|
|
|
@ -1,4 +1,4 @@
|
|
|
|
|
vers.;v4.25;Launch Procedure;;0;MRL;MCC;RdHill;Time per step
|
|
|
|
|
vers.;v4.26;Launch Procedure;;0;MRL;MCC;RdHill;Time per step
|
|
|
|
|
147:20;MCC;BEGIN SEQUENCE: Power on EGSE;Power on EGSE;1;;;;
|
|
|
|
|
147:20;WIND;Start wind weighting analysis;;1;;;;
|
|
|
|
|
147:20;EGSE;Check CLD connection;;1;;;;
|
|
|
|
@ -149,10 +149,10 @@ vers.;v4.25;Launch Procedure;;0;MRL;MCC;RdHill;Time per step
|
|
|
|
|
105:00;EGSE/ MRL;Open & Close MPV3 SHORTLY;;2;;;;
|
|
|
|
|
0:00;MRL;Open HPNV1 completely;;2;;;;
|
|
|
|
|
0:00;MRL;Step Back;;2;;;;
|
|
|
|
|
0:00;EGSE;"Open & Close HPV1 STEPWISE untile HPLPT equal to HPPT1 and check for leakage @HPLPT (If leakage occurs continue with ""GSE Passivation Procedure"")";;2;;;;
|
|
|
|
|
0:00;EGSE;"Confirm RHPPT & RoxTPT 1 Bar (on Pressure continue with ""Rocket Passivation Procedure"")";;2;;;;
|
|
|
|
|
0:00;EGSE;"Open & Close HPV1 STEPWISE untile HPLPT equal to HPPT1 and check for leakage @HPLPT (If leakage occurs proceed to passivation Procedure out of sequence)";;2;;;;
|
|
|
|
|
0:00;EGSE;"Confirm RHPPT & RoxTPT 1 Bar (If pressure is higher proceed to passivation Procedure out of sequence);;2;;;;
|
|
|
|
|
0:00;EGSE;Open HPV1;;2;;;;
|
|
|
|
|
0:00;EGSE;"Open & Close HPV2 STEPWISE untile HPPT2 equal to HPLPT and check for leakage @HPPT2 (If leakage occurs continue with ""GSE Passivation Procedure"")";;2;;;;
|
|
|
|
|
0:00;EGSE;"Open & Close HPV2 STEPWISE untile HPPT2 equal to HPLPT and check for leakage @HPPT2 (If leakage occurs proceed to passivation Procedure out of sequence)";;2;;;;
|
|
|
|
|
0:00;EGSE;Close HPV1;;2;;;;
|
|
|
|
|
0:00;EGSE;Open HPDV & confirm HPLPT 0 Bar;;2;;;;
|
|
|
|
|
0:00;EGSE;Open HPV2 & confirm HPPT2 0 Bar;;2;;;;
|
|
|
|
@ -162,7 +162,7 @@ vers.;v4.25;Launch Procedure;;0;MRL;MCC;RdHill;Time per step
|
|
|
|
|
87:10;EGSE;Confirm MPV1/2 closed;;2;;;;
|
|
|
|
|
87:10;EGSE;Open OxDV;;2;;;;
|
|
|
|
|
87:10;EGSE;Open & Close STEPWISE MPV3 to 0 Bar @OxOutPT;;2;;;;
|
|
|
|
|
87:10;EGSE;Check OxInPT1 and OxInPT2 for leakage (If leakage occurs proceed to GSE passivation Procedure);;2;;;;
|
|
|
|
|
87:10;EGSE;Check OxInPT1 and OxInPT2 for leakage (If leakage occurs proceed to passivation Procedure out of sequence);;2;;;;
|
|
|
|
|
87:10;EGSE;Confirm MPV3 closed;;2;;;;
|
|
|
|
|
87:10;EGSE;Open & Close STEPWISE OxV1 to 0 Bar @OxInPT1;;2;;;;
|
|
|
|
|
87:10;EGSE;Open & Close STEPWISE OxV2 to 0 Bar @OxInPT2;;2;;;;
|
|
|
|
@ -173,12 +173,10 @@ vers.;v4.25;Launch Procedure;;0;MRL;MCC;RdHill;Time per step
|
|
|
|
|
103:30;EGSE;Decouple Helium coupling;;2;;;;00:20
|
|
|
|
|
103:10;EGSE;Move arm away from rocket;;2;;;;
|
|
|
|
|
103:10;EGSE;Move arm to rocket;;2;;;;01:00
|
|
|
|
|
102:10;MRL;Close He Bottle 1 and check HPSM for leakage (If leakage occurs continue with Passivation Procedure);;2;;;;01:00
|
|
|
|
|
102:10;MRL;Close He Bottle 1 and check HPSM for leakage (If leakage occurs proceed to passivation Procedure out of sequence);;2;;;;01:00
|
|
|
|
|
101:10;MRL;Open MBV;;2;;;;
|
|
|
|
|
101:10;EGSE/ MRL;Check and compare pressure HPPT1 with HPPG1 0 Bar;;2;;;;
|
|
|
|
|
101:10;MRL;Close MBV;;2;;;;00:30
|
|
|
|
|
100:40;MRL;Open RMDV & relief pressure;;2;;;;
|
|
|
|
|
100:40;MRL;Close RMDV;;2;;;;
|
|
|
|
|
100:40;MRL;Safety is ensured;;2;;;;
|
|
|
|
|
100:40;MCC;EGSE @MRL to MRL;;1;;;;
|
|
|
|
|
100:40;EGSE;Switch OFF N20 coupling;;1;;;;
|
|
|
|
@ -206,15 +204,18 @@ vers.;v4.25;Launch Procedure;;0;MRL;MCC;RdHill;Time per step
|
|
|
|
|
99:00;OBDH;Disable RNCEV;;2;;;;00:10
|
|
|
|
|
99:20;EGSE;Turn ON EPS_BAT (Rocket OFF);;2;;;;01:00
|
|
|
|
|
99:20;MRL;Confirm working personel is grounded;;2;;;;01:00
|
|
|
|
|
110:00;MRL;Confirm that HP maintenance cover is closed & secured;;2;;;;01:00
|
|
|
|
|
110:00;MRL;Confirm that MainOX maintenance cover is closed & secured;;2;;;;01:00
|
|
|
|
|
99:20;MRL;Confirm spring retracted cover at He coupling is moving freely;;2;;;;
|
|
|
|
|
99:20;MRL;Confirm spring retracted cover at N2O coupling is moving freely;;2;;;;
|
|
|
|
|
99:20;MRL;Confirm that RMDV is closed;;2;;;;01:00
|
|
|
|
|
99:00;MRL;Close & secure HP maintenance cover;;2;;;;01:00
|
|
|
|
|
99:00;MRL;Close & secure MainOX maintenance cover;;2;;;;01:00
|
|
|
|
|
98:50;MRL;Turn on GoPro Camera at end of Launch Rail;;2;;;;00:20
|
|
|
|
|
99:20;MRL;Connect Ignition Umbilical;;2;;;;00:30
|
|
|
|
|
98:30;MRL;Insert all EPS Bridges;;2;;;;03:00
|
|
|
|
|
95:30;MRL;Close bridge maintenance cover;;2;;;;00:20
|
|
|
|
|
99:20;MRL;Confirm spring retracted cover at He coupling is moving freely;;2;;;;
|
|
|
|
|
99:20;MRL;Confirm spring retracted cover at N2O coupling is moving freely;;2;;;;
|
|
|
|
|
95:00;MRL;Confirm that HP maintenance cover is closed & secured;;2;;;;01:00
|
|
|
|
|
95:30;MRL;Confirm bridge maintenance cover is closed & secured;;2;;;;00:20
|
|
|
|
|
95:00;MRL;Confirm that MainOX maintenance cover is closed & secured;;2;;;;01:00
|
|
|
|
|
95:10;EGSE @MRL;return to MCC;;2;;;;
|
|
|
|
|
95:10;OPS;Elevate MRL to 90 degrees;;2;;;;05:00
|
|
|
|
|
89:40;EGSE;Zero OxTank Mass;;2;;;;01:00
|
|
|
|
|