added payload test before fueling and fixed minor issues in the other procedures

This commit is contained in:
Finn 2020-06-08 09:43:28 +02:00
parent b424c30c49
commit cd8acfe487
3 changed files with 9 additions and 6 deletions

View File

@ -1,10 +1,11 @@
vers.;v4.27;Abort Procedure;;3;mrl;mcc;rdh;time
0:00;MCC;BEGIN SEQUENCE: Defueling Rocket;Defueling;3;;;;
vers.;v4.28;Abort Procedure;;3;mrl;mcc;rdh;time
0:00;MCC;BEGIN SEQUENCE: Prepare Launch Abort;Prepare Launch Abort;3;;;;
0:00;MCC;Inform OPS of Launch Abort;;3;;;;
0:00;EGSE;Confirm all valve switches are in OFF position (Except OxDV & HPDV);;3;;;;
0:00;OBDH;Confirm all valve switches are in OFF position (Except RMOxSV);;3;;;;
0:00;OBDH;Activate Heizi;;3;;;;
0:00;MCC;Turn audio volume up;;3;;;;
0:00;MCC;BEGIN SEQUENCE: Defueling Rocket;Defueling;3;;;;
0:00;OBDH;Activate Heizi;;3;;;;
0:00;EGSE;Open & Close OxDV STEPWISE until OxOutPT 0 Bar;;3;;;;
0:00;EGSE;Open OxDV;;3;;;;
0:00;EGSE;Open MPV3;;3;;;;

1 vers. v4.27 v4.28 Abort Procedure 3 mrl mcc rdh time
2 0:00 MCC MCC BEGIN SEQUENCE: Defueling Rocket BEGIN SEQUENCE: Prepare Launch Abort Defueling Prepare Launch Abort 3
3 0:00 MCC MCC Inform OPS of Launch Abort 3
4 0:00 EGSE EGSE Confirm all valve switches are in OFF position (Except OxDV & HPDV) 3
5 0:00 OBDH OBDH Confirm all valve switches are in OFF position (Except RMOxSV) 3
0:00 OBDH Activate Heizi 3
6 0:00 MCC MCC Turn audio volume up 3
7 0:00 MCC BEGIN SEQUENCE: Defueling Rocket Defueling 3
8 0:00 OBDH Activate Heizi 3
9 0:00 EGSE EGSE Open & Close OxDV STEPWISE until OxOutPT 0 Bar 3
10 0:00 EGSE EGSE Open OxDV 3
11 0:00 EGSE EGSE Open MPV3 3

View File

@ -1,4 +1,4 @@
vers.;v4.27;Launch Procedure;;0;MRL;MCC;RdHill;Time per step
vers.;v4.28;Launch Procedure;;0;MRL;MCC;RdHill;Time per step
147:20;MCC;BEGIN SEQUENCE: Power on EGSE;Power on EGSE;1;;;;
147:20;WIND;Start wind weighting analysis;;1;;;;
147:20;EGSE;Check CLD connection;;1;;;;
@ -273,6 +273,8 @@ vers.;v4.27;Launch Procedure;;0;MRL;MCC;RdHill;Time per step
125:50;OBDH;Test Connection to STX3;;3;;;;00:20
125:30;OBDH;Confirm that STX3 Packages are received by email;;3;;;;00:30
125:30;AVC;Turn on main TMTC screen;;3;;;;00:30
125:30;PYL;Confirm CanSat is running;;3;;;;00:20
125:30;PYL;Confirm BlackBox2 is running;;3;;;;
125:30;MCC;Request Permission to begin fueling from OPS;;3;;;;03:00
68:40;OBDH;Acknowledge start of Fueling;;3;;;;01:00
67:40;EGSE;Open & Close HPV1 STEPWISE to 50 Bar @ ROxTPT (stop every 10 bar & check ROxTBT & ROxTTT (approx. ambiente temp);;3;;;;

Can't render this file because it contains an unexpected character in line 155 and column 11.

View File

@ -1,5 +1,5 @@
vers.;v4.27;Passivation out of sequence Procedure;;2;mrl;mcc;rdh;time
0:00;MCC;BEGIN SEQUENCE: Prepare Passivation Sequence;Prepare Passivation;2;;;;
vers.;v4.28;Passivation out of sequence Procedure;;2;mrl;mcc;rdh;time
0:00;MCC;BEGIN SEQUENCE: Prepare Passivation;Prepare Passivation;2;;;;
0:00;MCC/MRL;Recall and make sure BOTH N2O Bottles & He Bottle 2 are still closed! Else continue with Abort Procedure;;2;;;;
0:00;MCC;Inform OPS of Passivation out of sequence;;2;;;;
0:00;MRL;Step Back/Leave MRL;;2;;;;

1 vers. v4.27 v4.28 Passivation out of sequence Procedure 2 mrl mcc rdh time
2 0:00 MCC BEGIN SEQUENCE: Prepare Passivation Sequence BEGIN SEQUENCE: Prepare Passivation Prepare Passivation 2
3 0:00 MCC/MRL Recall and make sure BOTH N2O Bottles & He Bottle 2 are still closed! Else continue with Abort Procedure 2
4 0:00 MCC Inform OPS of Passivation out of sequence 2
5 0:00 MRL Step Back/Leave MRL 2