added gitattributes so that the windows double line feed doesn't caus diffs all the time

This commit is contained in:
Finn 2020-06-05 12:47:59 +02:00
parent b3f3815b07
commit f9fa64a479
4 changed files with 4 additions and 3 deletions

1
.gitattributes vendored Normal file
View File

@ -0,0 +1 @@
* text=auto

View File

@ -1,4 +1,4 @@
vers.;v4.22;Abort Procedure;;3;;;;; vers.;v4.23;Abort Procedure;;3;;;;;
0:00;MCC;BEGIN SEQUENCE: Defueling Rocket;Defueling;3;;;;; 0:00;MCC;BEGIN SEQUENCE: Defueling Rocket;Defueling;3;;;;;
0:00;MCC;Inform OPS of Launch Abort;;3;;;;; 0:00;MCC;Inform OPS of Launch Abort;;3;;;;;
0:00;EGSE;Confirm all valve switches are in OFF position (Except OxDV & HPDV);;3;;;;; 0:00;EGSE;Confirm all valve switches are in OFF position (Except OxDV & HPDV);;3;;;;;

1 vers. v4.22 v4.23 Abort Procedure 3
2 0:00 MCC BEGIN SEQUENCE: Defueling Rocket Defueling 3
3 0:00 MCC Inform OPS of Launch Abort 3
4 0:00 EGSE Confirm all valve switches are in OFF position (Except OxDV & HPDV) 3

View File

@ -1,4 +1,4 @@
vers.;v4.22;Launch Procedure;;0;MRL;MCC;RdHill;Time per step; vers.;v4.23;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
147:20;MCC;BEGIN SEQUENCE: Power on EGSE;Power on EGSE;1;;;;; 147:20;MCC;BEGIN SEQUENCE: Power on EGSE;Power on EGSE;1;;;;;
147:20;WIND;Start wind weighting analysis;;1;;;;; 147:20;WIND;Start wind weighting analysis;;1;;;;;
147:20;EGSE;Check CLD connection;;1;;;;; 147:20;EGSE;Check CLD connection;;1;;;;;

1 vers. v4.22 v4.23 Launch Procedure 0 MRL MCC RdHill Time per step
2 147:20 MCC BEGIN SEQUENCE: Power on EGSE Power on EGSE 1
3 147:20 WIND Start wind weighting analysis 1
4 147:20 EGSE Check CLD connection 1

View File

@ -1,4 +1,4 @@
vers.;v4.22;Passivation out of sequence Procedure;;2;;;;; vers.;v4.23;Passivation out of sequence Procedure;;2;;;;;
0:00;MCC;BEGIN SEQUENCE: Prepare Passivation Sequence;Prepare Passivation;2;;;;; 0:00;MCC;BEGIN SEQUENCE: Prepare Passivation Sequence;Prepare Passivation;2;;;;;
0:00;MCC/MRL;Recall and make sure BOTH N2O Bottles & He Bottle 2 are still closed! Else continue with Abort Procedure;;2;;;;; 0:00;MCC/MRL;Recall and make sure BOTH N2O Bottles & He Bottle 2 are still closed! Else continue with Abort Procedure;;2;;;;;
0:00;MCC;Inform OPS of Passivation out of sequence;;2;;;;; 0:00;MCC;Inform OPS of Passivation out of sequence;;2;;;;;

1 vers. v4.22 v4.23 Passivation out of sequence Procedure 2
2 0:00 MCC BEGIN SEQUENCE: Prepare Passivation Sequence Prepare Passivation 2
3 0:00 MCC/MRL Recall and make sure BOTH N2O Bottles & He Bottle 2 are still closed! Else continue with Abort Procedure 2
4 0:00 MCC Inform OPS of Passivation out of sequence 2