procedure/LaunchProcedure.csv

22 KiB
Raw Blame History

1vers.v4.8Launch Procedure0MRLMCCRdHillTime per step
2147:20MCCBEGIN SEQUENCE: Power on EGSEPower on EGSE1
3147:20EGSECheck CLD connection1
4147:20EGSESwitch ON CLD via Battery & check voltage (24 Volt)1
5147:20EGSESwitch ON the primary and secondary supply switches on the Control Panel101:00
6146:20EGSE@MRLSwitch ON Sup_24V_20A & check voltage (ca. 27,2 Volt)1
7146:20EGSE@MRLSwitch ON Sup_24V_10A & check voltage (ca. 27,2 Volt)1
8146:20EGSE@MRLSwitch ON Sup_12V_10A & check voltage (ca. 13,8 Volt)1
9146:20EGSE@MRLSwitch ON Bat_24V_20A & check voltage (ca. 27,9 Volt)1
10146:20EGSE@MRLSwitch ON Bat_24V_10A & check voltage (ca. 27,9 Volt)1
11146:20EGSE@MRLSwitch ON Bat_12V_10A & check voltage (ca. 13,8 Volt)1
12146:20EGSE@MRLSwitch ON Sup_24V_40A1
13146:20EGSE@MRLSwitch ON Sup_5V_10A103:00
14143:20EGSEConnect to cRio1
15130:40EGSEConfirm storage capacity of cRio is greater than [!!!]100:10
16143:20EGSEStart RT_VI1
17143:20EGSEOpen PID-VI and confirm it is running1
18143:20EGSERename PID-Logfile102:00
19141:20MCCBEGIN SEQUENCE: Connect Data UmbilicalConnect Data Umbilical100:30
20141:20MRLConfirm working personel is grounded1
21141:20EGSL@MRLConfirm ALL 8 Grounding bridges are inserted1
22141:20EGSL@MRLConnect Data Umbilical1
23140:50EGSETurn on EPS_BAT1
24140:50EGSETurn on EPS_EXT1
25140:50EGSE@MRLLeave EPS_BAT inserted and remove the other 7 Grounding Bridges1
26140:50EGSE@MRLInsert EPS_EXT Fuse in Power Supply Control Panel1
27140:50EGSE@MRLConfirm green LED at EPS_EXT Fuse is on1
28140:50EGSE@MRLInsert Main_Bus Fuse in Power Supply Control Panel1
29140:50EGSE@MRLConfirm LED at Main_Bus Fuse is OFF. Else Pull fuse and insert all Grounding Bridges1
30140:50EGSE@MRLSet remaining Fuses (except Payload Fuse) and check for green LED1
31140:50EGSETurn OFF EPS_BAT1
32140:50EGSE@MRLConfirm Main bus LED is on.1
33140:50EGSEStart EPS via EPS_ext1
34140:50OBDHClear SD-Card-using FileZilla FTP101:00
35139:50OBDHConnect to sbRio1
36139:50OBDHStart RT_Main1
37139:50MRLConfirm 3 beeps at OBC11
38139:50OBDHOpen RT_Sub_HMI1
39139:50OBDHConfirm Main Chute button is disabled1
40139:50EGSE@MRLInsert Payload Fuse1
41139:50EGSE@MRLConfirm green LED at Payload Fuse is on1
42139:50MCCBEGIN SEQUENCE: Connect Fueling armConnect Fueling Arm1
43139:50MRLConfirm working personel is grounded101:00
44139:50MRLConfirm PPG 0 bar1
45138:50MRLRemove Pneumatic Line from Fueling arm1
46138:50MRLMove Fueling arm to rocket1
47138:50MRLCouple Helium coupling1
48138:50MRLCouple N2O coupling1
49138:50MRLReattach Pneumatic Line to Fueling arm103:00
50135:50EGSEBEGIN SEQUENCE: EGSE Valve and Actuator checkEGSE Valve & Actuator Check1
51135:50MCCConfirm that video recording is enabled @ MCC100:10
52135:50MRLConfirm that Ignition Umbilical is disconnected1
53135:40OBDHCheck EPS hardware Voltages100:10
54135:30EGSEStart PID data recording100:10
55135:20MRLClose HPNV100:10
56135:10EGSE/MRLSwitch OxDV to closed & check if magnetic valve LED is on100:10
57135:00EGSE/MRLSwitch HPDV to closed & check if magnetic valve LED is on100:10
58134:50EGSE/MRLCheck warning lamp on HPSM100:10
59134:40MRLRemove loose equipment103:00
60131:40EGSEActivate Heizi100:10
61131:30EGSEActivate N2O_Heater 1100:10
62131:20EGSEActivate N2O_Heater 2100:10
63131:10EGSEActivate He_Heater100:10
64131:00OBDHVerify Heizi @ RDVT & RDVET100:10
65130:50EGSE/MRLCheck Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD100:10
66130:40EGSE/MRLCheck Water Temperatures @ OxWT1, OxWT2, HPWT2100:10
67130:30EGSEDeactivate Heizi100:10
68130:20EGSECheck OxV1 (CLD & RT_VI)100:10
69130:10EGSECheck OxV2 (CLD & RT_VI)100:10
70130:00EGSECheck MPV3 (CLD & RT_VI)100:10
71129:50EGSECheck HPV1 (CLD & RT_VI)100:10
72129:40EGSECheck HPV2 (CLD & RT_VI)100:10
73129:30EGSECheck MPV1/2 (CLD & RT_VI)100:10
74129:20EGSECheck RDV (CLD & RT_VI)100:10
75129:10EGSECheck RMOxOV (CLD & RT_VI)100:10
76129:00EGSECheck RMOxSV (CLD & RT_VI)100:10
77128:50OBDHActivate Heizi100:10
78128:40OBDHVerify Heizi @ RDVT & RDVET101:00
79127:40OBDHCheck RDV100:10
80127:30OBDHCheck RNCEV100:10
81127:20OBDHCheck RMOxOV100:10
82127:10OBDHCheck RMOxSV100:10
83127:00OBDHConfirm RNCEV is disabled100:10
84125:00MRLConfirm MBV closed1
85125:00EGSEConfirm that all valve switches are in OFF position (Except OxDV & HPDV)10:10
86115:00MRL/EGSECheck loadcell by applying force to it100:20
87114:40OBDHCheck RHPPT shows atmosphere1
88114:40OBDHCheck ROxTPT shows atmosphere1
89114:40OBDHCheck RIHPT shows atmosphere1
90114:40OBDHCheck RCCPT shows atmosphere1
91114:40OBDHCheck RBaro1 shows atmosphere1
92114:40OBDHCheck RBaro2 shows atmosphere1
93114:40EGSECheck HPPT1 shows 0 bar100:20
94114:20EGSECheck HPPT2 shows 0 bar1
95114:20EGSECheck HPLPT shows 0 bar1
96114:20EGSECheck OxInPT1 shows 0 bar1
97114:20EGSECheck OxInPT2 shows 0 bar1
98114:20EGSECheck OxOutPT shows 0 bar100:20
99114:00EGSE/MRLSwitch on N2O coupling & check if magnetic valve LED is on1
100114:00EGSE/MRLSwitch on He coupling & check if magnetic valve LED is on1
101114:00EGSE/MRLSwitch on swivle arm & check if magnetic valve LED is on1
102114:00EGSESwitch off swivel arm & He coupling & N2O coupling101:00
103114:00MCCBEGIN SEQUENCE: Ignition signal TestIgnition signal Test101:00
104113:00MRLConfirm that Ignition Umbilical is disconnected1
105113:00MRLConnect Ignition test receptical1
106113:00EGSE@MRLPlug in Bridges B1 and B21
107113:00MRLConfirm Soundsignal from Ignition Umbilical1
108113:00EGSETurn on Ignition Secure Switch1
109113:00EGSE/OBDHTurn on Ignition Switch for 2 Second & Confirm ignition signal received at sbRio & cRio1
110113:00EGSEConfirm that Ignition Switch is switched OFF and secured1
111113:00EGSETurn off Ignition Secure Switch1
112113:00EGSE@MRLRemove Bridges B1 and B21
113113:00MRLRemove Ignition test receptical103:00
114110:00MCCBEGIN SEQUENCE: Ground segment pressure test (PHASE YELLOW) GSE Pressure Test1
115130:50EGSE/MRLCheck Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD100:10
116130:40EGSE/MRLCheck Water Temperatures @ OxWT1, OxWT2, HPWT2100:10
117110:00MRLConfirm that all hatches are closed101:00
118109:00MRLCheck He bottle 1 connector is attached1
119109:00MRLCheck He bottle 2 connector is attached1
120109:00MRLCheck N2O bottle 1 connector is attached1
121109:00MRLCheck N2O bottle 2 connector is attached1
122109:00MRLCheck hose between HPSM & N2OSM is connected on both ends1
123109:00MRLCheck hose between HPSM & Flight Segment is connected on both ends1
124109:00MRLCheck hose between N2OSM & Flight Segment is connected on both ends1
125109:00MRLCheck Pneumatik hose is connected on both ends102:00
126107:00MRLPut on safety equipment2
127107:00MRLConfirm MBV is closed2
128107:00MRLConfirm HPNV is closed2
129107:00MRLMove into Position to open He Bottle 12
130107:00EGSEConfirm if HPV1 is closed2
131107:00EGSEConfirm MPV1/2 is closed2
132107:00MRLOpen He Bottle 1201:00
133106:00MRLCheck & compare pressure HPPT1 with HPPG1 (max 300 bar)2
134106:00MRLCheck Gastech Silver HPPR1 (max 300 to 50 bar)2
135106:00MRLCheck Harris PPR (50 to 8 bar)2
136106:00MRLCheck pneumatic PPG (8 bar)2
137106:00MRLStep back201:00
138105:00EGSE/MRLOpen & Close HPV1 SHORTLY & Check HPPT12
139105:00EGSECheck HPPT1 300 Bar2
140105:00EGSEConfirm HPLPT 0 Bar2
141105:00EGSE/MRLOpen & Close HPV2 SHORTLY & Check HPPT2 0 bar2
142105:00EGSE/MRLOpen & Close HPDV SHORTLY & Check HPLPT 0 bar2
143105:00EGSE/MRLOpen & Close OxV1 SHORTLY2
144105:00EGSE/MRLOpen & Close OxV2 SHORTLY2
145105:00EGSE/MRLOpen & Close OxDV SHORTLY2
146105:00EGSE/MRLOpen & Close MPV3 SHORTLY2
147105:00EGSECheck HPLPT & OxOutPT 0 Bar201:30
148103:30EGSEDecouple N2O coupling2
149103:30EGSEDecouple Helium coupling200:20
150103:10EGSEMove arm away from rocket2
151103:10EGSEMove arm to rocket201:00
152102:10MRLClose He Bottle 1 and check HPSM for leakage (If leakage occurs continue with Passivation Procedure)201:00
153101:10MRLOpen MBV2
154101:10EGSE/MRLCheck and compare pressure HPPT1 with HPPG1 0 Bar2
155101:10MRLClose MBV200:30
156100:40MRLSafety is ensured2
157100:40MCCEGSE@MRL to MRL1
158100:40EGSESwitch OFF N20 coupling1
159100:40EGSESwitch OFF He coupling1
160100:40MRLConfirm working personel is grounded101:00
161100:40MRLRelease Pneumatic lines of couplings100:20
162100:20EGSEConfirm Fueling arm is switched OFF1
163100:20EGSECheck OxOutPT and HPLPT 0 bar1
164100:20MRLCouple He coupling100:30
16599:50MRLCouple N2O coupling100:30
16699:50MRLConfirm He coupling is connected properly1
16799:50MRLConfirm N2O coupling is connected properly1
168130:50EGSE/MRLCheck Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD100:10
169130:40EGSE/MRLCheck Water Temperatures @ OxWT1, OxWT2, HPWT2100:10
17099:20MRLHOLDHOLD1
17199:20MCCCONTINUE AFTER HOLD
172130:50EGSE/MRLCheck Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD100:10
173130:40EGSE/MRLCheck Water Temperatures @ OxWT1, OxWT2, HPWT2100:10
17499:20MRLBEGIN SEQUENCE: Prime RocketPrime Rocket1
17599:20EGSETurn ON EPS_BAT101:00
17699:20MRLConfirm working personel is grounded101:00
17799:20MRLConfirm all spring retracted hatches are moving freely1
17898:50MRLTurn on GoPro Camera at end of Launch Rail100:20
17999:20MRLConnect Ignition Umbilical100:30
18098:30MRLInsert all EPS Bridges103:00
18195:30MRLConfirm Bridge Hatch is Secured100:20
18295:10EGSE@MRLreturn to MCC1
18395:10OPSElevate MRL to 90 degrees105:00
18489:40EGSECalibrate loadcell (Set to 0)101:00
18588:40MCCBEGIN SEQUENCE: Fueling Preparations (PHASE YELLOW)Fueling Preparations2
186130:50EGSE/MRLCheck Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD100:10
187130:40EGSE/MRLCheck Water Temperatures @ OxWT1, OxWT2, HPWT2100:10
18888:40MRLPut on safety equipment200:30
18910:10MRLOpen HPNV 1/8 Rev2
19088:10MRLOpen He Bottle 1201:00
19187:10MRLStep back2
19287:10EGSEOpen & Close STEPWISE MPV1/MPV2 to 50 Bar @ OxInPT1 & OxInPT22
19387:10EGSE/MRLCheck & compare OxInPT1 with OxInPG1 based on Bottle temperature (max 50 bar)2
19487:10EGSE/MRLCheck & compare pressure OxInPT2 with OxInPG2 based on Bottle temperature (max 50 bar)2
19587:10EGSE/MRLCheck Temperature of N2O Bottle 1 @OxT1 & OxWT1 (max 22C)2
19687:10EGSE/MRLCheck Temperature of N2O Bottle 2 @OxT2 & OxWT2 (max 22C)201:30
19785:40MRLOpen He Bottle 22
19885:40EGSE/MRLCheck & compare pressure HPPT2 with HPPG2 (max 315 bar)201:00
19984:40ALL/MRLCAUTION!2
20084:40MRLOpen N2O Bottle 12
20184:40MRL/EGSECheck & compare pressure OxInPT 1 with OxInPG 1 (max 50 bar)202:00
20282:40MRLOpen N2O Bottle 22
20382:40MRL/EGSECheck & compare pressure OxInPT 2 with OxInPG 2 (max 50 bar)202:00
20480:40MRLInsert Ignition Bridges B1 and B2 into EGSE202:00
20578:40MRLConfirm Soundsignal from Ignition Umbilical2
20678:40MRLClose ComTerm & Go to Block House2
20778:40MCCTurn OFF MRL confirm lock2
20878:40ALLInform OPS to clear Launch Pad (Tel.: [!!!])22:00
209130:50EGSE/MRLCheck Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD100:10
210130:40EGSE/MRLCheck Water Temperatures @ OxWT1, OxWT2, HPWT2100:10
21168:40MCCHOLDHOLD2
21268:40KLPStart Camera Karsten Lapp<70>hn2
21368:40MCCCONTINUE AFTER HOLD2
214130:50EGSE/MRLCheck Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD100:10
215130:40EGSE/MRLCheck Water Temperatures @ OxWT1, OxWT2, HPWT2100:10
216130:40EGSEConfirm storage capacity of CRio is greater than [!!!]100:10
21768:40MCCBEGIN SEQUENCE Ox Fueling (PHASE RED)Ox Fueling (PHASE RED)3
21868:40MCCAnnounce end of Radio Silence3
21968:40EGSETurn OFF EPS_BAT3
220126:50OBDH/TMTCCheck RF451-Link100:20
221126:30TMTCConfirm GPS-lock100:20
222126:10TMTCConfirm Telemega-Link100:20
223125:50OBDHTest Connection to STX3100:20
224125:30OBDHConfirm that STX3 Package received by email100:30
225125:30AVCTurn on main TMTC screen100:30
226125:30MCCRequest Permission to begin fueling from OPS103:00
22768:40OBDHAcknowledge start of Fueling301:00
22867:40EGSEOpen & Close HPV1 STEPWISE to 50 Bar @ ROxTPT (stop every 10 bar & check ROxTBT & ROxTTT (approx. ambiente temp)3
22967:40EGSEConfirm OxOutPT 0 Bar to check ROxCV tightness3
23067:40EGSEOpen & Close HPV1 STEPWISE to more than 50 Bar @ RHPPT and confirm ROxTPT 50 Bar3
23167:40EGSEConfirm HPV1 is closed3
23267:40OBDHOpen RDV SHORTLY, to check tightness @ RHPPT & ROxTPT (If leakages occur continue with Abort Procedure)3
23367:40EGSEOpen MPV1/MPV23
23467:40EGSEOpen & Close MPV3 STEPWISE to 50 Bar @ OxOutPT3
23567:40EGSEClose MPV1/MPV23
23667:40EGSECheck & compare OxOutPT with OxInPT13
23767:40EGSECheck if RHPPT & ROxTPT more than OxInPT1, If less Open & Close HPV13
23867:40EGSEZero OxTank Mass3
23967:40MCCWrite down Time3
24067:40EGSEOpen OxV1304:00
24163:40OBDHOpen & Close RDV STEPWISE until N2O bottle empty or 25kg OxTankMass, keep temperatures RDVT and RDVET above 10<31>C and Check delta ROxTPT and OxInPT1330:00
24233:40EGSEVerify Bottle Temperatures @ OxT1, OxT2, HPT2100:10
24333:40EGSEVerify Water Temperatures @ Ox@T1, OxWT2, HPWT2100:10
24433:40EGSEClose OxV1300:10
24533:30EGSECheck if Pressure rises in OxPT1, if Pressure rises relief via OxV1 or wait for Pressure relief valve301:00
24632:30EGSECheck & compare OxOutPT with OxInPT23
24732:30EGSECheck & compare RHPPT & ROxTPT 50 Bar and more than OxInPT2, If less Open & Close HPV13
24832:30EGSEOpen OxV2 3
24932:30OBDHOpen & Close RDV STEPWISE to 25kg OxTankMass, keep temperatures RDVT and RDVET above 10<31>C and Check delta OxTPT and OxInPT1320:00
25012:30EGSEClose OxV2 300:10
25112:20EGSECheck if Pressure rises in OxPT2, if Pressure rises relief via OxV2 or wait for Pressure relief valve301:00
25211:20EGSEOpen OxDV STEPWISE until OxOutPT 0 Bar3
25311:20OBDHCheck ROxCV for tightness @ ROxTPT3
25411:20EGSEClose OxDV301:00
25510:20EGSEWrite down OxTankMass3
25633:40EGSEVerify He Bottle 2 Temperature @HPT2 & @HPWT2 (turn ON He_Heater if necessary) 100:10
25710:20MCCProvide OxTankMass and temperature readings to Wind weighting station300:30
2589:50EGSEConfirm OxV1 & OxV2 closed3
2599:50EGSECheck OxOutPT 0 Bar3
2609:50EGSEDecouple N2O coupling300:20
2619:30MCCConfirm End of Oxidator Fueling to OPS300:15
2629:15OBDH/TMTCCheck RF451-Link300:20
2638:55TMTCCheck GPS-lock300:20
2648:35TMTCCheck Telemega-Link300:20
26533:40EGSEVerify He Bottle 2 Temperature @HPT2 & @HPWT2 (turn ON/OFF He_Heater if necessary) 100:10
2668:15MCCHOLD (Last possible scheduled HOLD)HOLD3
2678:15OPSAlign MRL to Launch Trajectory3
2688:15MCCTurn audio volume down3
2698:15MCCTurn OFF ComTerm step delay3
2708:15ALLTalk through Ignition Sequence3
2718:15MCCWait for OPS to confirm final MRL adjustment3
2728:15AVCStart Video recording in Block House3
2738:15MCCCONTINUE AFTER HOLD
2748:15EGSEVerify He Bottle 2 Temperature @HPT2 & @HPWT2 (turn ON/OFF He_Heater if necessary) 100:10
2758:15MCCBEGIN SEQUENCE: Switching to Internal Power SequenceSwitch to Internal Power3
2768:15EGSETurn OFF EPS_Ext (Switch to internal Power)300:20
2777:55OBDHConfirm EPS Voltages are within limits300:10
2787:45OBDHConfirm RF451 Transmitting300:05
2797:40OBDH/TMTCConfirm RF451-Link300:20
2807:20TMTCConfirm GPS-lock300:20
2817:00TMTCConfirm Telemega-Link300:20
2826:40OBDHSwitch to PREARMED300:10
2836:30PYLConfirm Payload is running300:20
2846:30PYLConfirm BlackBox2 is ready for launch3
2856:10AVCConfirm that videorecording @ MCC is running300:05
2866:05MCCBEGIN SEQUENCE: High Pressure FuelingHigh Pressure Fueling3
28733:40EGSEVerify He Bottle 2 Temperature @HPT2 & @HPWT2 (turn ON/OFF He_Heater if necessary) 100:10
2886:05EGSEOpen & Close HPV1 STEPWISE until RHPPT 300 Bar or pressure equal to He Bottle 13
2896:05EGSEOpen & Close HPV2 STEPWISE until RHPPT 300 Bar 3
2906:05EGSEOpen & close HPDV STEPWISE until HPLPT 0 Bar 3
2916:05EGSEConfirm HPDV closed3
2926:05OBDH/EGSECheck for leakage & HPLPT 0 Bar & RHPPT 300 Bar 302:00
2936:05EGSETurn OFF He_Heater3
2944:05OBDHAcknowledge end of Fueling300:10
2953:55MCCConfirm End of Fueling to OPS300:20
2963:35MCCBEGIN SEQUENCE: Disconnecting Fueling ArmDisconnecting Fueling Arm300:10
2973:25EGSEConfirm HPV1 & HPV2 closed300:10
2983:15EGSECheck HPLPT 0 Bar 300:10
2993:05EGSEDecouple Helium coupling300:20
3002:45EGSEConfirm Helium coupling is disconnected300:10
3012:35EGSEMove fueling arm away from rocket300:40
3021:55MCCConfirm Fueling Arm away to OPS300:15
3031:40MCCPrepare for Launch300:10
3041:30OBDHConfirm ready for launch300:10
3051:20EGSEConfirm ready for launch300:10
3061:10MCCSet Go/No-Go System to Go300:10
3071:00MCCWait for Authorization for Launch300:00
3081:00MCCBEGIN SEQUENCE: IgnitionIgnition Sequence400:10
3090:50OBDHT-50 ARM400:05
3100:40OBDHT-40 Confirm all status indicators green400:05
3110:30OBDHT-30 Disconnect from sbRio400:30
3120:10EGSET-10 Turn on Ignition Secure400:07
3130:03EGSET-3: Ignition400:03
3140:00OBDHT+0: Verify RMOxOV Open (Launched)400:00
3150:00EGSET+1: Turn OFF Ignition4
3160:00EGSET+5: Turn OFF Ignition Secure4
3170:00OBDHT+20: Verify RMOxOV Closed and RMOxSV Open (Cruise)4
3180:00OBDHT+50: Verify RNCEV Open (Drogue)4
3190:00OBDHT+310: Verify Main Chute Deployed and RDV Open (Main)4
3200:00OBDHT+600: Verify (Landed)4
3210:00MCCBEGIN SEQUENCE: PASSIVATION (PHASE YELLOW) (Write down Time)Passivation2
32268:40MCCAnnounce BEGIN of Radio Silence3
3230:00MCCTurn audio volume up2
3240:00MRLGo to MRL, Close N2O Bottle 1 & N2O Bottle 2, THEN... RETURN to Block House2
3250:00MRLRETURN to Block House2
3260:00EGSEOpen OxDV2
3270:00EGSEOpen OxV12
3280:00EGSECheck OxInPT1 & OxOutPT 0 Bar2
3290:00EGSEClose OxV12
3300:00EGSEOpen OxV22
3310:00EGSECheck OxInPT2 & OxOutPT 0 Bar2
3320:00EGSEClose OxV22
3330:00EGSEClose OxDV 2
3340:00MRLClose He Bottle 2, THEN...2
3350:00MRLWrite down remaining Pressure of He Bottle 2, THEN...2
3360:00MRLReturn to Block House2
3370:00EGSEOpen HPDV2
3380:00EGSEOpen HPV22
3390:00EGSECheck pressure HPLPT & HPPT2 0 Bar2
3400:00EGSEClose HPV22
3410:00EGSEClose HPDV2
3420:00MRLGo to Testrig, confirm HPPG2 0 Bar, else return to Block House, THEN...2
3430:00MRLClose He Bottle 1, THEN ...2
3440:00MRLOpen ComTerm2
3450:00MCCTurn on MRL lock2
3460:00MRLWrite down remaining Pressure of He Bottle 12
3470:00MRLStep back2
3480:00EGSEOpen HPDV2
3490:00EGSEOpen HPV12
3500:00EGSECheck pressure HPLPT & HPPT1 0 Bar2
3510:00EGSEClose HPV12
3520:00EGSEClose HPDV2
3530:00EGSEPressure Check2
3540:00MRLOpen MBV2
3550:00EGSE/MRLCheck and compare pressure HPPT1 with HPPG12
3560:00MRLClose MBV2
3570:00MRLTake out B1 & B2 Bridges2
3580:00MRLSafety is ensured2
3590:00MCCConfirm to OPS that Safety is ensured1
3600:00MCCBEGIN SEQUENCE: Data collectionData collection1
3610:00AVCTurn off GoPro & Camcorder & Stop Block House Video recording1
3620:00EGSECopy PID.vi.tdms & save to new name1
3630:00EGSEWait for buffer storage process to be finished1
3640:00EGSEsave data files from cRio to PC1
3650:00WINDSave data on external HDD1
3660:00TMTCStop TMTC Vi and save data on external HDD1
3670:00AVCEnd audio recording1
3680:00MCCStop ComTerm and save logfile to external HDD, THEN...1
3690:00MCCRestart ComTerm VI1
3700:00AVCSave video & audio data on external HDD1
3710:00MCCEND OF PROCEDURE1