procedure/AbortProcedure.csv

3.2 KiB

1vers.v4.18Abort Procedure3
20:00MCCInform OPS of Launch Abort3
30:00MCCBEGIN:Defueling RocketDefueling3
40:00EGSEConfirm all valve switches are in OFF position (Except OxDV & HPDV)3
50:00OBDHConfirm all valve switches are in OFF position (Except RMOxSV)3
60:00OBDHActivate Heizi3
70:00MCCTurn audio volume up2
80:00EGSEOpen & Close OxDV STEPWISE until OxOutPT 0 Bar3
90:00EGSEOpen OxDV3
100:00EGSEOpen MPV33
110:00EGSEConfirm OxOutPT 0 bar3
120:00EGSEClose MPV33
130:00EGSEClose OxDV3
140:00EGSEOpen HPDV3
150:00EGSEConfirm HPLPT 0 bar3
160:00EGSEClose HPDV3
170:00OBDHConfirm ROxTPT & RHPPT 1 Bar, if more: Open & Close stepwise RDV3
180:00OBDHDeactivate Heizi3
190:00ALLWait for Launchpad to be clear of N2O fumes depending on OxMass before Defueling3
200:00MCCBEGIN: ground segment passivationGSE Passivation3
210:00MCCAnnounce BEGIN of Radio Silence3
220:00MRLGo to MRL, Close N2O Bottle 1 & N2O Bottle 2, THEN...2
230:00MRLRETURN to Block House2
240:00EGSEOpen OxDV2
250:00EGSEOpen OxV12
260:00EGSEConfirm OxInPT1 & OxOutPT 0 Bar2
270:00EGSEClose OxV12
280:00EGSEOpen OxV22
290:00EGSEConfirm OxInPT2 & OxOutPT 0 Bar2
300:00EGSEClose OxV22
310:00EGSEClose OxDV 2
320:00MRLClose He Bottle 2, THEN...2
330:00MRLWrite down remaining Pressure of He Bottle 2, THEN...2
340:00MRLReturn to Block House2
350:00EGSEOpen HPDV2
360:00EGSEOpen HPV22
370:00EGSEConfirm pressure HPLPT & HPPT2 0 Bar2
380:00EGSEClose HPV22
390:00EGSEClose HPDV2
400:00MRLGo to Testrig, confirm HPPG2 0 Bar, else return to Block House, THEN...2
410:00MRLClose He Bottle 1, THEN ...2
420:00MRLOpen ComTerm2
438:15MCCTurn ON ComTerm step delay3
440:00MCC/MRLWrite down remaining Pressure of He Bottle 12
450:00MRLStep back2
460:00EGSEOpen HPDV2
470:00EGSEOpen HPV12
480:00EGSEConfirm pressure HPLPT & HPPT1 0 Bar2
490:00EGSEClose HPV12
500:00EGSEClose HPDV2
510:00EGSEPressure Check2
520:00MRLOpen MBV2
530:00EGSE/ MRLCheck and compare pressure HPPT1 with HPPG12
540:00MRLClose MBV2
550:00MRLTake out Bridges B1 & B2 from EGSE2
560:00MRLDisconnect Ignition Umbilical100:30
570:00MRLSafety is ensured2
580:00MCCConfirm to OPS that Safety is ensured1
590:00MCCBEGIN SEQUENCE: Data collectionData collection1
600:00AVCTurn off GoPro & Camcorder & Stop Block House Video recording1
610:00EGSECopy PID.vi.tdms & save to new name1
620:00EGSEWait for buffer storage process to be finished1
630:00EGSEsave data files from cRio to PC1
640:00WINDSave data on external HDD1
650:00TMTCStop TMTC Vi and save data on external HDD1
660:00AVCEnd audio recording1
670:00MCCStop ComTerm and save logfile to external HDD, THEN...1
680:00MCCRestart ComTerm VI1
690:00AVCSave video & audio data on external HDD1
700:00MCCEND OF PROCEDURE1