must be checked

This commit is contained in:
Finn 2020-06-03 11:17:01 +02:00
parent 585dd96d6b
commit 5b2be1bb18
1 changed files with 50 additions and 50 deletions

View File

@ -1,4 +1,4 @@
vers.;v4.10;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
vers.;v4.11;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
147:20;WIND;Start wind weighting analysis;;1;;;;;
147:20;MCC;BEGIN SEQUENCE: Power on EGSE;Power on EGSE;1;;;;;
147:20;EGSE;Check CLD connection;;1;;;;;
@ -114,7 +114,7 @@ vers.;v4.10;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
113:00;EGSE;Turn off Ignition Secure Switch;;1;;;;;
113:00;EGSE@MRL;Remove Bridges B1 and B2;;1;;;;;
113:00;MRL;Remove Ignition test receptical;;1;;;;03:00;
110:00;MCC;BEGIN SEQUENCE: Ground segment pressure test (PHASE YELLOW) ;GSE Pressure Test;1;;;;;
110:00;MCC;BEGIN SEQUENCE: Ground segment pressure test (PHASE YELLOW) ;GSE Pressure Test;1;LuF, AlS, LeD: 1x Helm, 3x Ear protectors;ChB, FiH, JuL, LiA, MiS;;;
130:50;EGSE /MRL;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;;1;;;;00:10;
130:40;EGSE /MRL;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;1;;;;00:10;
110:00;MRL;Confirm that all hatches are closed;;1;;;;01:00;
@ -160,8 +160,8 @@ vers.;v4.10;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
00:00;EGSE;Open HPV2 & confirm HPPT2 0 Bar;;2;;;;;
00:00;EGSE;Close HPV2;;2;;;;;
00:00;EGSE;Close HPDV;;2;;;;;
87:10;EGSE;Open & Close STEPWISE MPV1/MPV2 to 50 Bar @ OxInPT1 & OxInPT2;;2;;;;;
87:10;EGSE;Confirm MPV1/MPV2 closed;;2;;;;;
87:10;EGSE;Open & Close STEPWISE MPV1/2 to 50 Bar @ OxInPT1 & OxInPT2;;2;;;;;
87:10;EGSE;Confirm MPV1/2 closed;;2;;;;;
87:10;EGSE;Open OxDV;;2;;;;;
87:10;EGSE;Open & Close STEPWISE MPV3 to 0 Bar @OxOutPT;;2;;;;;
87:10;EGSE;Check OxInPT1 and OxInPT2 for leakage (If leakage occurs proceed to "GSE passivation Procedure";;2;;;;;
@ -233,7 +233,7 @@ vers.;v4.10;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
00:00;EGSE;Confirm HPV2 is closed;;2;;;;;
10:10;MRL;Open HPNV2 1/8 Rev;;2;;;;;
00:00;EGSE;Close HPDV;;2;;;;;
87:10;EGSE;Open & Close STEPWISE MPV1/MPV2 to 50 Bar @ OxInPT1 & OxInPT2;;2;;;;;
87:10;EGSE;Open & Close STEPWISE MPV1/2 to 50 Bar @ OxInPT1 & OxInPT2;;2;;;;;
87:10;EGSE/ MRL;Check & compare OxInPT1 with OxInPG1 based on Bottle temperature (max 50 bar);;2;;;;;
87:10;EGSE/ MRL;Check & compare pressure OxInPT2 with OxInPG2 based on Bottle temperature (max 50 bar);;2;;;;;
87:10;EGSE/ MRL;Check Temperature of N2O Bottle 1 @OxT1 & OxWT1 (max 22C);;2;;;;;
@ -276,9 +276,9 @@ vers.;v4.10;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
67:40;EGSE;Open & Close HPV1 STEPWISE to more than 50 Bar @ RHPPT and confirm ROxTPT 50 Bar;;3;;;;;
67:40;EGSE;Confirm HPV1 is closed;;3;;;;;
67:40;OBDH;Open RDV SHORTLY, to check tightness @ RHPPT & ROxTPT (If leakages occur continue with Abort Procedure);;3;;;;;
67:40;EGSE;Open MPV1/MPV2;;3;;;;;
67:40;EGSE;Open MPV1/2;;3;;;;;
67:40;EGSE;Open & Close MPV3 STEPWISE to 50 Bar @ OxOutPT;;3;;;;;
67:40;EGSE;Close MPV1/MPV2;;3;;;;;
67:40;EGSE;Close MPV1/2;;3;;;;;
67:40;EGSE;Check & compare OxOutPT with OxInPT1;;3;;;;;
67:40;EGSE;Check if RHPPT & ROxTPT more than OxInPT1, If less Open & Close HPV1;;3;;;;;
67:40;EGSE;Zero OxTank Mass;;3;;;;;

Can't render this file because it has a wrong number of fields in line 151.