vers.;v3.0;Launch Procedure;;0;MRL;MCC;RdHill;Time per step; vers.;v3.2;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
147:20;EGSE;BEGIN of Power on EGSE Sequence;Power on EGSE;1;;;;; 147:20;EGSE;BEGIN of Power on EGSE Sequence;Power on EGSE;1;;;;;
147:20;EGSE;Check CLD connection;;1;;;;; 147:20;EGSE;Check CLD connection;;1;;;;;
147:20;EGSE;Switch on CLD via Battery & check voltage (24 Volt);;1;;;;; 147:20;EGSE;Switch on CLD via Battery & check voltage (24 Volt);;1;;;;;
@ -230,7 +230,7 @@ vers.;v3.0;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
8:15;ALL;Align MRL to Launch Trajectory;;3;;;;; 8:15;ALL;Align MRL to Launch Trajectory;;3;;;;;
8:15;MCC;Confirm MRL adjustment is final;;3;;;;; 8:15;MCC;Confirm MRL adjustment is final;;3;;;;;
8:15;ALL;Talk through Launch Sequence;;3;;;;; 8:15;ALL;Talk through Launch Sequence;;3;;;;;
8:15;AVC;Start Video Recording in BlockHouse;;3;;;;; 8:15;AVC;Start Video Recording in Block House;;3;;;;;
8:15;MCC;Turn audio volume down;;3;;;;; 8:15;MCC;Turn audio volume down;;3;;;;;
8:15;MCC;CONTINUE AFTER HOLD;;;;;;; 8:15;MCC;CONTINUE AFTER HOLD;;;;;;;
8:15;MCC;BEGIN Switching to Internal Power Sequence;Switch to Internal Power;3;;;;; 8:15;MCC;BEGIN Switching to Internal Power Sequence;Switch to Internal Power;3;;;;;
@ -279,7 +279,7 @@ vers.;v3.0;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
0:00;MCC;START OF PASSIVATION (PHASE YELLOW) (Write down Time);Passivation;2;;;;; 0:00;MCC;START OF PASSIVATION (PHASE YELLOW) (Write down Time);Passivation;2;;;;;
0:00;MCC;Turn audio volume up;;2;;;;; 0:00;MCC;Turn audio volume up;;2;;;;;
0:00;TMTC;Check ROxTPT & RHPPT 1 Bar, if more: Open & Close stepwise RDV;;2;;;;; 0:00;TMTC;Check ROxTPT & RHPPT 1 Bar, if more: Open & Close stepwise RDV;;2;;;;;
0:00;MRL;Go to Testrig, close N2O Bottle 1 & N2O Bottle 2 and return to BlockHouse;;2;;;;; 0:00;MRL;Go to Testrig, close N2O Bottle 1 & N2O Bottle 2 and return to Block House;;2;;;;;
0:00;EGSE;Open OxDV;;2;;;;; 0:00;EGSE;Open OxDV;;2;;;;;
0:00;EGSE;Open OxV1;;2;;;;; 0:00;EGSE;Open OxV1;;2;;;;;
0:00;EGSE;Check OxInPT1 & OxOutPT 0 Bar;;2;;;;; 0:00;EGSE;Check OxInPT1 & OxOutPT 0 Bar;;2;;;;;
@ -288,16 +288,16 @@ vers.;v3.0;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
0:00;EGSE;Check OxInPT2 & OxOutPT 0 Bar;;2;;;;; 0:00;EGSE;Check OxInPT2 & OxOutPT 0 Bar;;2;;;;;
0:00;EGSE;Close OxV2;;2;;;;; 0:00;EGSE;Close OxV2;;2;;;;;
0:00;EGSE;Close OxDV ;;2;;;;; 0:00;EGSE;Close OxDV ;;2;;;;;
0:00;MRL;Go to MRL, confirm OxInPG1 & OxInPG2 0 Bar, else return to BlockHouse, then close HE Bottle;;2;;;;; 0:00;MRL;Go to MRL, confirm OxInPG1 & OxInPG2 0 Bar, else return to Block House, then close HE Bottle;;2;;;;;
0:00;MRL;Write down remaining Pressure of HE Bottle;;2;;;;; 0:00;MRL;Write down remaining Pressure of HE Bottle;;2;;;;;
0:00;EGSE;Open HPDV;;2;;;;; 0:00;EGSE;Open HPDV;;2;;;;;
0:00;EGSE;Open HPV2;;2;;;;; 0:00;EGSE;Open HPV2;;2;;;;;
0:00;EGSE;Check pressure HPLPT & HPPT2 0 Bar;;2;;;;; 0:00;EGSE;Check pressure HPLPT & HPPT2 0 Bar;;2;;;;;
0:00;EGSE;Close HPV2;;2;;;;; 0:00;EGSE;Close HPV2;;2;;;;;
0:00;EGSE;Close HPDV;;2;;;;; 0:00;EGSE;Close HPDV;;2;;;;;
0:00;MRL;Go to Testrig, confirm HPPG2 0 Bar, else return to BlockHouse, then open ComTerm;;2;;;;; 0:00;MRL;Go to Testrig, confirm HPPG2 0 Bar, else return to Block House, then open ComTerm;;2;;;;;
0:00;MRL;Close N2 Bottle;;2;;;;; 0:00;MRL;Close HE Bottle;;2;;;;;
0:00;MRL;Write down remaining Pressure of N2 Bottle;;2;;;;; 0:00;MRL;Write down remaining Pressure of HE Bottle;;2;;;;;
0:00;MRL;Step back;;2;;;;; 0:00;MRL;Step back;;2;;;;;
0:00;MRL;Check EPV manometer less than 6 bar;;2;;;;; 0:00;MRL;Check EPV manometer less than 6 bar;;2;;;;;
0:00;MRL;Open MBV;;2;;;;; 0:00;MRL;Open MBV;;2;;;;;
@ -308,7 +308,7 @@ vers.;v3.0;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
0:00;MCC;Turn off area warning light and open barrier;;1;;;;; 0:00;MCC;Turn off area warning light and open barrier;;1;;;;;
0:00;MCC;END OF PASSIVATION (PHASE GREEN) (Write down Time);;1;;;;; 0:00;MCC;END OF PASSIVATION (PHASE GREEN) (Write down Time);;1;;;;;
0:00;MCC;START DATA COLLECTION (Write down Time);Collection;1;;;;; 0:00;MCC;START DATA COLLECTION (Write down Time);Collection;1;;;;;
0:00;AVC;Turn off GoPro & Camcorder & Stop BlockHouse Video recording;;1;;;;; 0:00;AVC;Turn off GoPro & Camcorder & Stop Block House Video recording;;1;;;;;
0:00;EGSE;Copy PID.vi.tdms & save to new name;;1;;;;; 0:00;EGSE;Copy PID.vi.tdms & save to new name;;1;;;;;
0:00;EGSE;Wait for buffer storage process to be finished;;1;;;;; 0:00;EGSE;Wait for buffer storage process to be finished;;1;;;;;
0:00;EGSE;save data files from cRIO to PC;;1;;;;; 0:00;EGSE;save data files from cRIO to PC;;1;;;;;

1 vers. v3.0 v3.2 Launch Procedure 0 MRL MCC RdHill Time per step
2 147:20 EGSE BEGIN of Power on EGSE Sequence Power on EGSE 1
3 147:20 EGSE Check CLD connection 1
4 147:20 EGSE Switch on CLD via Battery & check voltage (24 Volt) 1
230 8:15 ALL Align MRL to Launch Trajectory 3
231 8:15 MCC Confirm MRL adjustment is final 3
232 8:15 ALL Talk through Launch Sequence 3
233 8:15 AVC Start Video Recording in BlockHouse Start Video Recording in Block House 3
234 8:15 MCC Turn audio volume down 3
235 8:15 MCC CONTINUE AFTER HOLD
236 8:15 MCC BEGIN Switching to Internal Power Sequence Switch to Internal Power 3
279 0:00 MCC START OF PASSIVATION (PHASE YELLOW) (Write down Time) Passivation 2
280 0:00 MCC Turn audio volume up 2
281 0:00 TMTC Check ROxTPT & RHPPT 1 Bar, if more: Open & Close stepwise RDV 2
282 0:00 MRL Go to Testrig, close N2O Bottle 1 & N2O Bottle 2 and return to BlockHouse Go to Testrig, close N2O Bottle 1 & N2O Bottle 2 and return to Block House 2
283 0:00 EGSE Open OxDV 2
284 0:00 EGSE Open OxV1 2
285 0:00 EGSE Check OxInPT1 & OxOutPT 0 Bar 2
288 0:00 EGSE Check OxInPT2 & OxOutPT 0 Bar 2
289 0:00 EGSE Close OxV2 2
290 0:00 EGSE Close OxDV 2
291 0:00 MRL Go to MRL, confirm OxInPG1 & OxInPG2 0 Bar, else return to BlockHouse, then close HE Bottle Go to MRL, confirm OxInPG1 & OxInPG2 0 Bar, else return to Block House, then close HE Bottle 2
292 0:00 MRL Write down remaining Pressure of HE Bottle 2
293 0:00 EGSE Open HPDV 2
294 0:00 EGSE Open HPV2 2
295 0:00 EGSE Check pressure HPLPT & HPPT2 0 Bar 2
296 0:00 EGSE Close HPV2 2
297 0:00 EGSE Close HPDV 2
298 0:00 MRL Go to Testrig, confirm HPPG2 0 Bar, else return to BlockHouse, then open ComTerm Go to Testrig, confirm HPPG2 0 Bar, else return to Block House, then open ComTerm 2
299 0:00 MRL Close N2 Bottle Close HE Bottle 2
300 0:00 MRL Write down remaining Pressure of N2 Bottle Write down remaining Pressure of HE Bottle 2
301 0:00 MRL Step back 2
302 0:00 MRL Check EPV manometer less than 6 bar 2
303 0:00 MRL Open MBV 2
308 0:00 MCC Turn off area warning light and open barrier 1
309 0:00 MCC END OF PASSIVATION (PHASE GREEN) (Write down Time) 1
310 0:00 MCC START DATA COLLECTION (Write down Time) Collection 1
311 0:00 AVC Turn off GoPro & Camcorder & Stop BlockHouse Video recording Turn off GoPro & Camcorder & Stop Block House Video recording 1
312 0:00 EGSE Copy PID.vi.tdms & save to new name 1
313 0:00 EGSE Wait for buffer storage process to be finished 1
314 0:00 EGSE save data files from cRIO to PC 1