diff --git a/LaunchProcedure.csv b/LaunchProcedure.csv index e3f8b45..74f94b2 100644 --- a/LaunchProcedure.csv +++ b/LaunchProcedure.csv @@ -1,320 +1,319 @@ vers.;v3.0;Launch Procedure;;0;MRL;MCC;RdHill;Time per step; -147:35;EGSE;BEGIN of Power on EGSE Sequence;Power on EGSE;1;;;;; -148:35;EGSE;Check CLD connection;;1;;;;; -148:35;EGSE;Switch on CLD via Battery & check voltage (24 Volt);;1;;;;; -148:35;EGSE;Switch on the primary and secondary supply switches on the Control Panel;;1;;;;01:00; -147:35;EGSE@MRL;Switch on Sup_24V_20A & check voltage (ca. 27,2 Volt);;1;;;;; -147:35;EGSE@MRL;Switch on Sup_24V_10A & check voltage (ca. 27,2 Volt);;1;;;;; -147:35;EGSE@MRL;Switch on Sup_12V_10A & check voltage (ca. 13,8 Volt);;1;;;;; -147:35;EGSE@MRL;Switch on Bat_24V_20A & check voltage (ca. 27,9 Volt);;1;;;;; -147:35;EGSE@MRL;Switch on Bat_24V_10A & check voltage (ca. 27,9 Volt);;1;;;;; -147:35;EGSE@MRL;Switch on Bat_12V_10A & check voltage (ca. 13,8 Volt);;1;;;;; -147:35;EGSE@MRL;Switch on Sup_24V_40A;;1;;;;; -147:35;EGSE@MRL;Switch on Sup_5V_10A;;1;;;;03:00; -144:35;EGSE;Connect to cRIO;;1;;;;; -144:35;EGSE;Start FPGA_VI;;1;;;;; -144:35;EGSE;Start RT_VI;;1;;;;; -144:35;EGSE;Confirm PID-VI is running;;1;;;;; -144:35;EGSE;Rename PID-Logfile;;1;;;;02:00; -142:35;MRL;Confirm working Personel is grounded;;1;;;;; -0;EGSL@MRL;Confirm all 8 Groundingbridges are inserted;;1;;;;; -142:35;MRL;Connect Data Umbilical;Connect Data Umbilical;1;;;;00:30; -0;EGSE;Turn on EPS_BAT;;1;;;;; -0;EGSE;Turn on EPS_EXT;;1;;;;; -0;EGSE@MRL;Remove 7 Grounding Bridges and leave EPS_BAT inserted;;1;;;;; -0;EGSE@MRL;Insert EPS_EXT Fuse in Power Supply Control Panel;;1;;;;; -0;EGSE@MRL;Confirm green LED at EPS_EXT Fuse is on;;1;;;;; -0;EGSE@MRL;Insert Main_Bus Fuse in Power Supply Control Panel;;1;;;;; -0;EGSE@MRL;Confirm LED at Main_Bus Fuse is OFF. Else Pull fuse and insert all Grounding Bridges;;1;;;;; -0;EGSE@MRL;Set remaining Fuses (except Payload Fuse) and check for green LED;;1;;;;; -0;EGSE;Turn OFF EPS_BAT;;1;;;;; -0;EGSE@MRL;Confirm Main bus LED is on.;;1;;;;; -142:05;EGSE;Start EPS via EPS_ext;;1;;;;; -140:05;OBDH;Clear SD-Card-using FileZilla FTP;;;;;;01:00; -139:05;OBDH;Connect to sbRIO;;1;;;;; -139:05;OBDH;Start RT_Main;;1;;;;; -139:05;MRL;Confirm 3 beeps at OBC1;;1;;;;; -139:05;OBDH;Open RT_Sub_HMI;;1;;;;; -139:05;OBDH;Confirm Main Chute button is disabled;;1;;;;; -0;EGSE@MRL;Insert Payload Fuse -0;EGSE@MRL;Confirm green LED at Payload Fuse is on -139:05;MRL;Confirm working Personel is grounded;;1;;;;01:00; -138:05;MRL;Remove Pneumatic Line from Fueling arm;;1;;;;; -138:05;MRL;Move Fueling arm to rocket;;1;;;;; -138:05;MRL;Couple Helium coupling;;1;;;;; -138:05;MRL;Couple N2O coupling;;1;;;;; -138:05;MRL;Reattach Pneumatic Line to Fueling arm;;1;;;;03:00; -135:05;MRL;Confirm that Ignition Umbilical is disconnected;;1;;;;; -135:05;EGSE;BEGIN EGSE Valve and actuator check Sequence;Valve check;1;;;;; -135:05;MCC;Check if video recording is enabled @ MCC;;1;;;;00:10; -134:55;OBDH;Check EPS hardware Voltages;;1;;;;00:10; -134:45;EGSE;Start PID data recording;;1;;;;00:10; -134:25;MRL;Close HPNV;;1;;;;00:10; -134:15;EGSE/MRL;Switch OxDV to closed & check if magnetic valve LED is on;;1;;;;00:10; -134:05;EGSE/MRL;Switch HPDV to closed & check if magnetic valve LED is on;;1;;;;00:10; -133:55;EGSE/MRL;Check warning lamp on HPSM;;1;;;;00:10; -133:45;MRL;Remove loose equipment;;1;;;;03:00; -130:45;EGSE;Activate Heizi;;1;;;;00:10; -130:35;EGSE;Activate N2O_Heater 1;;1;;;;00:10; -130:25;EGSE;Activate N2O_Heater 2;;1;;;;00:10; -130:15;EGSE;Activate HE_Heater;;1;;;;00:10; -128:15;OBDH;Verify Heizi @ RDVT & RDVET;;1;;;;00:10; -128:35;EGSE/MRL;Verify Bottle Temperatures @ OxT1, OxT2, HPT2;;1;;;;00:10; -128:25;EGSE/MRL;Verify Water Temperatures @ Ox@T1, OxWT2, HPWT2;;1;;;;00:10; -128:05;EGSE;Deactivate Heizi;;1;;;;00:10; -130:05;EGSE;Check OxV1 (CLD & RT_VI);;1;;;;00:10; -129:55;EGSE;Check OxV2 (CLD & RT_VI);;1;;;;00:10; -129:45;EGSE;Check MPV3 (CLD & RT_VI);;1;;;;00:10; -129:35;EGSE;Check HPV1 (CLD & RT_VI);;1;;;;00:10; -129:25;EGSE;Check HPV2 (CLD & RT_VI);;1;;;;00:10; -129:15;EGSE;Check MPV1/2 (CLD & RT_VI);;1;;;;00:10; -129:05;EGSE;Check RDV (CLD & RT_VI);;1;;;;00:10; -128:55;EGSE;Check RMOxOV (CLD & RT_VI);;1;;;;00:10; -128:45;EGSE;Check RMOxSV (CLD & RT_VI);;1;;;;00:10; -127:55;OBDH;Activate Heizi;;1;;;;00:10; -126:55;OBDH;Verify Heizi @ RDVT & RDVET;;1;;;;01:00; -127:45;OBDH;Check RDV;;1;;;;00:10; -127:35;OBDH;Check RNCEV;;1;;;;00:10; -127:25;OBDH;Check RMOxOV;;1;;;;00:10; -127:15;OBDH;Check RMOxSV;;1;;;;00:10; -127:05;OBDH;Confirm RNCEV is disabled;;1;;;;00:10; -126:45;OBDH/TMTC;Check RF451-Link;;1;;;;00:20; -126:25;TMTC;Check GPS-lock;;3;;;;00:20; -126:05;TMTC;Check Telemega-Link;;1;;;;00:20; -125:45;OBDH;Test Connection to STX3;;1;;;;00:20; -125:25;OBDH;Check if STX3 Package received by email;;1;;;;00:30; -124:55;MRL;Check MBV closed;;1;;;;; -124:55;EGSE;Check if all valve switches are in OFF position (Except OxDV & HPDV);;1;;;;10:00; -114:55;MRL/EGSE;Check loadcell by applying force to it;;1;;;;00:20; -114:35;OBDH;Check RHPPT shows atmosphere;;1;;;;; -114:35;OBDH;Check ROxTPT shows atmosphere;;1;;;;; -114:35;OBDH;Check RIHPT shows atmosphere;;1;;;;; -114:35;OBDH;Check RCCPT shows atmosphere;;1;;;;; -114:35;OBDH;Check RBaro1 shows atmosphere;;1;;;;; -114:35;OBDH;Check RBaro2 shows atmosphere;;1;;;;; -114:35;EGSE;Check HPPT1 shows 0 bar;;1;;;;00:20; -114:15;EGSE;Check HPPT2 shows 0 bar;;1;;;;; -114:15;EGSE;Check HPLPT shows 0 bar;;1;;;;; -114:15;EGSE;Check OxInPT1 shows 0 bar;;1;;;;; -114:15;EGSE;Check OxInPT2 shows 0 bar;;1;;;;; -114:15;EGSE;Check OxOutPT shows 0 bar;;1;;;;00:20; -113:55;EGSE/MRL;Switch on N2O coupling & check if magnetic valve LED is on;;1;;;;; -113:55;EGSE/MRL;Switch on HE coupling & check if magnetic valve LED is on;;1;;;;; -113:55;EGSE/MRL;Switch on swivle arm & check if magnetic valve LED is on;;1;;;;; -113:55;EGSE;Switch off swivel arm & HE coupling & N2O coupling;;1;;;;01:00; -112:55;MRL;Confirm that Ignition Umbilical is disconnected;;1;;;;; -112:55;MRL;Connect Ignition test Receptical;;1;;;;; -112:55;EGSE@MRL;Plug in Bridges B1 and B2;;1;;;;; -112:55;MRL;Confirm Soundsignal from Ignition Umbilical;;2;;;;; -112:55;EGSE;Turn on Ignition Secure;;1;;;;; -112:55;EGSE/OBDH;Turn on Ignition Switch for 2 Second & Confirm ignition signal received at sbRio;;1;;;;; -112:55;EGSE;Turn off Ignition Secure;;1;;;;; -112:55;EGSE@MRL;Remove Bridges B1 and B2;;1;;;;; -112:55;MRL;Remove Ignition test Receptical;;1;;;;03:00; -109:55;MCC;Ground Segment Pressure Test (PHASE YELLOW) ;Ground Pressure Test;1;;;;; -109:55;MRL;Confirm that all hatches and covers are closed;;1;;;;01:00;all hatches -108:55;MRL;Check HE bottle 1 connector is attached;;1;;;;; -108:55;MRL;Check HE bottle 2 connector is attached;;1;;;;; -108:55;MRL;Check N2O bottle 1 connector is attached;;1;;;;; -108:55;MRL;Check N2O bottle 2 connector is attached;;1;;;;; -108:55;MRL;Check hose between HPSM & N2OSM is connected on both ends;;1;;;;; -108:55;MRL;Check hose between HPSM & Flight Segment is connected on both ends;;1;;;;; -108:55;MRL;Check hose between N2OSM & Flight Segment is connected on both ends;;1;;;;; -108:55;MRL;Check Pneumatik hose is connected on both ends;;1;;;;02:00; -106:55;MRL;Put on safety equipment;;2;;;;; -106:55;MRL;Move into Position to open HE Bottle 1;;2;;;;; -106:55;MRL;Check if HPV1 is closed;;2;;;;; -106:55;MRL;Check if MPV1/2 is closed;;2;;;;; -106:55;MRL;Open HE Bottle 1;;2;;;;01:00; -105:55;MRL;Check & compare pressure HPPT1 with HPPG1 (max 300 bar);;2;;;;; -105:55;MRL;Check Gastech Silver HPPR1 (max 300 to 50 bar);;2;;;;; -105:55;MRL;Check Harris PPR (50 to 8 bar);;2;;;;; -105:55;MRL;Check pneumatic PPG (8 bar);;2;;;;; -105:55;MRL;Step back;;2;;;;01:00; -104:55;EGSE;Confirm HPPT1 is at 300 Bar;;1;;;;;?? -104:55;EGSE;Confirm HPLPT less than 10 Bar;;1;;;;; -104:55;EGSE/MRL;Open & Close HPV1 SHORTLY & Check HPPT1;;2;;;;; -104:55;EGSE/MRL;Open & Close HPV2 SHORTLY & Check HPPT2 0 bar;;2;;;;; -104:55;EGSE/MRL;Open & Close HPDV SHORTLY & Check HPLPT 0 bar;;2;;;;; -104:55;EGSE/MRL;Open & Close OxV1 SHORTLY;;2;;;;; -104:55;EGSE/MRL;Open & Close OxV2 SHORTLY;;2;;;;; -104:55;EGSE/MRL;Open & Close OxDV SHORTLY;;2;;;;; -104:55;EGSE/MRL;Open & Close MPV3 SHORTLY;;2;;;;; -104:55;EGSE;Check HPLPT & OxOutPT 0 Bar;;2;;;;01:30; -103:25;EGSE;Decouple N2O coupling;;2;;;;; -103:25;EGSE;Decouple Helium coupling;;2;;;;00:20; -103:05;EGSE;Move arm away from rocket;;2;;;;; -103:05;EGSE;Move arm to rocket;;2;;;;01:00; -102:05;MRL;Close HE Bottle 1 and check HPSM for leakage (If leakage occurs Abort);;2;;;;01:00; -101:05;MRL;Open HPNV 1/8 Rev;;2;;;;; -101:05;MRL;Open MBV;;2;;;;; -101:05;EGSE/MRL;Check and compare pressure HPPT1 with HPPG1 0 Bar;;2;;;;; -101:05;MRL;Close MBV;;2;;;;00:30; -100:35;MRL;Safety is ensured;;1;;;;; -100:35;MCC;MiS to MRL;;1;;;;; -100:35;EGSE;Switch off N20 coupling;;1;;;;; -100:35;EGSE;Switch off HE coupling;;1;;;;; -100:35;MRL;Release Pneumatic lines;;1;;;;00:20; -100:15;EGSE;Confirm Fueling arm is off;;1;;;;; -100:15;EGSE;Check OxOutPT and HPLPT 0 bar;;1;;;;; -100:15;MRL;Couple Helium coupling;;1;;;;00:30; -99:45;MRL;Couple N2O coupling;;1;;;;00:30; -99:15;MRL;HOLD / RESTART;;1;;;;; -99:15;MRL;BEGIN Arming Rocket SEQUENCE Part 1;Arming 1;1;;;;; -99:15;MRL;Connect Ignition Umbilical;;1;;;;00:30; -98:45;MRL;Turn on GoPro Camera at end of Launch Rail;;1;;;;00:20; -98:25;MRL;Insert EPS Bridges;;1;;;;03:00; -95:25;MRL;Confirm Bridge Hatch is Secured;;1;;;;00:20; -95:05;EGSE@MRL;return to MCC;;1;;;;; -95:05;OPS;Elevate MRL to 90 degrees;;1;;;;05:00; -90:05;EGSE;Powercycle EPS to to start flight mode on Telemega;;1;;;;00:30; -89:35;EGSE;Calibrate loadcell (Set to 0);;1;;;;01:00; -88:35;MCC;BEGIN Pressure Test Flight Segment (PHASE YELLOW) ;Pressure Test Rocket;2;;;;; -88:35;MRL;Put on safety equipment;;2;;;;00:30; -88:05;MRL;Open HE Bottle 1;;2;;;;01:00; -87:05;MRL;Step back;;2;;;;; -87:05;EGSE;Open & Close stepwise MPV1/MPV2 to 50 Bar @ OxInPT1 & OxInPT2;;2;;;;; -87:05;MRL;Check & compare OxInPT1 with OxInPG1 based on Bottle temperature (max 50 bar);;2;;;;; -87:05;MRL;Check & compare pressure OxInPT2 with OxInPG2 based on Bottle temperature (max 50 bar);;2;;;;; -87:05;MRL;Check Temperature of N2O Bottle 1 @OxT1 & OxWT1 (max 22C);;2;;;;; -87:05;MRL;Check Temperature of N2O Bottle 2 @OxT2 & OxWT2 (max 22C);;2;;;;01:30; -85:35;MRL;Open He Bottle 2;;2;;;;; -85:35;MRL;Check & compare pressure HPPT2 with HPPG2 (max 315 bar);;2;;;;01:00; -84:35;ALL;CAUTION!;;2;;;;; -84:35;MRL;Open N2O Bottle 1;;2;;;;; -84:35;MRL/EGSE;Check & compare pressure OxInPT 1 with OxInPG 1 (max 50 bar);;2;;;;02:00; -82:35;MRL;Open N2O Bottle 2;;2;;;;; -82:35;MRL/EGSE;Check & compare pressure OxInPT 2 with OxInPG 2 (max 50 bar);;2;;;;02:00; -80:35;MRL;Insert Ignition Bridges B1 and B2 into EGSE;;2;;;;02:00; -78:35;MRL;Confirm Soundsignal from Ignition Umbilical;;2;;;;; -78:35;MRL;Close ComTerm;;2;;;;; -78:35;ALL;Clear Launchpad and inform OPS;;2;;;;10:00; -68:35;KLP;Start Camera Karsten Lappöhn;;2;;;;; -68:35;MCC;HOLD / RESTART;HOLD / RESTART;2;;;;; -68:35;MCC;Begin of Ox FUELING Sequence (PHASE RED);Ox Fueling (PHASE RED);3;;;;; -68:35;TMTC;Confirm GPS-lock;;3;;;;; -68:35;OBDH;Acknowledge start of Fueling;;3;;;;01:00;CHANGE to 3 steps -67:35;EGSE;Open & Close HPV1 to 50 Bar @ ROxTPT (stop at 30 bar and wait 30 seconds to check for leakage);;3;;;;; -67:35;EGSE;Open & Close HPV1 to more than 50 Bar @ RHPPT and check ROxTPT 50 Bar;;3;;;;; -67:35;EGSE;Check if HPV1 is closed;;3;;;;; -67:35;OBDH;Open RDV shortly, to check tightness @ RHPPT & ROxTPT (If leakages occur Abort);;3;;;;; -67:35;EGSE;Open MPV1/MPV2;;3;;;;; -67:35;EGSE;Open & Close stepwise MPV3 to 50 Bar @ OxOutPT;;3;;;;; -67:35;EGSE;Close MPV1/MPV2;;3;;;;; -67:35;EGSE;Check & compare OxOutPT with OxInPT1;;3;;;;; -67:35;EGSE;Check if RHPPT & ROxTPT more than OxInPT1, If less Open & Close HPV1;;3;;;;; -67:35;EGSE;Zero OxTank Mass;;3;;;;; -67:35;MCC;Write down Time;;3;;;;; -67:35;EGSE;Open OxV1 ;;3;;;;04:00; -63:35;OBDH;Open stepwise RDV until N2O bottle empty or 25kg OxTankMass, keep temperatures RDVT and RDVET above 10°C and Check delta ROxTPT and OxInPT1;;3;;;;30:00; -33:35;EGSE;Close OxV1;;3;;;;00:10; -33:25;EGSE;Check if Pressure rises in OxPT1, if Pressure rises relief via OxV1 or wait for Pressure relief valve;;3;;;;01:00; -32:25;EGSE;Check & compare OxOutPT with OxInPT2;;3;;;;; -32:25;EGSE;Check & compare RHPPT & ROxTPT 50 Bar and more than OxInPT2, If less Open & Close HPV1;;3;;;;; -32:25;EGSE;Open OxV2 ;;3;;;;; -32:25;OBDH;Open stepwise RDV to 25kg OxTankMass, keep temperatures RDVT and RDVET above 10°C and Check delta OxTPT and OxInPT1;;3;;;;20:00; -12:25;EGSE;Close OxV2 ;;3;;;;00:10; -12:15;EGSE;Check if Pressure rises in OxPT2, if Pressure rises relief via OxV2 or wait for Pressure relief valve;;3;;;;01:00; -11:15;EGSE;Open stepwise OxDV until OxOutPT 0 Bar;;3;;;;; -11:15;OBDH;Check ROxCV for tightness @ ROxTPT;;3;;;;; -11:15;EGSE;Close OxDV;;3;;;;01:00; -10:15;EGSE;Write down OxTankMass;;3;;;;; -10:15;MCC;Provied OxTankMass and Temperature Readings to Windwaiting Station;;3;;;;00:30; -09:45;EGSE;Confirm OxV1 & OxV2 closed;;3;;;;; -09:45;EGSE;Check OxOutPT 0 Bar;;3;;;;; -09:45;EGSE;Decouple N2O coupling;;3;;;;00:20; -09:25;MCC;Confirm End of Oxidator Fueling to OPS;;3;;;;00:15; -09:10;OBDH/TMTC;Check RF451-Link;;3;;;;00:20; -08:50;TMTC;Check GPS-lock;;3;;;;00:20; -08:30;TMTC;Check Telemega-Link;;3;;;;00:20; -08:10;MCC;Scheduled HOLD;;3;;;;; -08:10;ALL;Align MRL to Launch Trajectory;;3;;;;; -08:10;MCC;Confirm MRL adjustment is final;;3;;;;; -08:10;ALL;Talk through Launch Sequence;;3;;;;; -08:10;AVC;Start Video Recording in BlockHouse;;3;;;;; -08:10;MCC;Turn audio volume down;;3;;;;; -08:10;MCC;CONTINUE AFTER HOLD;;;;;;; -08:10;MCC;BEGIN Switching to Internal Power Sequence;Switch to Internal Power;3;;;;; -08:10;EGSE;Switch to internal Power;;3;;;;00:20; -07:50;OBDH;Confirm EPS Voltages are within limits;;3;;;;00:10; -07:45;OBDH;Confirm RF451 Transmitting;;3;;;;00:05; -07:20;OBDH/TMTC;Confirm RF451-Link;;3;;;;00:20; -07:40;TMTC;Confirm GPS-lock;;3;;;;00:20; -07:00;TMTC;Confirm Telemega-Link;;3;;;;00:20; -06:40;OBDH;Switch to PREAMRED;;3;;;;00:10; -06:30;PYL;Confirm Payload is running;;3;;;;00:20; -06:10;AVC;Check if videorecording @ MCC is running;;3;;;;00:05; -06:05;MCC;High Pressure Fuling;HP Fueling;3;;;;; -06:05;EGSE;Open and close HPV1 stepwise until RHPPT 300 Bar or pressure equal to HE Bottle 1;;3;;;;; -06:05;EGSE;Open and close HPV2 stepwise until RHPPT 300 Bar ;;3;;;;; -06:05;EGSE;Open and close HPDV stepwise until HPLPT 0 Bar ;;3;;;;; -06:05;EGSE;Check HPDV closed;;3;;;;; -06:05;OBDH/EGSE;Check for leakage HPLPT 0 Bar & RHPPT 300 Bar ;;3;;;;02:00; -04:05;OBDH;Acknowledge end of Fueling;;3;;;;00:10; -03:55;MCC;Confirm End of Fueling to OPS;;3;;;;00:20; -03:35;MCC;BEGIN of Moving Fueling Arm Away Sequence;Move Fueling Arm away;3;;;;00:10; -03:25;EGSE;Confirm HPV1 & HPV2 closed;;3;;;;00:10; -03:15;EGSE;Check HPLPT 0 Bar ;;3;;;;00:10; -03:05;EGSE;Decouple Helium coupling;;3;;;;00:20; -02:45;EGSE;Confirm Helium coupling is disconnected;;3;;;;00:10; -02:35;EGSE;Move fueling arm away from rocket;;3;;;;00:40; -01:55;MCC;Confirm Fueling Arm away to OPS;;3;;;;00:15; -01:40;MCC;Prepare for Launch;;3;;;;00:10; -01:30;OBDH;Confirm ready for launch;;3;;;;00:10; -01:20;EGSE;Confirm ready for launch;;3;;;;00:10; -01:10;MCC;Set Go/No-Go System to Go;;3;;;;00:10; -01:00;MCC;Wait for Authorization for Launch;;3;;;;00:00; -01:00;MCC;BEGIN of Ignition Sequence;Ignition Sequence;4;;;;00:10; -00:50;OBDH;ARM;;4;;;;00:05; -00:45;OBDH;Confirm all status indicators green;;4;;;;00:05; -00:40;OBDH;Ethernet Disconnect;;4;;;;00:30; -00:10;EGSE;Turn on Ignition Secure;;4;;;;00:07; -00:03;EGSE;T-3: Ignition;;4;;;;00:03; -00:00;OBDH;T+0: Verify RMOxOV Open (Launched);;4;;;;00:00; -00:00;EGSE;T+1: Turn OFF Ignition;;4;;;;; -00:00;EGSE;T+5: Turn OFF Ignition Secure;;4;;;;; -00:00;OBDH;T+20: Verify RMOxOV Closed and RMOxSV Open (Cruise);;4;;;;; -00:00;OBDH;T+50: Verify RNCEV Open (Drogue);;4;;;;; -00:00;OBDH;T+310: Verify Main Chute Deployed and RDV Open (Main);;4;;;;; -00:00;OBDH;T+600: Verify (Landed);;4;;;;; -00:00;MCC;START OF PASSIVATION (PHASE YELLOW) (Write down Time);Passivation;2;;;;; -00:00;MCC;Turn audio volume up;;2;;;;; -00:00;TMTC;Check ROxTPT & RHPPT 1 Bar, if more: Open & Close stepwise RDV;;2;;;;; -00:00;MRL;Go to Testrig, close N2O Bottle 1 & N2O Bottle 2 and return to BlockHouse;;2;;;;; -00:00;EGSE;Open OxDV;;2;;;;; -00:00;EGSE;Open OxV1;;2;;;;; -00:00;EGSE;Check OxInPT1 & OxOutPT 0 Bar;;2;;;;; -00:00;EGSE;Close OxV1;;2;;;;; -00:00;EGSE;Open OxV2;;2;;;;; -00:00;EGSE;Check OxInPT2 & OxOutPT 0 Bar;;2;;;;; -00:00;EGSE;Close OxV2;;2;;;;; -00:00;EGSE;Close OxDV ;;2;;;;; -00:00;MRL;Go to MRL, confirm OxInPG1 & OxInPG2 0 Bar, else return to BlockHouse, then close HE Bottle;;2;;;;; -00:00;MRL;Write down remaining Pressure of HE Bottle;;2;;;;; -00:00;EGSE;Open HPDV;;2;;;;; -00:00;EGSE;Open HPV2;;2;;;;; -00:00;EGSE;Check pressure HPLPT & HPPT2 0 Bar;;2;;;;; -00:00;EGSE;Close HPV2;;2;;;;; -00:00;EGSE;Close HPDV;;2;;;;; -00:00;MRL;Go to Testrig, confirm HPPG2 0 Bar, else return to BlockHouse, then open ComTerm;;2;;;;; -00:00;MRL;Close N2 Bottle;;2;;;;; -00:00;MRL;Write down remaining Pressure of N2 Bottle;;2;;;;; -00:00;MRL;Step back;;2;;;;; -00:00;MRL;Check EPV manometer less than 6 bar;;2;;;;; -00:00;MRL;Open MBV;;2;;;;; -00:00;EGSE;Check and compare pressure HPPT1 with HPPG1;;2;;;;; -00:00;MRL;Close MBV;;2;;;;; -00:00;MRL;Take out B1 & B2 Bridges;;2;;;;; -00:00;MRL;Safety is ensured;;2;;;;; -00:00;MCC;Turn off area warning light and open barrier;;1;;;;; -00:00;MCC;END OF PASSIVATION (PHASE GREEN) (Write down Time);;1;;;;; -00:00;MCC;START DATA COLLECTION (Write down Time);Collection;1;;;;; -00:00;AVC;Turn off GoPro & Camcorder & Stop BlockHouse Video recording;;1;;;;; -00:00;EGSE;Copy PID.vi.tdms & save to new name;;1;;;;; -00:00;EGSE;Wait for buffer storage process to be finished;;1;;;;; -00:00;EGSE;save data files from cRIO to PC;;1;;;;; -00:00;AVC;End audio recording;;1;;;;; -00:00;MCC;END OF PROCEDURE (Write Down Time);;1;;;;; -00:00;AVC;Save video & audio data on external HDD;;1;;;;; -00:00;MCC;Stop RT_CD.vi and save logfile to external HDD;;1;;;;; -00:00;MCC;PROCEDURE FINISHED;End;1;;;;; +147:20;EGSE;BEGIN of Power on EGSE Sequence;Power on EGSE;1;;;;; +147:20;EGSE;Check CLD connection;;1;;;;; +147:20;EGSE;Switch on CLD via Battery & check voltage (24 Volt);;1;;;;; +147:20;EGSE;Switch on the primary and secondary supply switches on the Control Panel;;1;;;;01:00; +146:20;EGSE@MRL;Switch on Sup_24V_20A & check voltage (ca. 27,2 Volt);;1;;;;; +146:20;EGSE@MRL;Switch on Sup_24V_10A & check voltage (ca. 27,2 Volt);;1;;;;; +146:20;EGSE@MRL;Switch on Sup_12V_10A & check voltage (ca. 13,8 Volt);;1;;;;; +146:20;EGSE@MRL;Switch on Bat_24V_20A & check voltage (ca. 27,9 Volt);;1;;;;; +146:20;EGSE@MRL;Switch on Bat_24V_10A & check voltage (ca. 27,9 Volt);;1;;;;; +146:20;EGSE@MRL;Switch on Bat_12V_10A & check voltage (ca. 13,8 Volt);;1;;;;; +146:20;EGSE@MRL;Switch on Sup_24V_40A;;1;;;;; +146:20;EGSE@MRL;Switch on Sup_5V_10A;;1;;;;03:00; +143:20;EGSE;Connect to cRIO;;1;;;;; +143:20;EGSE;Start FPGA_VI;;1;;;;; +143:20;EGSE;Start RT_VI;;1;;;;; +143:20;EGSE;Confirm PID-VI is running;;1;;;;; +143:20;EGSE;Rename PID-Logfile;;1;;;;02:00; +141:20;MRL;Confirm working Personel is grounded;;1;;;;; +141:20;EGSL@MRL;Confirm all 8 Groundingbridges are inserted;;1;;;;; +141:20;MRL;Connect Data Umbilical;Connect Data Umbilical;1;;;;00:30; +140:50;EGSE;Turn on EPS_BAT;;1;;;;; +140:50;EGSE;Turn on EPS_EXT;;1;;;;; +140:50;EGSE@MRL;Remove 7 Grounding Bridges and leave EPS_BAT inserted;;1;;;;; +140:50;EGSE@MRL;Insert EPS_EXT Fuse in Power Supply Control Panel;;1;;;;; +140:50;EGSE@MRL;Confirm green LED at EPS_EXT Fuse is on;;1;;;;; +140:50;EGSE@MRL;Insert Main_Bus Fuse in Power Supply Control Panel;;1;;;;; +140:50;EGSE@MRL;Confirm LED at Main_Bus Fuse is OFF. Else Pull fuse and insert all Grounding Bridges;;1;;;;; +140:50;EGSE@MRL;Set remaining Fuses (except Payload Fuse) and check for green LED;;1;;;;; +140:50;EGSE;Turn OFF EPS_BAT;;1;;;;; +140:50;EGSE@MRL;Confirm Main bus LED is on.;;1;;;;; +140:50;EGSE;Start EPS via EPS_ext;;1;;;;; +140:50;OBDH;Clear SD-Card-using FileZilla FTP;;1;;;;01:00; +139:50;OBDH;Connect to sbRIO;;1;;;;; +139:50;OBDH;Start RT_Main;;1;;;;; +139:50;MRL;Confirm 3 beeps at OBC1;;1;;;;; +139:50;OBDH;Open RT_Sub_HMI;;1;;;;; +139:50;OBDH;Confirm Main Chute button is disabled;;1;;;;; +139:50;EGSE@MRL;Insert Payload Fuse;;1;;;;; +139:50;EGSE@MRL;Confirm green LED at Payload Fuse is on;;1;;;;; +139:50;MRL;Confirm working Personel is grounded;;1;;;;01:00; +138:50;MRL;Remove Pneumatic Line from Fueling arm;;1;;;;; +138:50;MRL;Move Fueling arm to rocket;;1;;;;; +138:50;MRL;Couple Helium coupling;;1;;;;; +138:50;MRL;Couple N2O coupling;;1;;;;; +138:50;MRL;Reattach Pneumatic Line to Fueling arm;;1;;;;03:00; +135:50;MRL;Confirm that Ignition Umbilical is disconnected;;1;;;;; +135:50;EGSE;BEGIN EGSE Valve and actuator check Sequence;Valve check;1;;;;; +135:50;MCC;Check if video recording is enabled @ MCC;;1;;;;00:10; +135:40;OBDH;Check EPS hardware Voltages;;1;;;;00:10; +135:30;EGSE;Start PID data recording;;1;;;;00:10; +135:20;MRL;Close HPNV;;1;;;;00:10; +135:10;EGSE/MRL;Switch OxDV to closed & check if magnetic valve LED is on;;1;;;;00:10; +135:00;EGSE/MRL;Switch HPDV to closed & check if magnetic valve LED is on;;1;;;;00:10; +134:50;EGSE/MRL;Check warning lamp on HPSM;;1;;;;00:10; +134:40;MRL;Remove loose equipment;;1;;;;03:00; +131:40;EGSE;Activate Heizi;;1;;;;00:10; +131:30;EGSE;Activate N2O_Heater 1;;1;;;;00:10; +131:20;EGSE;Activate N2O_Heater 2;;1;;;;00:10; +131:10;EGSE;Activate HE_Heater;;1;;;;00:10; +131:00;OBDH;Verify Heizi @ RDVT & RDVET;;1;;;;00:10; +130:50;EGSE/MRL;Verify Bottle Temperatures @ OxT1, OxT2, HPT2;;1;;;;00:10; +130:40;EGSE/MRL;Verify Water Temperatures @ Ox@T1, OxWT2, HPWT2;;1;;;;00:10; +130:30;EGSE;Deactivate Heizi;;1;;;;00:10; +130:20;EGSE;Check OxV1 (CLD & RT_VI);;1;;;;00:10; +130:10;EGSE;Check OxV2 (CLD & RT_VI);;1;;;;00:10; +130:00;EGSE;Check MPV3 (CLD & RT_VI);;1;;;;00:10; +129:50;EGSE;Check HPV1 (CLD & RT_VI);;1;;;;00:10; +129:40;EGSE;Check HPV2 (CLD & RT_VI);;1;;;;00:10; +129:30;EGSE;Check MPV1/2 (CLD & RT_VI);;1;;;;00:10; +129:20;EGSE;Check RDV (CLD & RT_VI);;1;;;;00:10; +129:10;EGSE;Check RMOxOV (CLD & RT_VI);;1;;;;00:10; +129:00;EGSE;Check RMOxSV (CLD & RT_VI);;1;;;;00:10; +128:50;OBDH;Activate Heizi;;1;;;;00:10; +128:40;OBDH;Verify Heizi @ RDVT & RDVET;;1;;;;01:00; +127:40;OBDH;Check RDV;;1;;;;00:10; +127:30;OBDH;Check RNCEV;;1;;;;00:10; +127:20;OBDH;Check RMOxOV;;1;;;;00:10; +127:10;OBDH;Check RMOxSV;;1;;;;00:10; +127:00;OBDH;Confirm RNCEV is disabled;;1;;;;00:10; +125:00;MRL;Check MBV closed;;1;;;;; +125:00;EGSE;Check if all valve switches are in OFF position (Except OxDV & HPDV);;1;;;;10:00; +115:00;MRL/EGSE;Check loadcell by applying force to it;;1;;;;00:20; +114:40;OBDH;Check RHPPT shows atmosphere;;1;;;;; +114:40;OBDH;Check ROxTPT shows atmosphere;;1;;;;; +114:40;OBDH;Check RIHPT shows atmosphere;;1;;;;; +114:40;OBDH;Check RCCPT shows atmosphere;;1;;;;; +114:40;OBDH;Check RBaro1 shows atmosphere;;1;;;;; +114:40;OBDH;Check RBaro2 shows atmosphere;;1;;;;; +114:40;EGSE;Check HPPT1 shows 0 bar;;1;;;;00:20; +114:20;EGSE;Check HPPT2 shows 0 bar;;1;;;;; +114:20;EGSE;Check HPLPT shows 0 bar;;1;;;;; +114:20;EGSE;Check OxInPT1 shows 0 bar;;1;;;;; +114:20;EGSE;Check OxInPT2 shows 0 bar;;1;;;;; +114:20;EGSE;Check OxOutPT shows 0 bar;;1;;;;00:20; +114:00;EGSE/MRL;Switch on N2O coupling & check if magnetic valve LED is on;;1;;;;; +114:00;EGSE/MRL;Switch on HE coupling & check if magnetic valve LED is on;;1;;;;; +114:00;EGSE/MRL;Switch on swivle arm & check if magnetic valve LED is on;;1;;;;; +114:00;EGSE;Switch off swivel arm & HE coupling & N2O coupling;;1;;;;01:00; +113:00;MRL;Confirm that Ignition Umbilical is disconnected;;1;;;;; +113:00;MRL;Connect Ignition test Receptical;;1;;;;; +113:00;EGSE@MRL;Plug in Bridges B1 and B2;;1;;;;; +113:00;MRL;Confirm Soundsignal from Ignition Umbilical;;1;;;;; +113:00;EGSE;Turn on Ignition Secure;;1;;;;; +113:00;EGSE/OBDH;Turn on Ignition Switch for 2 Second & Confirm ignition signal received at sbRio;;1;;;;; +113:00;EGSE;Turn off Ignition Secure;;1;;;;; +113:00;EGSE@MRL;Remove Bridges B1 and B2;;1;;;;; +113:00;MRL;Remove Ignition test Receptical;;1;;;;03:00; +110:00;MCC;Ground Segment Pressure Test (PHASE YELLOW) ;Ground Pressure Test;1;;;;; +110:00;MRL;Confirm that all hatches are closed;;1;;;;01:00; +109:00;MRL;Check HE bottle 1 connector is attached;;1;;;;; +109:00;MRL;Check HE bottle 2 connector is attached;;1;;;;; +109:00;MRL;Check N2O bottle 1 connector is attached;;1;;;;; +109:00;MRL;Check N2O bottle 2 connector is attached;;1;;;;; +109:00;MRL;Check hose between HPSM & N2OSM is connected on both ends;;1;;;;; +109:00;MRL;Check hose between HPSM & Flight Segment is connected on both ends;;1;;;;; +109:00;MRL;Check hose between N2OSM & Flight Segment is connected on both ends;;1;;;;; +109:00;MRL;Check Pneumatik hose is connected on both ends;;1;;;;02:00; +107:00;MRL;Put on safety equipment;;2;;;;; +107:00;MRL;Move into Position to open HE Bottle 1;;2;;;;; +107:00;MRL;Check if HPV1 is closed;;2;;;;; +107:00;MRL;Check if MPV1/2 is closed;;2;;;;; +107:00;MRL;Open HE Bottle 1;;2;;;;01:00; +106:00;MRL;Check & compare pressure HPPT1 with HPPG1 (max 300 bar);;2;;;;; +106:00;MRL;Check Gastech Silver HPPR1 (max 300 to 50 bar);;2;;;;; +106:00;MRL;Check Harris PPR (50 to 8 bar);;2;;;;; +106:00;MRL;Check pneumatic PPG (8 bar);;2;;;;; +106:00;MRL;Step back;;2;;;;01:00; +105:00;EGSE;Confirm HPPT1 is at 300 Bar;;2;;;;; +105:00;EGSE;Confirm HPLPT less than 10 Bar;;2;;;;; +105:00;EGSE/MRL;Open & Close HPV1 SHORTLY & Check HPPT1;;2;;;;; +105:00;EGSE/MRL;Open & Close HPV2 SHORTLY & Check HPPT2 0 bar;;2;;;;; +105:00;EGSE/MRL;Open & Close HPDV SHORTLY & Check HPLPT 0 bar;;2;;;;; +105:00;EGSE/MRL;Open & Close OxV1 SHORTLY;;2;;;;; +105:00;EGSE/MRL;Open & Close OxV2 SHORTLY;;2;;;;; +105:00;EGSE/MRL;Open & Close OxDV SHORTLY;;2;;;;; +105:00;EGSE/MRL;Open & Close MPV3 SHORTLY;;2;;;;; +105:00;EGSE;Check HPLPT & OxOutPT 0 Bar;;2;;;;01:30; +103:30;EGSE;Decouple N2O coupling;;2;;;;; +103:30;EGSE;Decouple Helium coupling;;2;;;;00:20; +103:10;EGSE;Move arm away from rocket;;2;;;;; +103:10;EGSE;Move arm to rocket;;2;;;;01:00; +102:10;MRL;Close HE Bottle 1 and check HPSM for leakage (If leakage occurs Abort);;2;;;;01:00; +101:10;MRL;Open HPNV 1/8 Rev;;2;;;;; +101:10;MRL;Open MBV;;2;;;;; +101:10;EGSE/MRL;Check and compare pressure HPPT1 with HPPG1 0 Bar;;2;;;;; +101:10;MRL;Close MBV;;2;;;;00:30; +100:40;MRL;Safety is ensured;;2;;;;; +100:40;MCC;MiS to MRL;;1;;;;; +100:40;EGSE;Switch off N20 coupling;;1;;;;; +100:40;EGSE;Switch off HE coupling;;1;;;;; +100:40;MRL;Release Pneumatic lines;;1;;;;00:20; +100:20;EGSE;Confirm Fueling arm is off;;1;;;;; +100:20;EGSE;Check OxOutPT and HPLPT 0 bar;;1;;;;; +100:20;MRL;Couple Helium coupling;;1;;;;00:30; +99:50;MRL;Couple N2O coupling;;1;;;;00:30; +99:20;MRL;HOLD / RESTART;;1;;;;; +99:20;MRL;BEGIN Arming Rocket SEQUENCE Part 1;Arming 1;1;;;;; +99:20;MRL;Connect Ignition Umbilical;;1;;;;00:30; +98:50;MRL;Turn on GoPro Camera at end of Launch Rail;;1;;;;00:20; +98:30;MRL;Insert EPS Bridges;;1;;;;03:00; +95:30;MRL;Confirm Bridge Hatch is Secured;;1;;;;00:20; +95:10;EGSE@MRL;return to MCC;;1;;;;; +95:10;OPS;Elevate MRL to 90 degrees;;1;;;;05:00; +90:10;EGSE;Powercycle EPS to to start flight mode on Telemega;;1;;;;00:30; +89:40;EGSE;Calibrate loadcell (Set to 0);;1;;;;01:00; +88:40;MCC;BEGIN Pressure Test Flight Segment (PHASE YELLOW) ;Pressure Test Rocket;2;;;;; +88:40;MRL;Put on safety equipment;;2;;;;00:30; +88:10;MRL;Open HE Bottle 1;;2;;;;01:00; +87:10;MRL;Step back;;2;;;;; +87:10;EGSE;Open & Close stepwise MPV1/MPV2 to 50 Bar @ OxInPT1 & OxInPT2;;2;;;;; +87:10;MRL;Check & compare OxInPT1 with OxInPG1 based on Bottle temperature (max 50 bar);;2;;;;; +87:10;MRL;Check & compare pressure OxInPT2 with OxInPG2 based on Bottle temperature (max 50 bar);;2;;;;; +87:10;MRL;Check Temperature of N2O Bottle 1 @OxT1 & OxWT1 (max 22C);;2;;;;; +87:10;MRL;Check Temperature of N2O Bottle 2 @OxT2 & OxWT2 (max 22C);;2;;;;01:30; +85:40;MRL;Open He Bottle 2;;2;;;;; +85:40;MRL;Check & compare pressure HPPT2 with HPPG2 (max 315 bar);;2;;;;01:00; +84:40;ALL;CAUTION!;;2;;;;; +84:40;MRL;Open N2O Bottle 1;;2;;;;; +84:40;MRL/EGSE;Check & compare pressure OxInPT 1 with OxInPG 1 (max 50 bar);;2;;;;02:00; +82:40;MRL;Open N2O Bottle 2;;2;;;;; +82:40;MRL/EGSE;Check & compare pressure OxInPT 2 with OxInPG 2 (max 50 bar);;2;;;;02:00; +80:40;MRL;Insert Ignition Bridges B1 and B2 into EGSE;;2;;;;02:00; +78:40;MRL;Confirm Soundsignal from Ignition Umbilical;;2;;;;; +78:40;MRL;Close ComTerm;;2;;;;; +78:40;ALL;Clear Launchpad and inform OPS;;2;;;;10:00; +68:40;KLP;Start Camera Karsten Lappöhn;;2;;;;; +68:40;MCC;HOLD / RESTART;HOLD / RESTART;2;;;;; +68:40;MCC;Begin of Ox FUELING Sequence (PHASE RED);Ox Fueling (PHASE RED);3;;;;; +126:50;OBDH/TMTC;Check RF451-Link;;1;;;;00:20; +126:30;TMTC;Confirm GPS-lock;;1;;;;00:20; +126:10;TMTC;Confirm Telemega-Link;;1;;;;00:20; +125:50;OBDH;Test Connection to STX3;;1;;;;00:20; +125:30;OBDH;Confirm that STX3 Package received by email;;1;;;;00:30; +68:40;OBDH;Acknowledge start of Fueling;;3;;;;01:00;CHANGE to 3 steps +67:40;EGSE;Open & Close HPV1 to 50 Bar @ ROxTPT (stop at 30 bar and wait 30 seconds to check for leakage);;3;;;;; +67:40;EGSE;Open & Close HPV1 to more than 50 Bar @ RHPPT and check ROxTPT 50 Bar;;3;;;;; +67:40;EGSE;Check if HPV1 is closed;;3;;;;; +67:40;OBDH;Open RDV shortly, to check tightness @ RHPPT & ROxTPT (If leakages occur Abort);;3;;;;; +67:40;EGSE;Open MPV1/MPV2;;3;;;;; +67:40;EGSE;Open & Close stepwise MPV3 to 50 Bar @ OxOutPT;;3;;;;; +67:40;EGSE;Close MPV1/MPV2;;3;;;;; +67:40;EGSE;Check & compare OxOutPT with OxInPT1;;3;;;;; +67:40;EGSE;Check if RHPPT & ROxTPT more than OxInPT1, If less Open & Close HPV1;;3;;;;; +67:40;EGSE;Zero OxTank Mass;;3;;;;; +67:40;MCC;Write down Time;;3;;;;; +67:40;EGSE;Open OxV1 ;;3;;;;04:00; +63:40;OBDH;Open stepwise RDV until N2O bottle empty or 25kg OxTankMass, keep temperatures RDVT and RDVET above 10°C and Check delta ROxTPT and OxInPT1;;3;;;;30:00:00; +33:40;EGSE;Close OxV1;;3;;;;00:10; +33:30;EGSE;Check if Pressure rises in OxPT1, if Pressure rises relief via OxV1 or wait for Pressure relief valve;;3;;;;01:00; +32:30;EGSE;Check & compare OxOutPT with OxInPT2;;3;;;;; +32:30;EGSE;Check & compare RHPPT & ROxTPT 50 Bar and more than OxInPT2, If less Open & Close HPV1;;3;;;;; +32:30;EGSE;Open OxV2 ;;3;;;;; +32:30;OBDH;Open stepwise RDV to 25kg OxTankMass, keep temperatures RDVT and RDVET above 10°C and Check delta OxTPT and OxInPT1;;3;;;;20:00; +12:30;EGSE;Close OxV2 ;;3;;;;00:10; +12:20;EGSE;Check if Pressure rises in OxPT2, if Pressure rises relief via OxV2 or wait for Pressure relief valve;;3;;;;01:00; +11:20;EGSE;Open stepwise OxDV until OxOutPT 0 Bar;;3;;;;; +11:20;OBDH;Check ROxCV for tightness @ ROxTPT;;3;;;;; +11:20;EGSE;Close OxDV;;3;;;;01:00; +10:20;EGSE;Write down OxTankMass;;3;;;;; +10:20;MCC;Provied OxTankMass and Temperature Readings to Windwaiting Station;;3;;;;00:30; +9:50;EGSE;Confirm OxV1 & OxV2 closed;;3;;;;; +9:50;EGSE;Check OxOutPT 0 Bar;;3;;;;; +9:50;EGSE;Decouple N2O coupling;;3;;;;00:20; +9:30;MCC;Confirm End of Oxidator Fueling to OPS;;3;;;;00:15; +9:15;OBDH/TMTC;Check RF451-Link;;3;;;;00:20; +8:55;TMTC;Check GPS-lock;;3;;;;00:20; +8:35;TMTC;Check Telemega-Link;;3;;;;00:20; +8:15;MCC;Scheduled HOLD;;3;;;;; +8:15;ALL;Align MRL to Launch Trajectory;;3;;;;; +8:15;MCC;Confirm MRL adjustment is final;;3;;;;; +8:15;ALL;Talk through Launch Sequence;;3;;;;; +8:15;AVC;Start Video Recording in BlockHouse;;3;;;;; +8:15;MCC;Turn audio volume down;;3;;;;; +8:15;MCC;CONTINUE AFTER HOLD;;;;;;; +8:15;MCC;BEGIN Switching to Internal Power Sequence;Switch to Internal Power;3;;;;; +8:15;EGSE;Switch to internal Power;;3;;;;00:20; +7:55;OBDH;Confirm EPS Voltages are within limits;;3;;;;00:10; +7:45;OBDH;Confirm RF451 Transmitting;;3;;;;00:05; +7:40;OBDH/TMTC;Confirm RF451-Link;;3;;;;00:20; +7:20;TMTC;Confirm GPS-lock;;3;;;;00:20; +7:00;TMTC;Confirm Telemega-Link;;3;;;;00:20; +6:40;OBDH;Switch to PREAMRED;;3;;;;00:10; +6:30;PYL;Confirm Payload is running;;3;;;;00:20; +6:10;AVC;Check if videorecording @ MCC is running;;3;;;;00:05; +6:05;MCC;High Pressure Fuling;HP Fueling;3;;;;; +6:05;EGSE;Open and close HPV1 stepwise until RHPPT 300 Bar or pressure equal to HE Bottle 1;;3;;;;; +6:05;EGSE;Open and close HPV2 stepwise until RHPPT 300 Bar ;;3;;;;; +6:05;EGSE;Open and close HPDV stepwise until HPLPT 0 Bar ;;3;;;;; +6:05;EGSE;Check HPDV closed;;3;;;;; +6:05;OBDH/EGSE;Check for leakage HPLPT 0 Bar & RHPPT 300 Bar ;;3;;;;02:00; +4:05;OBDH;Acknowledge end of Fueling;;3;;;;00:10; +3:55;MCC;Confirm End of Fueling to OPS;;3;;;;00:20; +3:35;MCC;BEGIN of Moving Fueling Arm Away Sequence;Move Fueling Arm away;3;;;;00:10; +3:25;EGSE;Confirm HPV1 & HPV2 closed;;3;;;;00:10; +3:15;EGSE;Check HPLPT 0 Bar ;;3;;;;00:10; +3:05;EGSE;Decouple Helium coupling;;3;;;;00:20; +2:45;EGSE;Confirm Helium coupling is disconnected;;3;;;;00:10; +2:35;EGSE;Move fueling arm away from rocket;;3;;;;00:40; +1:55;MCC;Confirm Fueling Arm away to OPS;;3;;;;00:15; +1:40;MCC;Prepare for Launch;;3;;;;00:10; +1:30;OBDH;Confirm ready for launch;;3;;;;00:10; +1:20;EGSE;Confirm ready for launch;;3;;;;00:10; +1:10;MCC;Set Go/No-Go System to Go;;3;;;;00:10; +1:00;MCC;Wait for Authorization for Launch;;3;;;;00:00; +1:00;MCC;BEGIN of Ignition Sequence;Ignition Sequence;4;;;;00:10; +0:50;OBDH;ARM;;4;;;;00:05; +0:45;OBDH;Confirm all status indicators green;;4;;;;00:05; +0:40;OBDH;Ethernet Disconnect;;4;;;;00:30; +0:10;EGSE;Turn on Ignition Secure;;4;;;;00:07; +0:03;EGSE;T-3: Ignition;;4;;;;00:03; +0:00;OBDH;T+0: Verify RMOxOV Open (Launched);;4;;;;00:00; +0:00;EGSE;T+1: Turn OFF Ignition;;4;;;;; +0:00;EGSE;T+5: Turn OFF Ignition Secure;;4;;;;; +0:00;OBDH;T+20: Verify RMOxOV Closed and RMOxSV Open (Cruise);;4;;;;; +0:00;OBDH;T+50: Verify RNCEV Open (Drogue);;4;;;;; +0:00;OBDH;T+310: Verify Main Chute Deployed and RDV Open (Main);;4;;;;; +0:00;OBDH;T+600: Verify (Landed);;4;;;;; +0:00;MCC;START OF PASSIVATION (PHASE YELLOW) (Write down Time);Passivation;2;;;;; +0:00;MCC;Turn audio volume up;;2;;;;; +0:00;TMTC;Check ROxTPT & RHPPT 1 Bar, if more: Open & Close stepwise RDV;;2;;;;; +0:00;MRL;Go to Testrig, close N2O Bottle 1 & N2O Bottle 2 and return to BlockHouse;;2;;;;; +0:00;EGSE;Open OxDV;;2;;;;; +0:00;EGSE;Open OxV1;;2;;;;; +0:00;EGSE;Check OxInPT1 & OxOutPT 0 Bar;;2;;;;; +0:00;EGSE;Close OxV1;;2;;;;; +0:00;EGSE;Open OxV2;;2;;;;; +0:00;EGSE;Check OxInPT2 & OxOutPT 0 Bar;;2;;;;; +0:00;EGSE;Close OxV2;;2;;;;; +0:00;EGSE;Close OxDV ;;2;;;;; +0:00;MRL;Go to MRL, confirm OxInPG1 & OxInPG2 0 Bar, else return to BlockHouse, then close HE Bottle;;2;;;;; +0:00;MRL;Write down remaining Pressure of HE Bottle;;2;;;;; +0:00;EGSE;Open HPDV;;2;;;;; +0:00;EGSE;Open HPV2;;2;;;;; +0:00;EGSE;Check pressure HPLPT & HPPT2 0 Bar;;2;;;;; +0:00;EGSE;Close HPV2;;2;;;;; +0:00;EGSE;Close HPDV;;2;;;;; +0:00;MRL;Go to Testrig, confirm HPPG2 0 Bar, else return to BlockHouse, then open ComTerm;;2;;;;; +0:00;MRL;Close N2 Bottle;;2;;;;; +0:00;MRL;Write down remaining Pressure of N2 Bottle;;2;;;;; +0:00;MRL;Step back;;2;;;;; +0:00;MRL;Check EPV manometer less than 6 bar;;2;;;;; +0:00;MRL;Open MBV;;2;;;;; +0:00;EGSE;Check and compare pressure HPPT1 with HPPG1;;2;;;;; +0:00;MRL;Close MBV;;2;;;;; +0:00;MRL;Take out B1 & B2 Bridges;;2;;;;; +0:00;MRL;Safety is ensured;;2;;;;; +0:00;MCC;Turn off area warning light and open barrier;;1;;;;; +0:00;MCC;END OF PASSIVATION (PHASE GREEN) (Write down Time);;1;;;;; +0:00;MCC;START DATA COLLECTION (Write down Time);Collection;1;;;;; +0:00;AVC;Turn off GoPro & Camcorder & Stop BlockHouse Video recording;;1;;;;; +0:00;EGSE;Copy PID.vi.tdms & save to new name;;1;;;;; +0:00;EGSE;Wait for buffer storage process to be finished;;1;;;;; +0:00;EGSE;save data files from cRIO to PC;;1;;;;; +0:00;AVC;End audio recording;;1;;;;; +0:00;MCC;END OF PROCEDURE (Write Down Time);;1;;;;; +0:00;AVC;Save video & audio data on external HDD;;1;;;;; +0:00;MCC;Stop RT_CD.vi and save logfile to external HDD;;1;;;;; +0:00;MCC;PROCEDURE FINISHED;End;1;;;;;