procedure/PassivationProcedure.csv

2.1 KiB

1vers.v4.18Passivation out of sequence Procedure2
20:00MCC/MRLRecall and make sure N2O Bottles are still closed! Else continue with Abort Procedure2
30:00MCCInform OPS of Passivation out of sequence2
40:00MRLStep Back/Leave MRL2
50:00EGSEConfirm all valve switches are in OFF position (Except OxDV & HPDV)2
60:00OBDHConfirm all valve switches are in OFF position (Except RMOxSV)2
70:00EGSEOpen & Close OxDV STEPWISE until OxOutPT 0 Bar2
80:00EGSEOpen OxDV2
90:00EGSEOpen MPV32
100:00EGSEConfirm OxOutPT 0 bar2
110:00EGSEClose MPV32
120:00EGSEOpen OxV12
130:00EGSEConfirm OxInPT1 & OxOutPT 0 Bar2
140:00EGSEClose OxV12
150:00EGSEOpen OxV22
160:00EGSEConfirm OxInPT2 & OxOutPT 0 Bar2
170:00EGSEClose OxV22
180:00EGSEClose OxDV 2
190:00EGSEOpen HPDV2
200:00EGSEConfirm HPLPT 0 bar2
210:00EGSEOpen HPV22
220:00EGSEConfirm HPLPT 0 bar2
230:00EGSEClose HPDV2
240:00MCCBEGIN:Passivation of RocketPassivation of Rocket2
250:00OBDHOpen & Close stepwise RDV until RHPPT & ROxTPT 1 Bar2
260:00OBDHConfirm RHPPT & ROxTPT 1 Bar2
270:00MRLGo to MRL2
280:00MRLRemove HP section maintenance cover2
290:00MRLOpen RMDV & Step Back, Wait until NCE-Tank is pressureless2
300:00MCCBEGIN:Passivation of GSEPassivation of GSE2
310:00MRLClose He Bottle 12
320:00MCC/MRLWrite down remaining Pressure of He Bottle 12
330:00MRLStep back2
340:00EGSEOpen HPDV2
350:00EGSEOpen HPV12
360:00EGSEConfirm pressure HPLPT & HPPT1 0 Bar2
370:00EGSEClose HPV12
380:00EGSEClose HPDV2
390:00EGSEPressure Check2
400:00MRLOpen MBV2
410:00EGSE/ MRLCheck and compare pressure HPPT1 with HPPG12
420:00MRLClose MBV2
430:00MRLSafety is ensured2
440:00MCCConfirm to OPS that Safety is ensured1
450:00MCCEND OF PROCEDURE1