added close RMDV to abort procedure and split up steps in Passivation procedure THEN...

This commit is contained in:
Finn 2020-06-06 13:24:45 +02:00
parent 13276e7df3
commit b424c30c49
3 changed files with 10 additions and 5 deletions

View File

@ -1,4 +1,4 @@
vers.;v4.26;Abort Procedure;;3;mrl;mcc;rdh;time
vers.;v4.27;Abort Procedure;;3;mrl;mcc;rdh;time
0:00;MCC;BEGIN SEQUENCE: Defueling Rocket;Defueling;3;;;;
0:00;MCC;Inform OPS of Launch Abort;;3;;;;
0:00;EGSE;Confirm all valve switches are in OFF position (Except OxDV & HPDV);;3;;;;
@ -18,8 +18,12 @@ vers.;v4.26;Abort Procedure;;3;mrl;mcc;rdh;time
0:00;OBDH;Deactivate Heizi;;3;;;;
0:00;ALL;Wait for Launchpad to be clear of N2O fumes depending on OxMass before Defueling;;3;;;;
0:00;MCC;BEGIN SEQUENCE: Ground support equipment passivation;GSE Passivation;3;;;;
0:00;EGSE;Turn ON EPS_BAT (Rocket OFF);;2;;;;
0:00;MCC;Announce BEGIN of Radio Silence;;3;;;;
0:00;MRL;Go to MRL, Close N2O Bottle 1 & N2O Bottle 2, THEN...;;2;;;;
0:00;MRL;Go to MRL, THEN...;;2;;;;
0:00;MRL;Remove HP section maintenance cover, THEN...;;2;;;;
0:00;MRL;Open RMDV & Step Back, Wait until NCE-Tank is pressureless, THEN...;;2;;;;
0:00;MRL;Close N2O Bottle 1 & N2O Bottle 2, THEN...;;2;;;;
0:00;MRL;RETURN to Block House;;2;;;;
0:00;EGSE;Open OxDV;;2;;;;
0:00;EGSE;Open OxV1;;2;;;;

1 vers. v4.26 v4.27 Abort Procedure 3 mrl mcc rdh time
2 0:00 MCC BEGIN SEQUENCE: Defueling Rocket Defueling 3
3 0:00 MCC Inform OPS of Launch Abort 3
4 0:00 EGSE Confirm all valve switches are in OFF position (Except OxDV & HPDV) 3
18 0:00 OBDH Deactivate Heizi 3
19 0:00 ALL Wait for Launchpad to be clear of N2O fumes depending on OxMass before Defueling 3
20 0:00 MCC BEGIN SEQUENCE: Ground support equipment passivation GSE Passivation 3
21 0:00 EGSE Turn ON EPS_BAT (Rocket OFF) 2
22 0:00 MCC Announce BEGIN of Radio Silence 3
23 0:00 MRL Go to MRL, Close N2O Bottle 1 & N2O Bottle 2, THEN... Go to MRL, THEN... 2
24 0:00 MRL Remove HP section maintenance cover, THEN... 2
25 0:00 MRL Open RMDV & Step Back, Wait until NCE-Tank is pressureless, THEN... 2
26 0:00 MRL Close N2O Bottle 1 & N2O Bottle 2, THEN... 2
27 0:00 MRL RETURN to Block House 2
28 0:00 EGSE Open OxDV 2
29 0:00 EGSE Open OxV1 2

View File

@ -1,4 +1,4 @@
vers.;v4.26;Launch Procedure;;0;MRL;MCC;RdHill;Time per step
vers.;v4.27;Launch Procedure;;0;MRL;MCC;RdHill;Time per step
147:20;MCC;BEGIN SEQUENCE: Power on EGSE;Power on EGSE;1;;;;
147:20;WIND;Start wind weighting analysis;;1;;;;
147:20;EGSE;Check CLD connection;;1;;;;
@ -373,7 +373,8 @@ vers.;v4.26;Launch Procedure;;0;MRL;MCC;RdHill;Time per step
0:00;MCC;BEGIN SEQUENCE: PASSIVATION (PHASE YELLOW);Passivation;2;;;;
68:40;MCC;Announce BEGIN of Radio Silence;;2;;;;
0:00;MCC;Turn audio volume up;;2;;;;
0:00;MRL;Go to MRL, Close N2O Bottle 1 & N2O Bottle 2, THEN...;;2;;;;
0:00;MRL;Go to MRL, THEN...;;2;;;;
0:00;MRL;Close N2O Bottle 1 & N2O Bottle 2, THEN...;;2;;;;
0:00;MRL;RETURN to Block House;;2;;;;
0:00;EGSE;Open OxDV;;2;;;;
0:00;EGSE;Open OxV1;;2;;;;

Can't render this file because it contains an unexpected character in line 155 and column 11.

View File

@ -1,4 +1,4 @@
vers.;v4.26;Passivation out of sequence Procedure;;2;mrl;mcc;rdh;time
vers.;v4.27;Passivation out of sequence Procedure;;2;mrl;mcc;rdh;time
0:00;MCC;BEGIN SEQUENCE: Prepare Passivation Sequence;Prepare Passivation;2;;;;
0:00;MCC/MRL;Recall and make sure BOTH N2O Bottles & He Bottle 2 are still closed! Else continue with Abort Procedure;;2;;;;
0:00;MCC;Inform OPS of Passivation out of sequence;;2;;;;

1 vers. v4.26 v4.27 Passivation out of sequence Procedure 2 mrl mcc rdh time
2 0:00 MCC BEGIN SEQUENCE: Prepare Passivation Sequence Prepare Passivation 2
3 0:00 MCC/MRL Recall and make sure BOTH N2O Bottles & He Bottle 2 are still closed! Else continue with Abort Procedure 2
4 0:00 MCC Inform OPS of Passivation out of sequence 2