV);;3 +0:00;OBDH;Activate Heizi;;3;;;;; +0:00;MCC;Turn audio volume up;;2;;;;; +0:00;EGSE;Open & Close OxDV STEPWISE until OxOutPT 0 Bar;;3 +0:00;EGSE;Open OxDV;;3 +0:00;EGSE;Open MPV3;;3 +0:00;EGSE;Confirm OxOutPT 0 bar;;3 +0:00;EGSE;Close MPV3;;3 +0:00;EGSE;Close OxDV;;3 +0:00;EGSE;Open HPDV;;3 +0:00;EGSE;Confirm HPLPT 0 bar;;3 +0:00;EGSE;Close HPDV;;3 +0:00;OBDH;Confirm ROxTPT & RHPPT 1 Bar, if more: Open & Close stepwise RDV;;3 +0:00;OBDH;Deactivate Heizi;;3 +0:00;ALL;Wait for Launchpad to be clear of N2O fumes depending on OxMass before Defueling;;3;;;;; +0:00;MCC;BEGIN: ground segment passivation;GSE Passivation;3;;;;; +0:00;MCC;Announce BEGIN of Radio Silence;;3;;;;; +0:00;MRL;Go to MRL, Close N2O Bottle 1 & N2O Bottle 2, THEN...;;2;;;;; +0:00;MRL;RETURN to Block House;;2;;;;; +0:00;EGSE;Open OxDV;;2;;;;; +0:00;EGSE;Open OxV1;;2;;;;; +0:00;EGSE;Confirm OxInPT1 & OxOutPT 0 Bar;;2;;;;; +0:00;EGSE;Close OxV1;;2;;;;; +0:00;EGSE;Open OxV2;;2;;;;; +0:00;EGSE;Confirm OxInPT2 & OxOutPT 0 Bar;;2;;;;; +0:00;EGSE;Close OxV2;;2;;;;; +0:00;EGSE;Close OxDV ;;2;;;;; +0:00;MRL;Go to MRL, confirm OxInPG1 & OxInPG2 0 Bar, else RETURN to Block House, THEN... +0:00;MRL;Close He Bottle 2, THEN...;;2;;;;; +0:00;MRL;Write down remaining Pressure of He Bottle 2, THEN...;;2;;;;; +0:00;MRL;Return to Block House;;2;;;;; +0:00;EGSE;Open HPDV;;2;;;;; +0:00;EGSE;Open HPV2;;2;;;;; +0:00;EGSE;Confirm pressure HPLPT & HPPT2 0 Bar;;2;;;;; +0:00;EGSE;Close HPV2;;2;;;;; +0:00;EGSE;Close HPDV;;2;;;;; +0:00;MRL;Go to Testrig, confirm HPPG2 0 Bar, else return to Block House, THEN...;;2;;;;; +0:00;MRL;Close He Bottle 1, THEN ...;;2;;;;; +0:00;MRL;Open ComTerm;;2;;;;; +8:15;MCC;Turn ON ComTerm step delay;;3;;;;; +0:00;MCC/MRL;Write down remaining Pressure of He Bottle 1;;2;;;;; +0:00;MRL;Step back;;2;;;;; +0:00;EGSE;Open HPDV;;2;;;;; +0:00;EGSE;Open HPV1;;2;;;;; +0:00;EGSE;Confirm pressure HPLPT & HPPT1 0 Bar;;2;;;;; +0:00;EGSE;Close HPV1;;2;;;;; +0:00;EGSE;Close HPDV;;2;;;;; +0:00;EGSE;Pressure Check;;2;;;;; +0:00;MRL;Open MBV;;2;;;;; +0:00;EGSE/ MRL;Check and compare pressure HPPT1 with HPPG1;;2;;;;; +0:00;MRL;Close MBV;;2;;;;; +0:00;MRL;Take out Bridges B1 & B2 from EGSE;;2;;;;; +0:00;MRL;Disconnect Ignition Umbilical;;1;;;;00:30; +0:00;MRL;Safety is ensured;;2;;;;; +0:00;MCC;Confirm to OPS that Safety is ensured;;1;;;;; +0:00;MCC;BEGIN SEQUENCE: Data collection;Data collection;1;;;;; +0:00;AVC;Turn off GoPro & Camcorder & Stop Block House Video recording;;1;;;;; +0:00;EGSE;Copy PID.vi.tdms & save to new name;;1;;;;; +0:00;EGSE;Wait for buffer storage process to be finished;;1;;;;; +0:00;EGSE;save data files from cRio to PC;;1;;;;; +0:00;WIND;Save data on external HDD;;1;;;;; +0:00;TMTC;Stop TMTC Vi and save data on external HDD;;1;;;;; +0:00;AVC;End audio recording;;1;;;;; +0:00;MCC;Stop ComTerm and save logfile to external HDD, THEN...;;1;;;;; +0:00;MCC;Restart ComTerm VI;;1;;;;; +0:00;AVC;Save video & audio data on external HDD;;1;;;;; +0:00;MCC;END OF PROCEDURE;;1;;;;; 0;MCC;END OF ABORT Procedure (PHASE GREEN) (Write down Time);;1 diff --git a/LaunchProcedure.csv b/LaunchProcedure.csv index 5eca0b6..3c815a3 100644 --- a/LaunchProcedure.csv +++ b/LaunchProcedure.csv @@ -1,4 +1,4 @@ -vers.;v4.15;Launch Procedure;;0;MRL;MCC;RdHill;Time per step; +vers.;v4.16;Launch Procedure;;0;MRL;MCC;RdHill;Time per step; 147:20;WIND;Start wind weighting analysis;;1;;;;; 147:20;MCC;BEGIN SEQUENCE: Power on EGSE;Power on EGSE;1;;;;; 147:20;EGSE;Check CLD connection;;1;;;;; @@ -366,10 +366,10 @@ vers.;v4.15;Launch Procedure;;0;MRL;MCC;RdHill;Time per step; 0:00;OBDH;T+50: Verify RNCEV Open (Drogue);;4;;;;; 0:00;OBDH;T+310: Verify Main Chute Deployed and RDV Open (Main);;4;;;;; 0:00;OBDH;T+600: Verify (Landed);;4;;;;; -0:00;MCC;BEGIN SEQUENCE: PASSIVATION (PHASE YELLOW) (Write down Time);Passivation;2;;;;; +0:00;MCC;BEGIN SEQUENCE: PASSIVATION (PHASE YELLOW);Passivation;2;;;;; 68:40;MCC;Announce BEGIN of Radio Silence;;3;;;;; 0:00;MCC;Turn audio volume up;;2;;;;; -0:00;MRL;Go to MRL, Close N2O Bottle 1 & N2O Bottle 2, THEN... RETURN to Block House;;2;;;;; +0:00;MRL;Go to MRL, Close N2O Bottle 1 & N2O Bottle 2, THEN...;;2;;;;; 0:00;MRL;RETURN to Block House;;2;;;;; 0:00;EGSE;Open OxDV;;2;;;;; 0:00;EGSE;Open OxV1;;2;;;;; @@ -391,7 +391,7 @@ vers.;v4.15;Launch Procedure;;0;MRL;MCC;RdHill;Time per step; 0:00;MRL;Go to Testrig, confirm HPPG2 0 Bar, else return to Block House, THEN...;;2;;;;; 0:00;MRL;Close He Bottle 1, THEN ...;;2;;;;; 0:00;MRL;Open ComTerm;;2;;;;; -0:00;MCC;Turn on MRL lock;;2;;;;; +8:15;MCC;Turn ON ComTerm step delay;;3;;;;; 0:00;MRL;Write down remaining Pressure of He Bottle 1;;2;;;;; 0:00;MRL;Step back;;2;;;;; 0:00;EGSE;Open HPDV;;2;;;;;