procedure/AbortProcedure.csv

3.4 KiB

1vers.v4.27Abort Procedure3mrlmccrdhtime
20:00MCCBEGIN SEQUENCE: Defueling RocketDefueling3
30:00MCCInform OPS of Launch Abort3
40:00EGSEConfirm all valve switches are in OFF position (Except OxDV & HPDV)3
50:00OBDHConfirm all valve switches are in OFF position (Except RMOxSV)3
60:00OBDHActivate Heizi3
70:00MCCTurn audio volume up3
80:00EGSEOpen & Close OxDV STEPWISE until OxOutPT 0 Bar3
90:00EGSEOpen OxDV3
100:00EGSEOpen MPV33
110:00EGSEConfirm OxOutPT 0 bar3
120:00EGSEClose MPV33
130:00EGSEClose OxDV3
140:00EGSEOpen HPDV3
150:00EGSEConfirm HPLPT 0 bar3
160:00EGSEClose HPDV3
170:00OBDHConfirm ROxTPT & RHPPT 1 Bar, if more: Open & Close stepwise RDV3
180:00OBDHDeactivate Heizi3
190:00ALLWait for Launchpad to be clear of N2O fumes depending on OxMass before Defueling3
200:00MCCBEGIN SEQUENCE: Ground support equipment passivationGSE Passivation3
210:00EGSETurn ON EPS_BAT (Rocket OFF)2
220:00MCCAnnounce BEGIN of Radio Silence3
230:00MRLGo to MRL, THEN...2
240:00MRLRemove HP section maintenance cover, THEN...2
250:00MRLOpen RMDV & Step Back, Wait until NCE-Tank is pressureless, THEN...2
260:00MRLClose N2O Bottle 1 & N2O Bottle 2, THEN...2
270:00MRLRETURN to Block House2
280:00EGSEOpen OxDV2
290:00EGSEOpen OxV12
300:00EGSEConfirm OxInPT1 & OxOutPT 0 Bar2
310:00EGSEClose OxV12
320:00EGSEOpen OxV22
330:00EGSEConfirm OxInPT2 & OxOutPT 0 Bar2
340:00EGSEClose OxV22
350:00EGSEClose OxDV 2
360:00MRLGo to MRL, confirm OxInPG1 & OxInPG2 0 Bar, else RETURN to Block House, THEN...2
370:00MRLClose He Bottle 2, THEN...2
380:00MRLWrite down remaining Pressure of He Bottle 2, THEN...2
390:00MRLReturn to Block House2
400:00EGSEOpen HPDV2
410:00EGSEOpen HPV22
420:00EGSEConfirm pressure HPLPT & HPPT2 0 Bar2
430:00EGSEClose HPV22
440:00EGSEClose HPDV2
450:00MRLGo to Testrig, confirm HPPG2 0 Bar, else return to Block House, THEN...2
460:00MRLClose He Bottle 1, THEN ...2
470:00MRLOpen ComTerm2
488:15MCCTurn ON ComTerm step delay2
490:00MCC/MRLWrite down remaining Pressure of He Bottle 12
500:00MRLStep back2
510:00EGSEOpen HPDV2
520:00EGSEOpen HPV12
530:00EGSEConfirm pressure HPLPT & HPPT1 0 Bar2
540:00EGSEClose HPV12
550:00EGSEClose HPDV2
560:00EGSEPressure Check2
570:00MRLOpen MBV2
580:00EGSE/ MRLCheck and compare pressure HPPT1 with HPPG12
590:00MRLClose MBV2
600:00MRLTake out Bridges B1 & B2 from EGSE2
610:00MRLDisconnect Ignition Umbilical200:30
620:00MRLSafety is ensured2
630:00MCCConfirm to OPS that Safety is ensured1
640:00MCCBEGIN SEQUENCE: Data collectionData collection1
650:00AVCTurn off GoPro & Camcorder & Stop Block House Video recording1
660:00EGSECopy PID.vi.tdms & save to new name1
670:00EGSEWait for buffer storage process to be finished1
680:00EGSEsave data files from cRio to PC1
690:00WINDSave data on external HDD1
700:00TMTCStop TMTC Vi and save data on external HDD1
710:00AVCEnd audio recording1
720:00MCCStop ComTerm and save logfile to external HDD, THEN...1
730:00MCCRestart ComTerm VI1
740:00AVCSave video & audio data on external HDD1
750:00MCCEND OF PROCEDUREEND1