1vers.v4.32Abort Procedure3mrlmccrdhtime
20:00MCCBEGIN SEQUENCE: Prepare Launch AbortPrepare Launch Abort3
30:00MCCInform OPS of Launch Abort3
40:00EGSEConfirm all valve switches are in OFF position (Except OxDV & HPDV)3
50:00OBDHConfirm all valve switches are in OFF position (Except RMOxSV)3
60:00MCCTurn audio volume up3
70:00MCCBEGIN SEQUENCE: Defueling RocketDefueling3
80:00OBDHActivate Heizi3
90:00EGSEOpen & Close OxDV STEPWISE until OxOutPT 0 Bar3
100:00EGSEOpen OxDV3
110:00EGSEOpen MPV33
120:00EGSEConfirm OxOutPT 0 bar3
130:00EGSEClose MPV33
140:00EGSEClose OxDV3
150:00EGSEOpen HPDV3
160:00EGSEConfirm HPLPT 0 bar3
170:00EGSEClose HPDV3
180:00OBDHConfirm ROxTPT & RHPPT 1 Bar, if more: Open & Close stepwise RDV3
190:00OBDHDeactivate Heizi3
200:00ALLWait for Launchpad to be clear of N2O fumes depending on OxMass before Defueling3
210:00MCCBEGIN SEQUENCE: Ground support equipment passivationGSE Passivation3
220:00EGSETurn ON EPS_BAT (Rocket OFF)2
230:00MCCAnnounce BEGIN of Radio Silence3
240:00MRLGo to MRL, THEN...2
250:00MRLClose N2O Bottle 1 & N2O Bottle 2, THEN...2
260:00MRLRETURN to Block House2
270:00EGSEOpen OxDV2
280:00EGSEOpen OxV12
290:00EGSEConfirm OxInPT1 & OxOutPT 0 Bar2
300:00EGSEClose OxV12
310:00EGSEOpen OxV22
320:00EGSEConfirm OxInPT2 & OxOutPT 0 Bar2
330:00EGSEClose OxV22
340:00EGSEClose OxDV 2
350:00MRLGo to MRL, confirm OxInPG1 & OxInPG2 0 Bar, else RETURN to Block House, THEN...2
360:00MRLClose He Bottle 2, THEN...2
370:00MRLWrite down remaining Pressure of He Bottle 2, THEN...2
380:00MRLReturn to Block House2
390:00EGSEOpen HPDV2
400:00EGSEOpen HPV22
410:00EGSEConfirm pressure HPLPT & HPPT2 0 Bar2
420:00EGSEClose HPV22
430:00EGSEClose HPDV2
440:00MCCLower MRL to 0 degrees205:00
450:00MRLGo to Testrig, confirm HPPG2 0 Bar, else return to Block House, THEN...2
460:00MRLRemove HP section maintenance cover, THEN...2
470:00MRLOpen RMDV & Step Back, Wait until NCE-Tank is pressureless, THEN...2
480:00MRLClose He Bottle 1, THEN ...2
490:00MRLOpen ComTerm2
508:15MCCTurn ON ComTerm step delay2
510:00MCC/MRLWrite down remaining Pressure of He Bottle 12
520:00MRLStep back2
530:00EGSEOpen HPDV2
540:00EGSEOpen HPV12
550:00EGSEConfirm pressure HPLPT & HPPT1 0 Bar2
560:00EGSEClose HPV12
570:00EGSEClose HPDV2
580:00EGSEPressure Check2
590:00MRLOpen MBV2
600:00EGSE/ MRLCheck and compare pressure HPPT1 with HPPG12
610:00MRLClose MBV2
620:00MRLTake out Bridges B1 & B2 from EGSE2
630:00MRLDisconnect Ignition Umbilical200:30
640:00MRLSafety is ensured2
650:00MCCConfirm to OPS that Safety is ensured1
660:00MCCBEGIN SEQUENCE: Data collectionData collection1
670:00AVCTurn off GoPro & Camcorder & Stop Block House Video recording1
680:00EGSECopy PID.vi.tdms & save to new name1
690:00EGSEWait for buffer storage process to be finished1
700:00EGSEsave data files from cRio to PC1
710:00WINDSave data on external HDD1
720:00TMTCStop TMTC Vi and save data on external HDD1
730:00AVCEnd audio recording1
740:00MCCStop ComTerm and save logfile to external HDD, THEN...1
750:00MCCRestart ComTerm VI1
760:00AVCSave video & audio data on external HDD1
770:00MCCEND OF PROCEDUREEND1