semantic changes to all Procedures and renaming of Sequences in Passivation OOS
This commit is contained in:
parent
3ecba754af
commit
b3f3815b07
|
@ -1,6 +1,6 @@
|
|||
vers.;v4.20;Abort Procedure;;3;;;;;
|
||||
vers.;v4.22;Abort Procedure;;3;;;;;
|
||||
0:00;MCC;BEGIN SEQUENCE: Defueling Rocket;Defueling;3;;;;;
|
||||
0:00;MCC;Inform OPS of Launch Abort;;3;;;;;
|
||||
0:00;MCC;BEGIN:Defueling Rocket;Defueling;3;;;;;
|
||||
0:00;EGSE;Confirm all valve switches are in OFF position (Except OxDV & HPDV);;3;;;;;
|
||||
0:00;OBDH;Confirm all valve switches are in OFF position (Except RMOxSV);;3;;;;;
|
||||
0:00;OBDH;Activate Heizi;;3;;;;;
|
||||
|
@ -17,7 +17,7 @@ vers.;v4.20;Abort Procedure;;3;;;;;
|
|||
0:00;OBDH;Confirm ROxTPT & RHPPT 1 Bar, if more: Open & Close stepwise RDV;;3;;;;;
|
||||
0:00;OBDH;Deactivate Heizi;;3;;;;;
|
||||
0:00;ALL;Wait for Launchpad to be clear of N2O fumes depending on OxMass before Defueling;;3;;;;;
|
||||
0:00;MCC;BEGIN: ground segment passivation;GSE Passivation;3;;;;;
|
||||
0:00;MCC;BEGIN SEQUENCE: Ground support equipment passivation;GSE Passivation;3;;;;;
|
||||
0:00;MCC;Announce BEGIN of Radio Silence;;3;;;;;
|
||||
0:00;MRL;Go to MRL, Close N2O Bottle 1 & N2O Bottle 2, THEN...;;2;;;;;
|
||||
0:00;MRL;RETURN to Block House;;2;;;;;
|
||||
|
@ -68,4 +68,4 @@ vers.;v4.20;Abort Procedure;;3;;;;;
|
|||
0:00;MCC;Stop ComTerm and save logfile to external HDD, THEN...;;1;;;;;
|
||||
0:00;MCC;Restart ComTerm VI;;1;;;;;
|
||||
0:00;AVC;Save video & audio data on external HDD;;1;;;;;
|
||||
0:00;MCC;END OF PROCEDURE;;1;;;;;
|
||||
0:00;MCC;END OF PROCEDURE;END;1;;;;;
|
||||
|
|
Can't render this file because it has a wrong number of fields in line 32.
|
|
@ -1,6 +1,6 @@
|
|||
vers.;v4.20;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
|
||||
147:20;WIND;Start wind weighting analysis;;1;;;;;
|
||||
vers.;v4.22;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
|
||||
147:20;MCC;BEGIN SEQUENCE: Power on EGSE;Power on EGSE;1;;;;;
|
||||
147:20;WIND;Start wind weighting analysis;;1;;;;;
|
||||
147:20;EGSE;Check CLD connection;;1;;;;;
|
||||
147:20;EGSE;Switch ON CLD via Battery & check voltage (24 Volt);;1;;;;;
|
||||
147:20;EGSE;Switch ON the primary and secondary supply switches on the Control Panel;;1;;;;01:00;
|
||||
|
@ -378,8 +378,8 @@ vers.;v4.20;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
|
|||
0:00;EGSE;Open OxV2;;2;;;;;
|
||||
0:00;EGSE;Confirm OxInPT2 & OxOutPT 0 Bar;;2;;;;;
|
||||
0:00;EGSE;Close OxV2;;2;;;;;
|
||||
0:00;EGSE;Close OxDV ;;2;;;;;
|
||||
0:00;MRL;Go to MRL, confirm OxInPG1 & OxInPG2 0 Bar, else RETURN to Block House, THEN...
|
||||
0:00;EGSE;Close OxDV;;2;;;;;
|
||||
0:00;MRL;Go to MRL, confirm OxInPG1 & OxInPG2 0 Bar, else RETURN to Block House, THEN...;;2;;;;;
|
||||
0:00;MRL;Close He Bottle 2, THEN...;;2;;;;;
|
||||
0:00;MRL;Write down remaining Pressure of He Bottle 2, THEN...;;2;;;;;
|
||||
0:00;MRL;Return to Block House;;2;;;;;
|
||||
|
@ -417,4 +417,4 @@ vers.;v4.20;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
|
|||
0:00;MCC;Stop ComTerm and save logfile to external HDD, THEN...;;1;;;;;
|
||||
0:00;MCC;Restart ComTerm VI;;1;;;;;
|
||||
0:00;AVC;Save video & audio data on external HDD;;1;;;;;
|
||||
0:00;MCC;END OF PROCEDURE;;1;;;;;
|
||||
0:00;MCC;END OF PROCEDURE;End;1;;;;;
|
||||
|
|
Can't render this file because it has a wrong number of fields in line 16.
|
|
@ -1,9 +1,11 @@
|
|||
vers.;v4.20;Passivation out of sequence Procedure;;2;;;;;
|
||||
vers.;v4.22;Passivation out of sequence Procedure;;2;;;;;
|
||||
0:00;MCC;BEGIN SEQUENCE: Prepare Passivation Sequence;Prepare Passivation;2;;;;;
|
||||
0:00;MCC/MRL;Recall and make sure BOTH N2O Bottles & He Bottle 2 are still closed! Else continue with Abort Procedure;;2;;;;;
|
||||
0:00;MCC;Inform OPS of Passivation out of sequence;;2;;;;;
|
||||
0:00;MRL;Step Back/Leave MRL;;2;;;;;
|
||||
0:00;EGSE;Confirm all valve switches are in OFF position (Except OxDV & HPDV);;2;;;;;
|
||||
0:00;OBDH;Confirm all valve switches are in OFF position (Except RMOxSV);;2;;;;;
|
||||
0:00;MCC;BEGIN SEQUENCE: Passivation of GSE;Passivation of GSE;2;;;;;
|
||||
0:00;EGSE;Open & Close OxDV STEPWISE until OxOutPT 0 Bar;;2;;;;;
|
||||
0:00;EGSE;Open OxDV;;2;;;;;
|
||||
0:00;EGSE;Open MPV3;;2;;;;;
|
||||
|
@ -22,14 +24,14 @@ vers.;v4.20;Passivation out of sequence Procedure;;2;;;;;
|
|||
0:00;EGSE;Confirm HPLPT & HPPT2 0 bar;;2;;;;;
|
||||
0:00;EGSE;Close HPV2;;2;;;;;
|
||||
0:00;EGSE;Close HPDV;;2;;;;;
|
||||
0:00;OBDH;Check RHPPT & ROxTPT 1 Bar (If more: continue with Passivation of Rocket, else continue with Passivation of GSE);;2;;;;
|
||||
0:00;OBDH;Check RHPPT & ROxTPT 1 Bar (If more: continue with Passivation of Rocket, else continue at Finish Passivation);;2;;;;
|
||||
0:00;MCC;BEGIN:Passivation of Rocket;Passivation of Rocket;2;;;;;
|
||||
0:00;OBDH;Open & Close stepwise RDV until RHPPT & ROxTPT 1 Bar;;2;;;;;
|
||||
0:00;OBDH;Confirm RHPPT & ROxTPT 1 Bar;;2;;;;;
|
||||
0:00;MRL;Go to MRL;;2;;;;;
|
||||
0:00;MRL;Remove HP section maintenance cover;;2;;;;;
|
||||
0:00;MRL;Open RMDV & Step Back, Wait until NCE-Tank is pressureless;;2;;;;;
|
||||
0:00;MCC;BEGIN:Passivation of GSE;Passivation of GSE;2;;;;;
|
||||
0:00;MCC;BEGIN SEQUENCE: Finish Passivation;Finish Passivation;2;;;;;
|
||||
0:00;MRL;Go to MRL;;2;;;;;
|
||||
0:00;MRL;Close He Bottle 1;;2;;;;;
|
||||
0:00;MCC/MRL;Write down remaining Pressure of He Bottle 1;;2;;;;;
|
||||
|
|
Can't render this file because it has a wrong number of fields in line 27.
|
Loading…
Reference in New Issue