vers.;v4.32;Launch Procedure;;0;MRL;MCC;RdHill;Time per step 147:20;MCC;BEGIN SEQUENCE: Power on EGSE;Power on EGSE;1;;;; 147:20;WIND;Start wind weighting analysis;;1;;;; 147:20;EGSE;Check CLD connection;;1;;;; 147:20;EGSE;Switch ON CLD via Battery & check voltage (24 Volt);;1;;;; 147:20;EGSE;Switch ON the primary and secondary supply switches on the Control Panel;;1;;;;01:00 146:20;EGSE @MRL;Switch ON Sup_24V_20A & check voltage (ca. 27,2 Volt);;1;;;; 146:20;EGSE @MRL;Switch ON Sup_24V_10A & check voltage (ca. 27,2 Volt);;1;;;; 146:20;EGSE @MRL;Switch ON Sup_12V_10A & check voltage (ca. 13,8 Volt);;1;;;; 146:20;EGSE @MRL;Switch ON Bat_24V_20A & check voltage (ca. 27,9 Volt);;1;;;; 146:20;EGSE @MRL;Switch ON Bat_24V_10A & check voltage (ca. 27,9 Volt);;1;;;; 146:20;EGSE @MRL;Switch ON Bat_12V_10A & check voltage (ca. 13,8 Volt);;1;;;; 146:20;EGSE @MRL;Switch ON Sup_24V_40A;;1;;;; 146:20;EGSE @MRL;Switch ON Sup_5V_10A;;1;;;;03:00 143:20;EGSE;Connect to cRio;;1;;;; 143:20;EGSE;Start RT_VI;;1;;;; 130:40;EGSE;Confirm storage capacity of cRio is greater than 300MB;;1;;;;00:10 143:20;EGSE;Open PID-VI and confirm it is running;;1;;;; 143:20;EGSE;Rename PID-Logfile;;1;;;;02:00 141:20;MCC;BEGIN SEQUENCE: Connect Data Umbilical;Connect Data Umbilical;1;;;;00:30 141:20;MRL;Confirm working personel is grounded;;1;;;; 141:20;EGSE @MRL;Confirm ALL 8 bridges on the right side are inserted;;1;;;; 141:20;EGSE @MRL;Confirm ALL 8 bridges on the left side are removed;;1;;;; 141:20;EGSE @MRL;Connect Data Umbilical;;1;;;; 0:00;EGSE @MRL;Remove EXT_24V GROUND Bridge (1R);;1;;;; 0:00;EGSE @MRL;Remove MAIN_BUS GROUND Bridge (2R);;1;;;; 0:00;EGSE @MRL;Remove OBC2_BAT GROUND Bridge (4R);;1;;;; 0:00;EGSE @MRL;Remove PAYLOAD1 GROUND Bridge (5R);;1;;;; 0:00;EGSE @MRL;Remove RECOVERY_BAT GROUND Bridge (7R);;1;;;; 140:50;EGSE;Turn ON EPS_BAT;;1;;;; 140:50;EGSE;Turn ON EPS_EXT_24V;;1;;;; 0:00;EGSE @MRL;Insert EXT_24V Bridge (1L);;1;;;; 0:00;EGSE @MRL;Confirm EXT_24V LED is ON;;1;;;; 0:00;EGSE @MRL;Insert MAIN_BUS Bridge (2L);;1;;;; 0:00;EGSE @MRL;Confirm MAIN_BUS LED is OFF (if ON pull MAIN_BUS Bridge (2L) & Insert all grounding Bridges on the right side;;1;;;; 0:00;EGSE @MRL;Remove EPS RADIO SILENCE Bridge (3R);;1;;;; 0:00;EGSE;Turn OFF EPS_BAT;;1;;;; 0:00;EGSE @MRL;Confirm MAIN_BUS LED is ON;;1;;;; 0:00;EGSE @MRL;Confirm 1 beep at Telemega;;1;;;; 140:50;OBDH;Start OBC1;;1;;;;01:00 139:50;MRL;Confirm 3 beeps at OBC1;;1;;;; 140:50;OBDH;Clear SD-Card-using FileZilla FTP;;1;;;;01:00 139:50;OBDH;Connect to sbRio using remote Access utility;;1;;;; 139:50;OBDH;Open RT_Sub_HMI;;1;;;; 139:50;OBDH;Confirm Main Chute button is disabled;;1;;;; 135:40;OBDH;Check EPS hardware Voltages;;1;;;;00:10 0:00;EGSE;Check EGSE Currents;;1;;;;00:10 139:50;WIND;Report on weather situation;;1;;;; 139:50;MCC;BEGIN SEQUENCE: Connect Fueling arm @HPSM;Connect Fueling Arm;1;;;; 139:50;MRL;Confirm working personel is grounded;;1;;;;01:00 139:50;MRL;Confirm PPG 0 bar;;1;;;; 138:50;MRL;Remove Pneumatic Line from Fueling arm;;1;;;; 138:50;MRL;Move Fueling arm to rocket;;1;;;; 138:50;MRL;Couple Helium coupling;;1;;;; 138:50;MRL;Couple N2O coupling;;1;;;; 138:50;MRL;Reattach Pneumatic Line to Fueling arm @HPSM;;1;;;;03:00 135:50;MCC;BEGIN SEQUENCE: EGSE sensor and actuator test;EGSE sensor & actuator test;1;;;; 135:50;MCC;Confirm that video recording is enabled @ MCC;;1;;;;00:10 135:50;MRL;Confirm that Ignition Umbilical is disconnected;;1;;;; 135:30;EGSE;Start PID data recording;;1;;;;00:10 135:20;MRL;Close HPNV1;;1;;;;00:10 135:20;MRL;Close HPNV2;;1;;;;00:10 135:10;EGSE/ MRL;Switch OxDV to closed & check if magnetic valve LED is on;;1;;;;00:10 135:00;EGSE/ MRL;Switch HPDV to closed & check if magnetic valve LED is on;;1;;;;00:10 134:50;EGSE/ MRL;Check warning lamp on HPSM;;1;;;;00:10 134:40;MRL;Remove loose equipment;;1;;;;03:00 131:40;EGSE/ MRL;Turn ON & OFF Rocket Heater & confirm it's heating;;1;;;;00:10 131:30;EGSE/ MRL;Turn ON & OFF N2O_Heater 1 & confirm it's heating;;1;;;;00:10 131:20;EGSE/ MRL;Turn ON & OFF N2O_Heater 2 & confirm it's heating;;1;;;;00:10 131:10;EGSE/ MRL;Turn ON & OFF He_Heater & confirm it's heating;;1;;;;00:10 131:00;OBDH;Verify Rocket Heater @ RDVT & RDVET;;1;;;;00:10 130:50;EGSE/ MRL;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;;1;;;;00:10 130:40;EGSE/ MRL;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;1;;;;00:10 130:30;EGSE;Deactivate Rocket Heater;;1;;;;00:10 130:20;EGSE/ MRL;Check OxV1 (CLD & RT_VI);;1;;;;00:10 130:10;EGSE/ MRL;Check OxV2 (CLD & RT_VI);;1;;;;00:10 130:00;EGSE/ MRL;Check MPV3 (CLD & RT_VI);;1;;;;00:10 129:50;EGSE/ MRL;Check HPV1 (CLD & RT_VI);;1;;;;00:10 129:40;EGSE/ MRL;Check HPV2 (CLD & RT_VI);;1;;;;00:10 129:30;EGSE/ MRL;Check MPV1/2 (CLD & RT_VI);;1;;;;00:10 129:20;EGSE/ MRL;Check RDV (CLD & RT_VI);;1;;;;00:10 129:10;EGSE/ MRL;Check RMOxOV (CLD & RT_VI);;1;;;;00:10 129:00;EGSE/ MRL;Check RMOxSV (CLD & RT_VI);;1;;;;00:10 128:50;OBDH;Activate Rocket Heater;;1;;;;00:10 128:40;OBDH;Verify Rocket Heater @ RDVT & RDVET;;1;;;;01:00 127:40;OBDH/ MRL;Check RDV;;1;;;;00:10 127:30;OBDH/ MRL;Check RNCEV;;1;;;;00:10 127:20;OBDH/ MRL;Check RMOxOV;;1;;;;00:10 127:10;OBDH/ MRL;Check RMOxSV;;1;;;;00:10 127:00;OBDH;Disable RNCEV;;1;;;;00:10 125:00;MRL;Confirm MBV closed;;1;;;; 125:00;EGSE;Confirm that all valve switches are in OFF position (Except OxDV & HPDV);;1;;;;00:10 115:00;EGSE/ MRL;Check loadcell by applying force to it;;1;;;;00:20 114:40;OBDH;Check RHPPT shows atmosphere;;1;;;; 114:40;OBDH;Check ROxTPT shows atmosphere;;1;;;; 114:40;OBDH;Check RIHPT shows atmosphere;;1;;;; 114:40;OBDH;Check RCCPT shows atmosphere;;1;;;; 114:40;OBDH;Check RBaro1 shows atmosphere;;1;;;; 114:40;OBDH;Check RBaro2 shows atmosphere;;1;;;; 114:40;EGSE;Check HPPT1 shows 0 bar;;1;;;;00:20 114:20;EGSE;Check HPPT2 shows 0 bar;;1;;;; 114:20;EGSE;Check HPLPT shows 0 bar;;1;;;; 114:20;EGSE;Check OxInPT1 shows 0 bar;;1;;;; 114:20;EGSE;Check OxInPT2 shows 0 bar;;1;;;; 114:20;EGSE;Check OxOutPT shows 0 bar;;1;;;;00:20 114:00;EGSE/ MRL;Switch on N2O coupling & check if magnetic valve LED is on;;1;;;; 114:00;EGSE/ MRL;Switch on He coupling & check if magnetic valve LED is on;;1;;;; 114:00;EGSE/ MRL;Switch on swivle arm & check if magnetic valve LED is on;;1;;;; 114:00;EGSE;Switch off swivel arm & He coupling & N2O coupling;;1;;;;01:00 114:00;MCC;BEGIN SEQUENCE: Ignition signal Test;Ignition signal Test;1;;;;01:00 113:00;MRL;Confirm that Ignition Umbilical is disconnected;;1;;;; 113:00;MRL;Connect Ignition test receptical;;1;;;; 113:00;EGSE @MRL;Plug in Bridges B1 and B2 into EGSE;;1;;;; 113:00;MRL;Confirm Soundsignal from Ignition Umbilical;;1;;;; 113:00;EGSE;Turn on Ignition Secure Switch;;1;;;; 113:00;EGSE/ OBDH;Turn on Ignition Switch for 2 Second & Confirm ignition signal received at sbRio & cRio;;1;;;; 113:00;EGSE;Confirm that Ignition Switch is switched OFF and secured;;1;;;; 113:00;EGSE;Turn off Ignition Secure Switch;;1;;;; 113:00;EGSE @MRL;Remove Bridges B1 and B2;;1;;;; 113:00;MRL;Remove Ignition test receptical;;1;;;;03:00 110:00;MCC;BEGIN SEQUENCE: Ground segment pressure test (PHASE YELLOW) ;GSE Pressure Test;2;LuF, AlS, LeD: 1x Helm, 3x Ear protectors;ChB, FiH, JuL, LiA, MiS;; 130:50;EGSE/ MRL;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;;2;;;;00:10 130:40;EGSE/ MRL;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;2;;;;00:10 109:00;MRL;Confirm He bottle 1 connector is attached;;2;;;; 109:00;MRL;Confirm He bottle 2 connector is attached;;2;;;; 109:00;MRL;Confirm N2O bottle 1 connector is attached;;2;;;; 109:00;MRL;Confirm N2O bottle 2 connector is attached;;2;;;; 109:00;MRL;Confirm hose between HPSM & N2OSM is connected on both ends;;2;;;; 109:00;MRL;Confirm hose between HPSM & Flight Segment is connected on both ends;;2;;;; 109:00;MRL;Confirm hose between N2OSM & Flight Segment is connected on both ends;;2;;;; 109:00;MRL;Confirm pneumatic hose is connected on both ends;;2;;;;02:00 107:00;MRL;Put on safety equipment;;2;;;; 107:00;MRL;Confirm MBV is closed;;2;;;; 107:00;MRL;Confirm HPNV1 is closed;;2;;;; 107:00;MRL;Confirm HPNV2 is closed;;2;;;; 107:00;MRL;Take positions to open He Bottle 1;;2;;;; 107:00;EGSE;Confirm HPV1 is closed;;2;;;; 107:00;EGSE;Confirm MPV1/2 is closed;;2;;;; 107:00;MRL;Open He Bottle 1;;2;;;;01:00 106:00;EGSE/ MRL;Check & compare pressure HPPT1 with HPPG1 (max 300 bar);;2;;;; 106:00;MRL;Check Gastech Silver HPPR1 (max 300 to 50 bar);;2;;;; 106:00;MRL;Check Harris PPR (50 to 8 bar);;2;;;; 106:00;MRL;Check pneumatic PPG (8 bar);;2;;;; 106:00;MRL;Step back;;2;;;;01:00 105:00;EGSE/ MRL;Open & Close HPV1 SHORTLY & Check HPPT1;;2;;;; 105:00;EGSE;Check HPPT1 300 Bar;;2;;;; 105:00;EGSE;Confirm HPLPT 0 Bar;;2;;;; 105:00;EGSE/ MRL;Open & Close HPV2 SHORTLY & Confirm HPPT2 0 bar;;2;;;; 105:00;EGSE/ MRL;Open & Close HPDV SHORTLY & Confirm HPLPT 0 bar;;2;;;; 105:00;EGSE/ MRL;Open & Close OxV1 SHORTLY;;2;;;; 105:00;EGSE/ MRL;Open & Close OxV2 SHORTLY;;2;;;; 105:00;EGSE/ MRL;Open & Close OxDV SHORTLY;;2;;;; 105:00;EGSE/ MRL;Open & Close MPV3 SHORTLY;;2;;;; 0:00;MRL;Open HPNV1 completely;;2;;;; 0:00;MRL;Step Back;;2;;;; 0:00;EGSE;"Open & Close HPV1 STEPWISE untile HPLPT equal to HPPT1 and check for leakage @HPLPT (If leakage occurs proceed to passivation Procedure out of sequence)";;2;;;; 0:00;EGSE;"Confirm RHPPT & RoxTPT 1 Bar (If pressure is higher proceed to passivation Procedure out of sequence);;2;;;; 0:00;EGSE;Open HPV1;;2;;;; 0:00;EGSE;"Open & Close HPV2 STEPWISE untile HPPT2 equal to HPLPT and check for leakage @HPPT2 (If leakage occurs proceed to passivation Procedure out of sequence)";;2;;;; 0:00;EGSE;Close HPV1;;2;;;; 0:00;EGSE;Open STEPWISE HPDV & confirm HPLPT 0 Bar;;2;;;; 0:00;EGSE;Open STEPWISE HPV2 & confirm HPPT2 0 Bar;;2;;;; 0:00;EGSE;Close HPV2;;2;;;; 0:00;EGSE;Close HPDV;;2;;;; 87:10;EGSE;Open & Close STEPWISE MPV1/2 to 50 Bar @ OxInPT1 & OxInPT2;;2;;;; 87:10;EGSE;Confirm MPV1/2 closed;;2;;;; 87:10;EGSE;Open OxDV;;2;;;; 87:10;EGSE;Open & Close STEPWISE MPV3 & Confirm 0 Bar @OxOutPT;;2;;;; 87:10;EGSE;Confirm OxOutPT 0 Bar;;2;;;; 87:10;EGSE;Check OxInPT1 and OxInPT2 for leakage (If leakage occurs proceed to passivation Procedure out of sequence);;2;;;; 87:10;EGSE;Confirm MPV3 closed;;2;;;; 87:10;EGSE;Open & Close STEPWISE OxV1 to 0 Bar @OxInPT1;;2;;;; 87:10;EGSE;Open & Close STEPWISE OxV2 to 0 Bar @OxInPT2;;2;;;; 87:10;EGSE;Confirm OxOutPT 0 Bar;;2;;;; 87:10;EGSE;Close OxDV;;2;;;; 105:00;EGSE;Confirm HPLPT & OxOutPT 0 Bar;;2;;;;01:30 103:30;EGSE;Decouple N2O coupling;;2;;;; 103:30;EGSE;Decouple Helium coupling;;2;;;;00:20 103:10;EGSE;Move arm away from rocket;;2;;;; 103:10;EGSE;Move arm to rocket;;2;;;;01:00 102:10;MRL;Close He Bottle 1 and check HPSM for leakage (If leakage occurs proceed to passivation Procedure out of sequence);;2;;;;01:00 101:10;EGSE;Confirm no high pressures in Ground Segment;;2;;;; 101:10;MRL;Open MBV;;2;;;; 101:10;EGSE/ MRL;Check and compare pressure HPPT1 with HPPG1 0 Bar;;2;;;; 101:10;MRL;Close MBV;;2;;;;00:30 100:40;MRL;Safety is ensured;;2;;;; 100:40;MCC;EGSE @MRL Go to MRL;;1;;;; 100:40;EGSE;Switch OFF N20 coupling;;1;;;; 100:40;EGSE;Switch OFF He coupling;;1;;;; 100:40;MRL;Confirm PPG 0 Bar;;1;;;;00:20 100:40;MRL;Release Pneumatic lines of couplings @HPSM;;1;;;;00:20 100:20;EGSE;Confirm Fueling arm is switched OFF;;1;;;; 100:20;EGSE;Confirm OxOutPT and HPLPT 0 bar;;1;;;; 100:20;MRL;Couple He coupling & Confirm it is connected properly;;1;;;;00:30 99:50;MRL;Couple N2O coupling & Confirm it is connected properly;;1;;;;00:30 100:40;MRL;Reattach Pneumatic Line to Fueling arm @HPSM;;1;;;;00:20 130:50;EGSE/ MRL;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;;1;;;;00:10 130:40;EGSE/ MRL;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;1;;;;00:10 99:20;MCC;HOLD;HOLD;1;;;; 99:20;MCC;CONTINUE AFTER HOLD;;1;;;; 99:20;MCC;BEGIN SEQUENCE: On Board System Test;On Board System Test;2;;;; 130:50;EGSE/ MRL;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;;1;;;;00:10 130:40;EGSE/ MRL;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;1;;;;00:10 99:40;OBDH;Check RDV;;2;;;;00:10 99:20;OBDH;Check RMOxOV;;2;;;;00:10 99:10;OBDH;Check RMOxSV;;2;;;;00:10 99:00;OBDH;Confirm RNCEV is disabled;;2;;;;00:10 0:00;MRL;Confirm working personel is grounded;;2;;;;01:00 0:00;OBDH;Disconnect from sbRio;;1;;;; 0:00;EGSE;Turn ON EPS_BAT (Rocket OFF);;2;;;;01:00 0:00;EGSE @MRL;Insert EPS RADIO SILENCE Bridge (3R);;1;;;; 0:00;EGSE @MRL;Insert MAIN_BAT Bridge (3L);;1;;;; 0:00;EGSE @MRL;Confirm MAIN_BAT LED is ON;;1;;;; 0:00;EGSE @MRL;Insert OBC2_BAT Bridge (4L);;1;;;; 0:00;EGSE @MRL;Confirm OBC2_BAT LED is ON;;1;;;; 0:00;EGSE @MRL;Insert RECOVERY_BAT Bridge (7L);;1;;;; 0:00;EGSE @MRL;Confirm RECOVERY_BAT LED is ON;;1;;;; 0:00;EGSE @MRL;Insert PAYLOAD1 Bridge (5L);;1;;;; 0:00;EGSE @MRL;Confirm PAYLOAD1 LED is OFF;;1;;;; 0:00;EGSE @MRL;Insert PAYLOAD2 Bridge (6L);;1;;;; 0:00;EGSE @MRL;Confirm PAYLOAD2 LED is ON;;1;;;; 0:00;EGSE @MRL;Confirm MAIN_BUS LED is OFF;;1;;;; 0:00;EGSE @MRL;Remove EPS RADIO SILENCE Bridge (3R);;1;;;; 0:00;EGSE;Turn OFF EPS_BAT (Rocket ON);;2;;;;01:00 0:00;EGSE @MRL;Confirm MAIN_BUS LED is ON;;1;;;; 0:00;EGSE @MRL;Confirm 1 beep at Telemega;;1;;;; 0:00;MRL;Confirm 3 beeps at OBC1;;1;;;; 0:00;EGSE @MRL;Remove BLACKBOX2 RADIO SILENCE Bridge (3R);;1;;;; 139:50;OBDH;Connect to sbRio using remote Access utility;;1;;;; 139:50;OBDH;Open RT_Sub_HMI;;1;;;; 139:50;OBDH;Confirm Main Chute button is disabled;;1;;;; 135:40;OBDH;Check EPS hardware Voltages;;1;;;;00:10 0:00;EGSE;Check EGSE Currents;;1;;;;00:10 125:30;PYL;Confirm CanSat is running;;1;;;;00:20 125:30;PYL;Confirm BlackBox2 is running;;1;;;; 125:30;EGSE;Turn OFF EPS_EXT_24V;;1;;;; 125:30;PYL;Confirm CanSat is running;;1;;;;00:20 125:30;PYL;Confirm BlackBox2 is running;;1;;;; 125:30;EGSE;Turn ON EPS_EXT_24V;;1;;;; 0:00;OBDH;Disconnect from sbRio;;1;;;; 99:20;EGSE;Turn ON EPS_BAT (Rocket OFF);;1;;;;01:00 99:20;MCC;BEGIN SEQUENCE: Prime Rocket;Prime Rocket (PHASE YELLOW);2;;;; 99:20;EGSE;Confirm EPS_BAT is ON (Rocket OFF);;2;;;;01:00 99:20;MRL;Confirm working personel is grounded;;2;;;;01:00 99:20;MRL;Confirm that RMDV is closed;;2;;;;01:00 99:00;MRL;Close & secure HP maintenance cover;;2;;;;01:00 99:00;MRL;Close & secure MainOX maintenance cover;;2;;;;01:00 98:50;MRL;Turn on GoPro Camera at end of Launch Rail;;2;;;;00:20 141:20;EGSE @MRL;Confirm ALL 8 bridges on the right side are removed;;1;;;; 141:20;EGSE @MRL;Confirm ALL 8 bridges on the left side are inserted;;1;;;; 95:30;MRL;Close & secure bridge maintenance cover;;2;;;;00:20 99:20;MRL;Confirm spring retracted cover at He coupling is moving freely;;2;;;; 99:20;MRL;Confirm spring retracted cover at N2O coupling is moving freely;;2;;;; 95:00;MRL;Confirm that HP maintenance cover is closed & secured;;2;;;;01:00 95:30;MRL;Confirm bridge maintenance cover is closed & secured;;2;;;;00:20 95:00;MRL;Confirm that MainOX maintenance cover is closed & secured;;2;;;;01:00 95:10;EGSE @MRL;Leave MRL & return to MCC;;2;;;; 99:20;MRL;Connect Ignition Umbilical;;2;;;;00:30 95:10;OPS;Elevate MRL to 90 degrees;;2;;;;05:00 88:40;MCC;BEGIN SEQUENCE: Fueling Preparations (PHASE YELLOW);Fueling Preparations;2;;;; 89:40;EGSE;Zero OxTank Mass;;2;;;;01:00 130:50;EGSE/ MRL;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;;2;;;;00:10 130:40;EGSE/ MRL;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;2;;;;00:10 88:40;MRL;Put on safety equipment;;2;;;;00:30 10:10;MRL;Confirm HPNV1 is Open;;2;;;; 10:10;MRL;Confirm HPNV2 is Closed;;2;;;; 88:10;MRL;Open He Bottle 1;;2;;;;01:00 87:10;MRL;Step back;;2;;;; 0:00;EGSE;"Open & Close HPV1 STEPWISE untile HPLPT equal to HPPT1 and check for leakage @HPLPT (If leakage occurs continue with ""GSE Passivation Procedure"")";;2;;;; 0:00;EGSE;Open HPV1;;2;;;; 0:00;EGSE;"Open & Close HPV2 STEPWISE untile HPPT2 equal to HPLPT and check for leakage @HPPT2 (If leakage occurs continue with ""GSE Passivation Procedure"")";;2;;;; 0:00;EGSE;Close HPV1;;2;;;; 0:00;EGSE;Open STEPWISE HPDV & Confirm HPLPT 0 Bar;;2;;;; 0:00;EGSE;Confirm HPV1 is closed;;2;;;; 0:00;EGSE;Confirm HPV2 is closed;;2;;;; 0:00;EGSE;Close HPDV;;2;;;; 10:10;MRL;Open HPNV2 1/8 Rev;;2;;;; 87:10;EGSE;Open & Close STEPWISE MPV1/2 to 50 Bar @ OxInPT1 & OxInPT2;;2;;;; 87:10;EGSE/ MRL;Check & compare OxInPT1 with OxInPG1 based on Bottle temperature (max 50 bar);;2;;;; 87:10;EGSE/ MRL;Check & compare pressure OxInPT2 with OxInPG2 based on Bottle temperature (max 50 bar);;2;;;; 87:10;EGSE/ MRL;Check Temperature of N2O Bottle 1 @OxT1 & OxWT1 (max 22C);;2;;;; 87:10;EGSE/ MRL;Check Temperature of N2O Bottle 2 @OxT2 & OxWT2 (max 22C);;2;;;;01:30 85:40;MRL;Open He Bottle 2;;2;;;; 85:40;EGSE/ MRL;Check & compare pressure HPPT2 with HPPG2 (max 315 bar);;2;;;;01:00 84:40;ALL/ MRL;CAUTION!;;2;;;; 84:40;MRL;Open N2O Bottle 1;;2;;;; 84:40;MRL/ EGSE;Check & compare pressure OxInPT 1 with OxInPG 1 (max 50 bar);;2;;;;02:00 82:40;MRL;Open N2O Bottle 2;;2;;;; 82:40;MRL/ EGSE;Check & compare pressure OxInPT 2 with OxInPG 2 (max 50 bar);;2;;;;02:00 80:40;MRL;Insert Ignition Bridges B1 and B2 into EGSE;;2;;;;02:00 78:40;MRL;Confirm Soundsignal from Ignition Umbilical;;2;;;; 78:40;MRL;Close ComTerm & Go to Block House;;2;;;; 78:40;MCC;Turn OFF MRL confirm lock;;2;;;; 78:40;ALL;Inform OPS to clear Launch Pad (Tel.: [!!!]);;2;;;;02:00 147:20;WIND;Start wind weighting analysis;;2;;;; 130:50;EGSE;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;;2;;;;00:10 130:40;EGSE;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;2;;;;00:10 68:40;MCC;HOLD;HOLD;2;;;; 68:40;KLP;Start Camera Karsten Lappöhn;;2;;;; 68:40;MCC;CONTINUE AFTER HOLD;;2;;;; 130:50;EGSE;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;;2;;;;00:10 130:40;EGSE;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;2;;;;00:10 130:40;EGSE;Confirm storage capacity of CRio is greater than 300MB;;2;;;;00:10 68:40;MCC;BEGIN SEQUENCE Ox Fueling (PHASE RED);Ox Fueling (PHASE RED);3;;;; 68:50;WIND;Report on weather situation;;3;;;; 68:40;MCC;Announce end of Radio Silence;;3;;;; 68:40;EGSE;Turn OFF EPS_BAT (Rocket ON);;3;;;; 0:00;MCC;Confirm 3 beeps at OBC1;;1;;;; 0:00;OBDH;Connect to sbRio using remote Access utility;;3;;;; 0:00;OBDH;Open RT_Sub_HMI;;3;;;; 0:00;OBDH;Confirm RNCEV is disabled;;3;;;;00:10 0:00;OBDH;Confirm Main Chute button is disabled;;3;;;; 0:00;OBDH;Check EPS hardware Voltages;;3;;;;00:10 0:00;EGSE;Check EGSE Currents;;3;;;;00:10 126:50;OBDH/ TMTC;Confirm RF451-Link;;3;;;;00:20 126:30;TMTC;Confirm GPS-lock;;3;;;;00:20 126:10;TMTC;Confirm Telemega-Link;;3;;;;00:20 125:30;AVC;Turn on main TMTC screen;;3;;;;00:30 125:30;PYL;Confirm CanSat is running;;3;;;;00:20 125:30;PYL;Confirm BlackBox2 is running;;3;;;; 125:30;MCC;Request Permission to begin fueling from OPS;;3;;;;03:00 68:40;OBDH;Acknowledge start of Fueling;;3;;;;01:00 67:40;EGSE;Open & Close HPV1 STEPWISE to 50 Bar @ ROxTPT (stop every 10 bar & check ROxTBT & ROxTTT (approx. ambiente temp);;3;;;; 67:40;EGSE;Confirm OxOutPT 0 Bar to check ROxCV tightness;;3;;;; 67:40;EGSE;Open & Close HPV1 STEPWISE to more than 50 Bar @ RHPPT and confirm ROxTPT 50 Bar;;3;;;; 67:40;EGSE;Confirm HPV1 is closed;;3;;;; 67:40;OBDH;Open RDV SHORTLY, to check tightness @ RHPPT & ROxTPT (If leakages occur continue with Abort Procedure);;3;;;; 67:40;EGSE;Open MPV1/2;;3;;;; 67:40;EGSE;Open & Close MPV3 STEPWISE to 50 Bar @ OxOutPT;;3;;;; 67:40;EGSE;Close MPV1/2;;3;;;; 67:40;EGSE;Check & compare OxOutPT with OxInPT1;;3;;;; 67:40;EGSE;Check if RHPPT & ROxTPT more than OxInPT1, If less Open & Close HPV1;;3;;;; 67:40;EGSE;Zero OxTank Mass;;3;;;; 67:40;MCC;Write down Time;;3;;;; 67:40;EGSE;Open OxV1;;3;;;;04:00 63:40;OBDH;Open & Close RDV STEPWISE until N2O bottle empty or 25kg OxTankMass, keep temperatures RDVT and RDVET above 10°C and Check delta ROxTPT and OxInPT1;;3;;;;30:00:00 33:40;EGSE;Verify Bottle Temperatures @ OxT1, OxT2, HPT2;;3;;;;00:10 33:40;EGSE;Verify Water Temperatures @ Ox@T1, OxWT2, HPWT2;;3;;;;00:10 33:40;EGSE;Close OxV1;;3;;;;00:10 33:30;EGSE;Check if Pressure rises in OxPT1, if Pressure rises relief via OxV1 or wait for Pressure relief valve;;3;;;;01:00 32:30;EGSE;Check & compare OxOutPT with OxInPT2;;3;;;; 32:30;EGSE;Check & compare RHPPT & ROxTPT 50 Bar and more than OxInPT2, If less Open & Close HPV1;;3;;;; 32:30;EGSE;Open OxV2 ;;3;;;; 32:30;OBDH;Open & Close RDV STEPWISE to 25kg OxTankMass, keep temperatures RDVT and RDVET above 10°C and Check delta OxTPT and OxInPT1;;3;;;;20:00 12:30;EGSE;Close OxV2 ;;3;;;;00:10 12:20;EGSE;Check if Pressure rises in OxPT2, if Pressure rises relief via OxV2 or wait for Pressure relief valve;;3;;;;01:00 11:20;EGSE;Open OxDV STEPWISE until OxOutPT 0 Bar;;3;;;; 11:20;OBDH;Check ROxCV for tightness @ ROxTPT;;3;;;; 11:20;EGSE;Close OxDV;;3;;;;01:00 10:20;EGSE;Write down OxTankMass;;3;;;; 33:40;EGSE;Verify He Bottle 2 Temperature @HPT2 & @HPWT2 (turn ON He_Heater if necessary) ;;3;;;;00:10 10:20;MCC;Provide OxTankMass and temperature readings to Wind weighting station Tel[!!!];;3;;;;00:30 9:50;EGSE;Confirm OxV1 & OxV2 closed;;3;;;; 9:50;EGSE;Confirm OxOutPT 0 Bar;;3;;;; 9:50;EGSE;Decouple N2O coupling;;3;;;;00:20 9:30;MCC;Confirm End of Oxidator Fueling to OPS;;3;;;;00:15 9:20;WIND;Start wind weighting analysis;;3;;;; 9:15;OBDH/ TMTC;Check RF451-Link;;3;;;;00:20 8:55;TMTC;Check GPS-lock;;3;;;;00:20 8:35;TMTC;Check Telemega-Link;;3;;;;00:20 33:40;EGSE;Verify He Bottle 2 Temperature @HPT2 & @HPWT2 (turn ON/OFF He_Heater if necessary) ;;3;;;;00:10 8:15;MCC;HOLD (Last possible scheduled HOLD);HOLD;3;;;; 8:15;OPS;Align MRL to Launch Trajectory;;3;;;; 8:15;MCC;Turn audio volume down;;3;;;; 8:15;MCC;Turn OFF ComTerm step delay;;3;;;; 8:15;ALL;Talk through Ignition Sequence;;3;;;; 8:15;MCC;Wait for OPS to confirm final MRL adjustment;;3;;;; 8:15;WIND;Report on weather situation;;3;;;; 8:15;MCC;CONTINUE AFTER HOLD;;3;;;; 8:15;AVC;Start Video recording in Block House;;3;;;; 8:15;EGSE;Verify He Bottle 2 Temperature @HPT2 & @HPWT2 (turn ON/OFF He_Heater if necessary) ;;3;;;;00:10 8:15;MCC;BEGIN SEQUENCE: Switching to Internal Power;Switch to Internal Power;3;;;; 8:15;EGSE;Turn OFF EPS_EXT_24V (Switch to internal Power);;3;;;;00:20 7:55;OBDH;Confirm EPS Voltages are within limits;;3;;;;00:10 7:45;OBDH;Confirm RF451 Transmitting;;3;;;;00:05 7:40;OBDH/ TMTC;Confirm RF451-Link;;3;;;;00:20 7:20;TMTC;Confirm GPS-lock;;3;;;;00:20 7:00;TMTC;Confirm Telemega-Link;;3;;;;00:20 6:40;OBDH;Switch to PREARMED;;3;;;;00:10 6:30;PYL;Confirm Payload is running;;3;;;;00:20 6:30;PYL;Confirm BlackBox2 is ready for launch;;3;;;; 6:10;AVC;Confirm that videorecording @ MCC is running;;3;;;;00:05 6:05;MCC;BEGIN SEQUENCE: High Pressure Fueling;High Pressure Fueling;3;;;; 33:40;EGSE;Verify He Bottle 2 Temperature @HPT2 & @HPWT2 (turn ON/OFF He_Heater if necessary) ;;3;;;;00:10 6:05;EGSE;Open & Close HPV1 STEPWISE until RHPPT 300 Bar or pressure equal to He Bottle 1;;3;;;; 6:05;EGSE;Open & Close HPV2 STEPWISE until RHPPT 300 Bar ;;3;;;; 6:05;EGSE;Open & close HPDV STEPWISE until HPLPT 0 Bar ;;3;;;; 6:05;EGSE;Confirm HPDV closed;;3;;;; 6:05;OBDH/ EGSE;Check for leakage & HPLPT 0 Bar & RHPPT 300 Bar ;;3;;;;02:00 6:05;EGSE;Turn OFF He_Heater;;3;;;; 4:05;OBDH;Acknowledge end of Fueling;;3;;;;00:10 3:55;MCC;Confirm End of High-Pressure Fueling to OPS;;3;;;;00:20 3:35;MCC;BEGIN SEQUENCE: Disconnecting Fueling Arm;Disconnecting Fueling Arm;3;;;;00:10 3:25;EGSE;Confirm HPV1 & HPV2 closed;;3;;;;00:10 3:15;EGSE;Confirm HPLPT 0 Bar ;;3;;;;00:10 3:05;EGSE;Decouple Helium coupling;;3;;;;00:20 2:45;EGSE;Confirm Helium coupling is disconnected;;3;;;;00:10 2:35;EGSE;Move fueling arm away from rocket;;3;;;;00:40 1:55;MCC;Confirm Fueling Arm away to OPS;;3;;;;00:15 1:40;MCC;Prepare for Launch;;3;;;;00:10 1:40;EGSE;Activate High-Speed data recording;;3;;;;00:10 1:30;OBDH;Confirm ready for launch;;3;;;;00:10 1:20;EGSE;Confirm ready for launch;;3;;;;00:10 1:10;MCC;Set Go/No-Go System to Go;;3;;;;00:10 1:00;MCC;Wait for Authorization for Launch;;3;;;;00:00 1:00;MCC;BEGIN SEQUENCE: Ignition;Ignition Sequence;3;;;;00:10 0:50;OBDH;T-50 ARM;;3;;;;00:05 0:40;OBDH;T-40 Confirm all status indicators green;;3;;;;00:05 0:30;OBDH;T-30 Disconnect from sbRio;;3;;;;00:30 0:10;EGSE;T-10 Turn on Ignition Secure;;3;;;;00:07 0:03;EGSE;T-3: Ignition;;3;;;;00:03 0:00;OBDH;T+0: Verify RMOxOV Open (Launched);;3;;;;00:00 0:00;EGSE;T+1: Turn OFF Ignition;;3;;;; 0:00;EGSE;T+5: Turn OFF Ignition Secure;;3;;;; 0:00;OBDH;T+20: Verify RMOxOV Closed and RMOxSV Open (Cruise);;3;;;; 0:00;OBDH;T+50: Verify RNCEV Open (Drogue);;3;;;; 0:00;OBDH;T+310: Verify Main Chute Deployed and RDV Open (Main);;3;;;; 0:00;OBDH;T+600: Verify (Landed);;3;;;; 0:00;MCC;BEGIN SEQUENCE: PASSIVATION (PHASE YELLOW);Passivation;2;;;; 68:40;MCC;Announce BEGIN of Radio Silence;;2;;;; 0:00;MCC;Turn audio volume up;;2;;;; 0:00;MRL;Go to MRL, THEN...;;2;;;; 0:00;MRL;Close N2O Bottle 1 & N2O Bottle 2, THEN...;;2;;;; 0:00;MRL;RETURN to Block House;;2;;;; 0:00;EGSE;Open OxDV;;2;;;; 0:00;EGSE;Open OxV1;;2;;;; 0:00;EGSE;Confirm OxInPT1 & OxOutPT 0 Bar;;2;;;; 0:00;EGSE;Close OxV1;;2;;;; 0:00;EGSE;Open OxV2;;2;;;; 0:00;EGSE;Confirm OxInPT2 & OxOutPT 0 Bar;;2;;;; 0:00;EGSE;Close OxV2;;2;;;; 0:00;EGSE;Close OxDV;;2;;;; 0:00;MRL;Go to MRL, confirm OxInPG1 & OxInPG2 0 Bar, else RETURN to Block House, THEN...;;2;;;; 0:00;MRL;Close He Bottle 2, THEN...;;2;;;; 0:00;MRL;Write down remaining Pressure of He Bottle 2, THEN...;;2;;;; 0:00;MRL;Return to Block House;;2;;;; 0:00;EGSE;Open HPDV;;2;;;; 0:00;EGSE;Open HPV2;;2;;;; 0:00;EGSE;Confirm pressure HPLPT & HPPT2 0 Bar;;2;;;; 0:00;EGSE;Close HPV2;;2;;;; 0:00;EGSE;Close HPDV;;2;;;; 0:00;MRL;Go to MRL, confirm HPPG2 0 Bar, else return to Block House, THEN...;;2;;;; 0:00;MRL;Close He Bottle 1, THEN ...;;2;;;; 0:00;MRL;Open ComTerm;;2;;;; 8:15;MCC;Turn ON ComTerm step delay;;2;;;; 8:00;MCC;Turn OFF MRL confirm lock;;2;;;; 0:00;EGSE/ MRL;Write down remaining Pressure of He Bottle 1;;2;;;; 0:00;MRL;Step back;;2;;;; 0:00;EGSE;Open HPDV;;2;;;; 0:00;EGSE;Open HPV1;;2;;;; 0:00;EGSE;Confirm pressure HPLPT & HPPT1 0 Bar;;2;;;; 0:00;EGSE;Close HPV1;;2;;;; 0:00;EGSE;Close HPDV;;2;;;; 0:00;EGSE;Confirm no high pressures in Ground Segment;;2;;;; 0:00;MRL;Open MBV;;2;;;; 0:00;EGSE/ MRL;Check and compare pressure HPPT1 with HPPG1;;2;;;; 0:00;MRL;Close MBV;;2;;;; 0:00;MRL;Take out B1 & B2 Bridges;;2;;;; 0:00;MRL;Safety is ensured;;2;;;; 0:00;MCC;Confirm to OPS that Safety is ensured;;2;;;; 0:00;MCC;BEGIN SEQUENCE: Data collection;Data collection;1;;;; 0:00;AVC;Turn off GoPro & Camcorder & Stop Block House Video recording;;1;;;; 0:00;EGSE;Copy PID.vi.tdms & save to new name;;1;;;; 0:00;EGSE;Wait for buffer storage process to be finished;;1;;;; 0:00;EGSE;save data files from cRio to PC;;1;;;; 0:00;WIND;Save data on external HDD;;1;;;; 0:00;TMTC;Stop TMTC Vi and save data on external HDD;;1;;;; 0:00;AVC;End audio recording;;1;;;; 0:00;MCC;Stop ComTerm and save logfile to external HDD, THEN...;;1;;;; 0:00;MCC;Restart ComTerm VI;;1;;;; 0:00;AVC;Save video & audio data on external HDD;;1;;;; 0:00;MCC;END OF PROCEDURE;End;1;;;;