changes to maintenance cover closing (added RMDV)

This commit is contained in:
Finn 2020-06-06 13:16:23 +02:00
parent a75a1db781
commit 13276e7df3
3 changed files with 15 additions and 14 deletions

View File

@ -1,4 +1,4 @@
vers.;v4.25;Abort Procedure;;3;mrl;mcc;rdh;time vers.;v4.26;Abort Procedure;;3;mrl;mcc;rdh;time
0:00;MCC;BEGIN SEQUENCE: Defueling Rocket;Defueling;3;;;; 0:00;MCC;BEGIN SEQUENCE: Defueling Rocket;Defueling;3;;;;
0:00;MCC;Inform OPS of Launch Abort;;3;;;; 0:00;MCC;Inform OPS of Launch Abort;;3;;;;
0:00;EGSE;Confirm all valve switches are in OFF position (Except OxDV & HPDV);;3;;;; 0:00;EGSE;Confirm all valve switches are in OFF position (Except OxDV & HPDV);;3;;;;

1 vers. v4.25 v4.26 Abort Procedure 3 mrl mcc rdh time
2 0:00 MCC BEGIN SEQUENCE: Defueling Rocket Defueling 3
3 0:00 MCC Inform OPS of Launch Abort 3
4 0:00 EGSE Confirm all valve switches are in OFF position (Except OxDV & HPDV) 3

View File

@ -1,4 +1,4 @@
vers.;v4.25;Launch Procedure;;0;MRL;MCC;RdHill;Time per step vers.;v4.26;Launch Procedure;;0;MRL;MCC;RdHill;Time per step
147:20;MCC;BEGIN SEQUENCE: Power on EGSE;Power on EGSE;1;;;; 147:20;MCC;BEGIN SEQUENCE: Power on EGSE;Power on EGSE;1;;;;
147:20;WIND;Start wind weighting analysis;;1;;;; 147:20;WIND;Start wind weighting analysis;;1;;;;
147:20;EGSE;Check CLD connection;;1;;;; 147:20;EGSE;Check CLD connection;;1;;;;
@ -149,10 +149,10 @@ vers.;v4.25;Launch Procedure;;0;MRL;MCC;RdHill;Time per step
105:00;EGSE/ MRL;Open & Close MPV3 SHORTLY;;2;;;; 105:00;EGSE/ MRL;Open & Close MPV3 SHORTLY;;2;;;;
0:00;MRL;Open HPNV1 completely;;2;;;; 0:00;MRL;Open HPNV1 completely;;2;;;;
0:00;MRL;Step Back;;2;;;; 0:00;MRL;Step Back;;2;;;;
0:00;EGSE;"Open & Close HPV1 STEPWISE untile HPLPT equal to HPPT1 and check for leakage @HPLPT (If leakage occurs continue with ""GSE Passivation Procedure"")";;2;;;; 0:00;EGSE;"Open & Close HPV1 STEPWISE untile HPLPT equal to HPPT1 and check for leakage @HPLPT (If leakage occurs proceed to passivation Procedure out of sequence)";;2;;;;
0:00;EGSE;"Confirm RHPPT & RoxTPT 1 Bar (on Pressure continue with ""Rocket Passivation Procedure"")";;2;;;; 0:00;EGSE;"Confirm RHPPT & RoxTPT 1 Bar (If pressure is higher proceed to passivation Procedure out of sequence);;2;;;;
0:00;EGSE;Open HPV1;;2;;;; 0:00;EGSE;Open HPV1;;2;;;;
0:00;EGSE;"Open & Close HPV2 STEPWISE untile HPPT2 equal to HPLPT and check for leakage @HPPT2 (If leakage occurs continue with ""GSE Passivation Procedure"")";;2;;;; 0:00;EGSE;"Open & Close HPV2 STEPWISE untile HPPT2 equal to HPLPT and check for leakage @HPPT2 (If leakage occurs proceed to passivation Procedure out of sequence)";;2;;;;
0:00;EGSE;Close HPV1;;2;;;; 0:00;EGSE;Close HPV1;;2;;;;
0:00;EGSE;Open HPDV & confirm HPLPT 0 Bar;;2;;;; 0:00;EGSE;Open HPDV & confirm HPLPT 0 Bar;;2;;;;
0:00;EGSE;Open HPV2 & confirm HPPT2 0 Bar;;2;;;; 0:00;EGSE;Open HPV2 & confirm HPPT2 0 Bar;;2;;;;
@ -162,7 +162,7 @@ vers.;v4.25;Launch Procedure;;0;MRL;MCC;RdHill;Time per step
87:10;EGSE;Confirm MPV1/2 closed;;2;;;; 87:10;EGSE;Confirm MPV1/2 closed;;2;;;;
87:10;EGSE;Open OxDV;;2;;;; 87:10;EGSE;Open OxDV;;2;;;;
87:10;EGSE;Open & Close STEPWISE MPV3 to 0 Bar @OxOutPT;;2;;;; 87:10;EGSE;Open & Close STEPWISE MPV3 to 0 Bar @OxOutPT;;2;;;;
87:10;EGSE;Check OxInPT1 and OxInPT2 for leakage (If leakage occurs proceed to GSE passivation Procedure);;2;;;; 87:10;EGSE;Check OxInPT1 and OxInPT2 for leakage (If leakage occurs proceed to passivation Procedure out of sequence);;2;;;;
87:10;EGSE;Confirm MPV3 closed;;2;;;; 87:10;EGSE;Confirm MPV3 closed;;2;;;;
87:10;EGSE;Open & Close STEPWISE OxV1 to 0 Bar @OxInPT1;;2;;;; 87:10;EGSE;Open & Close STEPWISE OxV1 to 0 Bar @OxInPT1;;2;;;;
87:10;EGSE;Open & Close STEPWISE OxV2 to 0 Bar @OxInPT2;;2;;;; 87:10;EGSE;Open & Close STEPWISE OxV2 to 0 Bar @OxInPT2;;2;;;;
@ -173,12 +173,10 @@ vers.;v4.25;Launch Procedure;;0;MRL;MCC;RdHill;Time per step
103:30;EGSE;Decouple Helium coupling;;2;;;;00:20 103:30;EGSE;Decouple Helium coupling;;2;;;;00:20
103:10;EGSE;Move arm away from rocket;;2;;;; 103:10;EGSE;Move arm away from rocket;;2;;;;
103:10;EGSE;Move arm to rocket;;2;;;;01:00 103:10;EGSE;Move arm to rocket;;2;;;;01:00
102:10;MRL;Close He Bottle 1 and check HPSM for leakage (If leakage occurs continue with Passivation Procedure);;2;;;;01:00 102:10;MRL;Close He Bottle 1 and check HPSM for leakage (If leakage occurs proceed to passivation Procedure out of sequence);;2;;;;01:00
101:10;MRL;Open MBV;;2;;;; 101:10;MRL;Open MBV;;2;;;;
101:10;EGSE/ MRL;Check and compare pressure HPPT1 with HPPG1 0 Bar;;2;;;; 101:10;EGSE/ MRL;Check and compare pressure HPPT1 with HPPG1 0 Bar;;2;;;;
101:10;MRL;Close MBV;;2;;;;00:30 101:10;MRL;Close MBV;;2;;;;00:30
100:40;MRL;Open RMDV & relief pressure;;2;;;;
100:40;MRL;Close RMDV;;2;;;;
100:40;MRL;Safety is ensured;;2;;;; 100:40;MRL;Safety is ensured;;2;;;;
100:40;MCC;EGSE @MRL to MRL;;1;;;; 100:40;MCC;EGSE @MRL to MRL;;1;;;;
100:40;EGSE;Switch OFF N20 coupling;;1;;;; 100:40;EGSE;Switch OFF N20 coupling;;1;;;;
@ -206,15 +204,18 @@ vers.;v4.25;Launch Procedure;;0;MRL;MCC;RdHill;Time per step
99:00;OBDH;Disable RNCEV;;2;;;;00:10 99:00;OBDH;Disable RNCEV;;2;;;;00:10
99:20;EGSE;Turn ON EPS_BAT (Rocket OFF);;2;;;;01:00 99:20;EGSE;Turn ON EPS_BAT (Rocket OFF);;2;;;;01:00
99:20;MRL;Confirm working personel is grounded;;2;;;;01:00 99:20;MRL;Confirm working personel is grounded;;2;;;;01:00
110:00;MRL;Confirm that HP maintenance cover is closed & secured;;2;;;;01:00 99:20;MRL;Confirm that RMDV is closed;;2;;;;01:00
110:00;MRL;Confirm that MainOX maintenance cover is closed & secured;;2;;;;01:00 99:00;MRL;Close & secure HP maintenance cover;;2;;;;01:00
99:20;MRL;Confirm spring retracted cover at He coupling is moving freely;;2;;;; 99:00;MRL;Close & secure MainOX maintenance cover;;2;;;;01:00
99:20;MRL;Confirm spring retracted cover at N2O coupling is moving freely;;2;;;;
98:50;MRL;Turn on GoPro Camera at end of Launch Rail;;2;;;;00:20 98:50;MRL;Turn on GoPro Camera at end of Launch Rail;;2;;;;00:20
99:20;MRL;Connect Ignition Umbilical;;2;;;;00:30 99:20;MRL;Connect Ignition Umbilical;;2;;;;00:30
98:30;MRL;Insert all EPS Bridges;;2;;;;03:00 98:30;MRL;Insert all EPS Bridges;;2;;;;03:00
95:30;MRL;Close bridge maintenance cover;;2;;;;00:20 95:30;MRL;Close bridge maintenance cover;;2;;;;00:20
99:20;MRL;Confirm spring retracted cover at He coupling is moving freely;;2;;;;
99:20;MRL;Confirm spring retracted cover at N2O coupling is moving freely;;2;;;;
95:00;MRL;Confirm that HP maintenance cover is closed & secured;;2;;;;01:00
95:30;MRL;Confirm bridge maintenance cover is closed & secured;;2;;;;00:20 95:30;MRL;Confirm bridge maintenance cover is closed & secured;;2;;;;00:20
95:00;MRL;Confirm that MainOX maintenance cover is closed & secured;;2;;;;01:00
95:10;EGSE @MRL;return to MCC;;2;;;; 95:10;EGSE @MRL;return to MCC;;2;;;;
95:10;OPS;Elevate MRL to 90 degrees;;2;;;;05:00 95:10;OPS;Elevate MRL to 90 degrees;;2;;;;05:00
89:40;EGSE;Zero OxTank Mass;;2;;;;01:00 89:40;EGSE;Zero OxTank Mass;;2;;;;01:00

Can't render this file because it contains an unexpected character in line 155 and column 11.

View File

@ -1,4 +1,4 @@
vers.;v4.25;Passivation out of sequence Procedure;;2;mrl;mcc;rdh;time vers.;v4.26;Passivation out of sequence Procedure;;2;mrl;mcc;rdh;time
0:00;MCC;BEGIN SEQUENCE: Prepare Passivation Sequence;Prepare Passivation;2;;;; 0:00;MCC;BEGIN SEQUENCE: Prepare Passivation Sequence;Prepare Passivation;2;;;;
0:00;MCC/MRL;Recall and make sure BOTH N2O Bottles & He Bottle 2 are still closed! Else continue with Abort Procedure;;2;;;; 0:00;MCC/MRL;Recall and make sure BOTH N2O Bottles & He Bottle 2 are still closed! Else continue with Abort Procedure;;2;;;;
0:00;MCC;Inform OPS of Passivation out of sequence;;2;;;; 0:00;MCC;Inform OPS of Passivation out of sequence;;2;;;;

1 vers. v4.25 v4.26 Passivation out of sequence Procedure 2 mrl mcc rdh time
2 0:00 MCC BEGIN SEQUENCE: Prepare Passivation Sequence Prepare Passivation 2
3 0:00 MCC/MRL Recall and make sure BOTH N2O Bottles & He Bottle 2 are still closed! Else continue with Abort Procedure 2
4 0:00 MCC Inform OPS of Passivation out of sequence 2