1 | vers. | v4.30 | Launch Procedure | 0 | MRL | MCC | RdHill | Time per step | |
---|---|---|---|---|---|---|---|---|---|
2 | 147:20 | MCC | BEGIN SEQUENCE: Power on EGSE | Power on EGSE | 1 | ||||
3 | 147:20 | WIND | Start wind weighting analysis | 1 | |||||
4 | 147:20 | EGSE | Check CLD connection | 1 | |||||
5 | 147:20 | EGSE | Switch ON CLD via Battery & check voltage (24 Volt) | 1 | |||||
6 | 147:20 | EGSE | Switch ON the primary and secondary supply switches on the Control Panel | 1 | 01:00 | ||||
7 | 146:20 | EGSE @MRL | Switch ON Sup_24V_20A & check voltage (ca. 27,2 Volt) | 1 | |||||
8 | 146:20 | EGSE @MRL | Switch ON Sup_24V_10A & check voltage (ca. 27,2 Volt) | 1 | |||||
9 | 146:20 | EGSE @MRL | Switch ON Sup_12V_10A & check voltage (ca. 13,8 Volt) | 1 | |||||
10 | 146:20 | EGSE @MRL | Switch ON Bat_24V_20A & check voltage (ca. 27,9 Volt) | 1 | |||||
11 | 146:20 | EGSE @MRL | Switch ON Bat_24V_10A & check voltage (ca. 27,9 Volt) | 1 | |||||
12 | 146:20 | EGSE @MRL | Switch ON Bat_12V_10A & check voltage (ca. 13,8 Volt) | 1 | |||||
13 | 146:20 | EGSE @MRL | Switch ON Sup_24V_40A | 1 | |||||
14 | 146:20 | EGSE @MRL | Switch ON Sup_5V_10A | 1 | 03:00 | ||||
15 | 143:20 | EGSE | Connect to cRio | 1 | |||||
16 | 130:40 | EGSE | Confirm storage capacity of cRio is greater than 300MB | 1 | 00:10 | ||||
17 | 143:20 | EGSE | Start RT_VI | 1 | |||||
18 | 143:20 | EGSE | Open PID-VI and confirm it is running | 1 | |||||
19 | 143:20 | EGSE | Rename PID-Logfile | 1 | 02:00 | ||||
20 | 141:20 | MCC | BEGIN SEQUENCE: Connect Data Umbilical | Connect Data Umbilical | 1 | 00:30 | |||
21 | 141:20 | MRL | Confirm working personel is grounded | 1 | |||||
22 | 141:20 | EGSE @MRL | Confirm ALL 8 bridges on the right side are inserted | 1 | |||||
23 | 141:20 | EGSE @MRL | Confirm ALL 8 bridges on the left side are removed | 1 | |||||
24 | 141:20 | EGSE @MRL | Connect Data Umbilical | 1 | |||||
25 | 0:00 | EGSE @MRL | Remove EXT_24V GROUND Bridge (1R) | 1 | |||||
26 | 0:00 | EGSE @MRL | Remove MAIN_BUS GROUND Bridge (2R) | 1 | |||||
27 | 0:00 | EGSE @MRL | Remove OBC2_BAT GROUND Bridge (4R) | 1 | |||||
28 | 0:00 | EGSE @MRL | Remove PAYLOAD1 GROUND Bridge (5R) | 1 | |||||
29 | 0:00 | EGSE @MRL | Remove RECOVERY_BAT GROUND Bridge (7R) | 1 | |||||
30 | 140:50 | EGSE | Turn ON EPS_BAT | 1 | |||||
31 | 140:50 | EGSE | Turn ON EPS_EXT_24V | 1 | |||||
32 | 0:00 | EGSE @MRL | Insert EXT_24V Bridge (1L) | 1 | |||||
33 | 0:00 | EGSE @MRL | Confirm EXT_24V LED is ON | 1 | |||||
34 | 0:00 | EGSE @MRL | Insert MAIN_BUS Bridge (2L) | 1 | |||||
35 | 0:00 | EGSE @MRL | Confirm MAIN_BUS LED is OFF (if ON pull MAIN_BUS Bridge (2L) & Insert all grounding Bridges on the right side | 1 | |||||
36 | 0:00 | EGSE @MRL | Remove EPS RADIO SILENCE Bridge (3R) | 1 | |||||
37 | 0:00 | EGSE | Turn OFF EGSE EPS_BAT | 1 | |||||
38 | 0:00 | EGSE @MRL | Confirm MAIN_BUS LED is ON | 1 | |||||
39 | 0:00 | EGSE @MRL | Confirm 1 beep at Telemega | 1 | |||||
40 | 140:50 | OBDH | Clear SD-Card-using FileZilla FTP | 1 | 01:00 | ||||
41 | 139:50 | OBDH | Connect to sbRio using remote Access utility | 1 | |||||
42 | 139:50 | MRL | Confirm 3 beeps at OBC1 | 1 | |||||
43 | 139:50 | OBDH | Open RT_Sub_HMI | 1 | |||||
44 | 139:50 | OBDH | Confirm Main Chute button is disabled | 1 | |||||
45 | 135:40 | OBDH | Check EPS hardware Voltages | 1 | 00:10 | ||||
46 | 0:00 | EGSE | Check EGSE Currents | 1 | 00:10 | ||||
47 | 139:50 | WIND | Report on weather situation | 1 | |||||
48 | 139:50 | MCC | BEGIN SEQUENCE: Connect Fueling arm | Connect Fueling Arm | 1 | ||||
49 | 139:50 | MRL | Confirm working personel is grounded | 1 | 01:00 | ||||
50 | 139:50 | MRL | Confirm PPG 0 bar | 1 | |||||
51 | 138:50 | MRL | Remove Pneumatic Line from Fueling arm | 1 | |||||
52 | 138:50 | MRL | Move Fueling arm to rocket | 1 | |||||
53 | 138:50 | MRL | Couple Helium coupling | 1 | |||||
54 | 138:50 | MRL | Couple N2O coupling | 1 | |||||
55 | 138:50 | MRL | Reattach Pneumatic Line to Fueling arm | 1 | 03:00 | ||||
56 | 135:50 | EGSE | BEGIN SEQUENCE: EGSE sensor and actuator test | EGSE sensor & actuator test | 1 | ||||
57 | 135:50 | MCC | Confirm that video recording is enabled @ MCC | 1 | 00:10 | ||||
58 | 135:50 | MRL | Confirm that Ignition Umbilical is disconnected | 1 | |||||
59 | 135:30 | EGSE | Start PID data recording | 1 | 00:10 | ||||
60 | 135:20 | MRL | Close HPNV1 | 1 | 00:10 | ||||
61 | 135:20 | MRL | Close HPNV2 | 1 | 00:10 | ||||
62 | 135:10 | EGSE/ MRL | Switch OxDV to closed & check if magnetic valve LED is on | 1 | 00:10 | ||||
63 | 135:00 | EGSE/ MRL | Switch HPDV to closed & check if magnetic valve LED is on | 1 | 00:10 | ||||
64 | 134:50 | EGSE/ MRL | Check warning lamp on HPSM | 1 | 00:10 | ||||
65 | 134:40 | MRL | Remove loose equipment | 1 | 03:00 | ||||
66 | 131:40 | EGSE | Activate Heizi | 1 | 00:10 | ||||
67 | 131:30 | EGSE | Activate N2O_Heater 1 | 1 | 00:10 | ||||
68 | 131:20 | EGSE | Activate N2O_Heater 2 | 1 | 00:10 | ||||
69 | 131:10 | EGSE | Activate He_Heater | 1 | 00:10 | ||||
70 | 131:00 | OBDH | Verify Heizi @ RDVT & RDVET | 1 | 00:10 | ||||
71 | 130:50 | EGSE/ MRL | Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD | 1 | 00:10 | ||||
72 | 130:40 | EGSE/ MRL | Check Water Temperatures @ OxWT1, OxWT2, HPWT2 | 1 | 00:10 | ||||
73 | 130:30 | EGSE | Deactivate Heizi | 1 | 00:10 | ||||
74 | 130:20 | EGSE/ MRL | Check OxV1 (CLD & RT_VI) | 1 | 00:10 | ||||
75 | 130:10 | EGSE/ MRL | Check OxV2 (CLD & RT_VI) | 1 | 00:10 | ||||
76 | 130:00 | EGSE/ MRL | Check MPV3 (CLD & RT_VI) | 1 | 00:10 | ||||
77 | 129:50 | EGSE/ MRL | Check HPV1 (CLD & RT_VI) | 1 | 00:10 | ||||
78 | 129:40 | EGSE/ MRL | Check HPV2 (CLD & RT_VI) | 1 | 00:10 | ||||
79 | 129:30 | EGSE/ MRL | Check MPV1/2 (CLD & RT_VI) | 1 | 00:10 | ||||
80 | 129:20 | EGSE/ MRL | Check RDV (CLD & RT_VI) | 1 | 00:10 | ||||
81 | 129:10 | EGSE/ MRL | Check RMOxOV (CLD & RT_VI) | 1 | 00:10 | ||||
82 | 129:00 | EGSE/ MRL | Check RMOxSV (CLD & RT_VI) | 1 | 00:10 | ||||
83 | 128:50 | OBDH | Activate Heizi | 1 | 00:10 | ||||
84 | 128:40 | OBDH | Verify Heizi @ RDVT & RDVET | 1 | 01:00 | ||||
85 | 127:40 | OBDH/ MRL | Check RDV | 1 | 00:10 | ||||
86 | 127:30 | OBDH/ MRL | Check RNCEV | 1 | 00:10 | ||||
87 | 127:20 | OBDH/ MRL | Check RMOxOV | 1 | 00:10 | ||||
88 | 127:10 | OBDH/ MRL | Check RMOxSV | 1 | 00:10 | ||||
89 | 127:00 | OBDH/ MRL | Disable RNCEV | 1 | 00:10 | ||||
90 | 125:00 | MRL | Confirm MBV closed | 1 | |||||
91 | 125:00 | EGSE | Confirm that all valve switches are in OFF position (Except OxDV & HPDV) | 1 | 00:10 | ||||
92 | 115:00 | MRL/ EGSE | Check loadcell by applying force to it | 1 | 00:20 | ||||
93 | 114:40 | OBDH | Check RHPPT shows atmosphere | 1 | |||||
94 | 114:40 | OBDH | Check ROxTPT shows atmosphere | 1 | |||||
95 | 114:40 | OBDH | Check RIHPT shows atmosphere | 1 | |||||
96 | 114:40 | OBDH | Check RCCPT shows atmosphere | 1 | |||||
97 | 114:40 | OBDH | Check RBaro1 shows atmosphere | 1 | |||||
98 | 114:40 | OBDH | Check RBaro2 shows atmosphere | 1 | |||||
99 | 114:40 | EGSE | Check HPPT1 shows 0 bar | 1 | 00:20 | ||||
100 | 114:20 | EGSE | Check HPPT2 shows 0 bar | 1 | |||||
101 | 114:20 | EGSE | Check HPLPT shows 0 bar | 1 | |||||
102 | 114:20 | EGSE | Check OxInPT1 shows 0 bar | 1 | |||||
103 | 114:20 | EGSE | Check OxInPT2 shows 0 bar | 1 | |||||
104 | 114:20 | EGSE | Check OxOutPT shows 0 bar | 1 | 00:20 | ||||
105 | 114:00 | EGSE/ MRL | Switch on N2O coupling & check if magnetic valve LED is on | 1 | |||||
106 | 114:00 | EGSE/ MRL | Switch on He coupling & check if magnetic valve LED is on | 1 | |||||
107 | 114:00 | EGSE/ MRL | Switch on swivle arm & check if magnetic valve LED is on | 1 | |||||
108 | 114:00 | EGSE | Switch off swivel arm & He coupling & N2O coupling | 1 | 01:00 | ||||
109 | 114:00 | MCC | BEGIN SEQUENCE: Ignition signal Test | Ignition signal Test | 1 | 01:00 | |||
110 | 113:00 | MRL | Confirm that Ignition Umbilical is disconnected | 1 | |||||
111 | 113:00 | MRL | Connect Ignition test receptical | 1 | |||||
112 | 113:00 | EGSE @MRL | Plug in Bridges B1 and B2 | 1 | |||||
113 | 113:00 | MRL | Confirm Soundsignal from Ignition Umbilical | 1 | |||||
114 | 113:00 | EGSE | Turn on Ignition Secure Switch | 1 | |||||
115 | 113:00 | EGSE/ OBDH | Turn on Ignition Switch for 2 Second & Confirm ignition signal received at sbRio & cRio | 1 | |||||
116 | 113:00 | EGSE | Confirm that Ignition Switch is switched OFF and secured | 1 | |||||
117 | 113:00 | EGSE | Turn off Ignition Secure Switch | 1 | |||||
118 | 113:00 | EGSE @MRL | Remove Bridges B1 and B2 | 1 | |||||
119 | 113:00 | MRL | Remove Ignition test receptical | 1 | 03:00 | ||||
120 | 113:00 | MRL | Remove Ignition test receptical | 1 | 03:00 | ||||
121 | 110:00 | MCC | BEGIN SEQUENCE: Ground segment pressure test (PHASE YELLOW) | GSE Pressure Test | 2 | LuF, AlS, LeD: 1x Helm, 3x Ear protectors | ChB, FiH, JuL, LiA, MiS | ||
122 | 130:50 | EGSE/ MRL | Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD | 2 | 00:10 | ||||
123 | 130:40 | EGSE/ MRL | Check Water Temperatures @ OxWT1, OxWT2, HPWT2 | 2 | 00:10 | ||||
124 | 109:00 | MRL | Confirm He bottle 1 connector is attached | 2 | |||||
125 | 109:00 | MRL | Confirm He bottle 2 connector is attached | 2 | |||||
126 | 109:00 | MRL | Confirm N2O bottle 1 connector is attached | 2 | |||||
127 | 109:00 | MRL | Confirm N2O bottle 2 connector is attached | 2 | |||||
128 | 109:00 | MRL | Confirm hose between HPSM & N2OSM is connected on both ends | 2 | |||||
129 | 109:00 | MRL | Confirm hose between HPSM & Flight Segment is connected on both ends | 2 | |||||
130 | 109:00 | MRL | Confirm hose between N2OSM & Flight Segment is connected on both ends | 2 | |||||
131 | 109:00 | MRL | Confirm pneumatic hose is connected on both ends | 2 | 02:00 | ||||
132 | 107:00 | MRL | Put on safety equipment | 2 | |||||
133 | 107:00 | MRL | Confirm MBV is closed | 2 | |||||
134 | 107:00 | MRL | Confirm HPNV1 is closed | 2 | |||||
135 | 107:00 | MRL | Confirm HPNV2 is closed | 2 | |||||
136 | 107:00 | MRL | Take positions to open He Bottle 1 | 2 | |||||
137 | 107:00 | EGSE | Confirm HPV1 is closed | 2 | |||||
138 | 107:00 | EGSE | Confirm MPV1/2 is closed | 2 | |||||
139 | 107:00 | MRL | Open He Bottle 1 | 2 | 01:00 | ||||
140 | 106:00 | MRL | Check & compare pressure HPPT1 with HPPG1 (max 300 bar) | 2 | |||||
141 | 106:00 | MRL | Check Gastech Silver HPPR1 (max 300 to 50 bar) | 2 | |||||
142 | 106:00 | MRL | Check Harris PPR (50 to 8 bar) | 2 | |||||
143 | 106:00 | MRL | Check pneumatic PPG (8 bar) | 2 | |||||
144 | 106:00 | MRL | Step back | 2 | 01:00 | ||||
145 | 105:00 | EGSE/ MRL | Open & Close HPV1 SHORTLY & Check HPPT1 | 2 | |||||
146 | 105:00 | EGSE | Check HPPT1 300 Bar | 2 | |||||
147 | 105:00 | EGSE | Confirm HPLPT 0 Bar | 2 | |||||
148 | 105:00 | EGSE/ MRL | Open & Close HPV2 SHORTLY & Confirm HPPT2 0 bar | 2 | |||||
149 | 105:00 | EGSE/ MRL | Open & Close HPDV SHORTLY & Confirm HPLPT 0 bar | 2 | |||||
150 | 105:00 | EGSE/ MRL | Open & Close OxV1 SHORTLY | 2 | |||||
151 | 105:00 | EGSE/ MRL | Open & Close OxV2 SHORTLY | 2 | |||||
152 | 105:00 | EGSE/ MRL | Open & Close OxDV SHORTLY | 2 | |||||
153 | 105:00 | EGSE/ MRL | Open & Close MPV3 SHORTLY | 2 | |||||
154 | 0:00 | MRL | Open HPNV1 completely | 2 | |||||
155 | 0:00 | MRL | Step Back | 2 | |||||
156 | 0:00 | EGSE | Open & Close HPV1 STEPWISE untile HPLPT equal to HPPT1 and check for leakage @HPLPT (If leakage occurs proceed to passivation Procedure out of sequence) | 2 | |||||
157 | 0:00 | EGSE | Close HPV1 | 2 | |||||
158 | 0:00 | EGSE | Open HPDV & confirm HPLPT 0 Bar | 2 | |||||
159 | 0:00 | EGSE | Open HPV2 & confirm HPPT2 0 Bar | 2 | |||||
160 | 0:00 | EGSE | Close HPV2 | 2 | |||||
161 | 0:00 | EGSE | Close HPDV | 2 | |||||
162 | 87:10 | EGSE | Open & Close STEPWISE MPV1/2 to 50 Bar @ OxInPT1 & OxInPT2 | 2 | |||||
163 | 87:10 | EGSE | Confirm MPV1/2 closed | 2 | |||||
164 | 87:10 | EGSE | Open OxDV | 2 | |||||
165 | 87:10 | EGSE | Open & Close STEPWISE MPV3 to 0 Bar @OxOutPT | 2 | |||||
166 | 87:10 | EGSE | Check OxInPT1 and OxInPT2 for leakage (If leakage occurs proceed to passivation Procedure out of sequence) | 2 | |||||
167 | 87:10 | EGSE | Confirm MPV3 closed | 2 | |||||
168 | 87:10 | EGSE | Open & Close STEPWISE OxV1 to 0 Bar @OxInPT1 | 2 | |||||
169 | 87:10 | EGSE | Open & Close STEPWISE OxV2 to 0 Bar @OxInPT2 | 2 | |||||
170 | 87:10 | EGSE | Confirm OxOutPT 0 Bar | 2 | |||||
171 | 87:10 | EGSE | Close OxDV | 2 | |||||
172 | 105:00 | EGSE | Confirm HPLPT & OxOutPT 0 Bar | 2 | 01:30 | ||||
173 | 103:30 | EGSE | Decouple N2O coupling | 2 | |||||
174 | 103:30 | EGSE | Decouple Helium coupling | 2 | 00:20 | ||||
175 | 103:10 | EGSE | Move arm away from rocket | 2 | |||||
176 | 103:10 | EGSE | Move arm to rocket | 2 | 01:00 | ||||
177 | 102:10 | MRL | Close He Bottle 1 and check HPSM for leakage (If leakage occurs proceed to passivation Procedure out of sequence) | 2 | 01:00 | ||||
178 | 101:10 | MRL | Open MBV | 2 | |||||
179 | 101:10 | EGSE/ MRL | Check and compare pressure HPPT1 with HPPG1 0 Bar | 2 | |||||
180 | 101:10 | MRL | Close MBV | 2 | 00:30 | ||||
181 | 100:40 | MRL | Safety is ensured | 2 | |||||
182 | 100:40 | MCC | EGSE @MRL to MRL | 1 | |||||
183 | 100:40 | EGSE | Switch OFF N20 coupling | 1 | |||||
184 | 100:40 | EGSE | Switch OFF He coupling | 1 | |||||
185 | 100:40 | MRL | Confirm working personel is grounded | 1 | 01:00 | ||||
186 | 100:40 | MRL | Confirm PPG 0 Bar | 1 | 00:20 | ||||
187 | 100:40 | MRL | Release Pneumatic lines of couplings | 1 | 00:20 | ||||
188 | 100:20 | EGSE | Confirm Fueling arm is switched OFF | 1 | |||||
189 | 100:20 | EGSE | Confirm OxOutPT and HPLPT 0 bar | 1 | |||||
190 | 100:20 | MRL | Couple He coupling | 1 | 00:30 | ||||
191 | 99:50 | MRL | Couple N2O coupling | 1 | 00:30 | ||||
192 | 99:50 | MRL | Confirm He coupling is connected properly | 1 | |||||
193 | 99:50 | MRL | Confirm N2O coupling is connected properly | 1 | |||||
194 | 130:50 | EGSE/ MRL | Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD | 1 | 00:10 | ||||
195 | 130:40 | EGSE/ MRL | Check Water Temperatures @ OxWT1, OxWT2, HPWT2 | 1 | 00:10 | ||||
196 | 99:20 | MRL | HOLD | HOLD | 1 | ||||
197 | 99:20 | MCC | CONTINUE AFTER HOLD | 1 | |||||
198 | 99:20 | MRL | BEGIN SEQUENCE: On Board System Test | On Board System Test | 2 | ||||
199 | 130:50 | EGSE/ MRL | Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD | 1 | 00:10 | ||||
200 | 130:40 | EGSE/ MRL | Check Water Temperatures @ OxWT1, OxWT2, HPWT2 | 1 | 00:10 | ||||
201 | 99:40 | OBDH | Check RDV | 2 | 00:10 | ||||
202 | 99:30 | OBDH | Check RNCEV | 2 | 00:10 | ||||
203 | 99:20 | OBDH | Check RMOxOV | 2 | 00:10 | ||||
204 | 99:10 | OBDH | Check RMOxSV | 2 | 00:10 | ||||
205 | 99:00 | OBDH | Disable RNCEV | 2 | 00:10 | ||||
206 | 0:00 | MRL | Confirm working personel is grounded | 2 | 01:00 | ||||
207 | 0:00 | OBDH | Disconnect from sbRio | 1 | |||||
208 | 0:00 | EGSE | Turn ON EPS_BAT (Rocket OFF) | 2 | 01:00 | ||||
209 | 0:00 | EGSE @MRL | Insert EPS RADIO SILENCE Bridge (3R) | 1 | |||||
210 | 0:00 | EGSE @MRL | Insert MAIN_BAT Bridge (3L) | 1 | |||||
211 | 0:00 | EGSE @MRL | Confirm MAIN_BAT LED is ON | 1 | |||||
212 | 0:00 | EGSE @MRL | Insert OBC2_BAT Bridge (4L) | 1 | |||||
213 | 0:00 | EGSE @MRL | Confirm OBC2_BAT LED is ON | 1 | |||||
214 | 0:00 | EGSE @MRL | Insert RECOVERY_BAT Bridge (7L) | 1 | |||||
215 | 0:00 | EGSE @MRL | Confirm RECOVERY_BAT LED is ON | 1 | |||||
216 | 0:00 | EGSE @MRL | Insert PAYLOAD1 Bridge (5L) | 1 | |||||
217 | 0:00 | EGSE @MRL | Confirm PAYLOAD1 LED is OFF | 1 | |||||
218 | 0:00 | EGSE @MRL | Insert PAYLOAD2 Bridge (6L) | 1 | |||||
219 | 0:00 | EGSE @MRL | Confirm PAYLOAD2 LED is ON | 1 | |||||
220 | 0:00 | EGSE @MRL | Confirm MAIN_BUS LED is OFF | 1 | |||||
221 | 0:00 | EGSE @MRL | Remove EPS RADIO SILENCE Bridge (3R) | 1 | |||||
222 | 0:00 | EGSE | Turn OFF EPS_BAT (Rocket ON) | 2 | 01:00 | ||||
223 | 0:00 | EGSE @MRL | Confirm MAIN_BUS LED is ON | 1 | |||||
224 | 0:00 | EGSE @MRL | Confirm 1 beep at Telemega | 1 | |||||
225 | 0:00 | EGSE @MRL | Remove BLACKBOX2 RADIO SILENCE Bridge (3R) | 1 | |||||
226 | 139:50 | OBDH | Connect to sbRio using remote Access utility | 1 | |||||
227 | 139:50 | MRL | Confirm 3 beeps at OBC1 | 1 | |||||
228 | 139:50 | OBDH | Open RT_Sub_HMI | 1 | |||||
229 | 139:50 | OBDH | Confirm Main Chute button is disabled | 1 | |||||
230 | 135:40 | OBDH | Check EPS hardware Voltages | 1 | 00:10 | ||||
231 | 0:00 | EGSE | Check EGSE Currents | 1 | 00:10 | ||||
232 | 125:30 | PYL | Confirm CanSat is running | 3 | 00:20 | ||||
233 | 125:30 | PYL | Confirm BlackBox2 is running | 3 | |||||
234 | 125:30 | EGSE | Turn OFF EPS_EXT_24V | 3 | |||||
235 | 125:30 | PYL | Confirm CanSat is running | 3 | 00:20 | ||||
236 | 125:30 | PYL | Confirm BlackBox2 is running | 3 | |||||
237 | 125:30 | EGSE | Turn ON EPS_EXT_24V | 3 | |||||
238 | 0:00 | OBDH | Disconnect from sbRio | 1 | |||||
239 | 99:20 | EGSE | Turn ON EPS_BAT (Rocket OFF) | 2 | 01:00 | ||||
240 | 99:20 | MRL | BEGIN SEQUENCE: Prime Rocket | Prime Rocket | 2 | ||||
241 | 99:20 | EGSE | Confirm EPS_BAT is ON (Rocket OFF) | 2 | 01:00 | ||||
242 | 99:20 | MRL | Confirm working personel is grounded | 2 | 01:00 | ||||
243 | 99:20 | MRL | Confirm that RMDV is closed | 2 | 01:00 | ||||
244 | 99:00 | MRL | Close & secure HP maintenance cover | 2 | 01:00 | ||||
245 | 99:00 | MRL | Close & secure MainOX maintenance cover | 2 | 01:00 | ||||
246 | 98:50 | MRL | Turn on GoPro Camera at end of Launch Rail | 2 | 00:20 | ||||
247 | 141:20 | EGSE @MRL | Confirm ALL 8 bridges on the right side are removed | 1 | |||||
248 | 141:20 | EGSE @MRL | Confirm ALL 8 bridges on the left side are inserted | 1 | |||||
249 | 95:30 | MRL | Close & secure bridge maintenance cover | 2 | 00:20 | ||||
250 | 99:20 | MRL | Confirm spring retracted cover at He coupling is moving freely | 2 | |||||
251 | 99:20 | MRL | Confirm spring retracted cover at N2O coupling is moving freely | 2 | |||||
252 | 95:00 | MRL | Confirm that HP maintenance cover is closed & secured | 2 | 01:00 | ||||
253 | 95:30 | MRL | Confirm bridge maintenance cover is closed & secured | 2 | 00:20 | ||||
254 | 95:00 | MRL | Confirm that MainOX maintenance cover is closed & secured | 2 | 01:00 | ||||
255 | 95:10 | EGSE @MRL | Leave MRL & return to MCC | 2 | |||||
256 | 99:20 | MRL | Connect Ignition Umbilical | 2 | 00:30 | ||||
257 | 95:10 | OPS | Elevate MRL to 90 degrees | 2 | 05:00 | ||||
258 | 89:40 | EGSE | Zero OxTank Mass | 2 | 01:00 | ||||
259 | 88:40 | MCC | BEGIN SEQUENCE: Fueling Preparations (PHASE YELLOW) | Fueling Preparations | 2 | ||||
260 | 130:50 | EGSE/ MRL | Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD | 2 | 00:10 | ||||
261 | 130:40 | EGSE/ MRL | Check Water Temperatures @ OxWT1, OxWT2, HPWT2 | 2 | 00:10 | ||||
262 | 88:40 | MRL | Put on safety equipment | 2 | 00:30 | ||||
263 | 10:10 | MRL | Confirm HPNV1 is Open | 2 | |||||
264 | 10:10 | MRL | Confirm HPNV2 is Closed | 2 | |||||
265 | 88:10 | MRL | Open He Bottle 1 | 2 | 01:00 | ||||
266 | 87:10 | MRL | Step back | 2 | |||||
267 | 0:00 | EGSE | Open & Close HPV1 STEPWISE untile HPLPT equal to HPPT1 and check for leakage @HPLPT (If leakage occurs continue with "GSE Passivation Procedure") | 2 | |||||
268 | 0:00 | EGSE | Open HPV1 | 2 | |||||
269 | 0:00 | EGSE | Open & Close HPV2 STEPWISE untile HPPT2 equal to HPLPT and check for leakage @HPPT2 (If leakage occurs continue with "GSE Passivation Procedure") | 2 | |||||
270 | 0:00 | EGSE | Close HPV1 | 2 | |||||
271 | 0:00 | EGSE | Open HPDV & Confirm HPLPT 0 Bar | 2 | |||||
272 | 0:00 | EGSE | Confirm HPV1 is closed | 2 | |||||
273 | 0:00 | EGSE | Confirm HPV2 is closed | 2 | |||||
274 | 10:10 | MRL | Open HPNV2 1/8 Rev | 2 | |||||
275 | 0:00 | EGSE | Close HPDV | 2 | |||||
276 | 87:10 | EGSE | Open & Close STEPWISE MPV1/2 to 50 Bar @ OxInPT1 & OxInPT2 | 2 | |||||
277 | 87:10 | EGSE/ MRL | Check & compare OxInPT1 with OxInPG1 based on Bottle temperature (max 50 bar) | 2 | |||||
278 | 87:10 | EGSE/ MRL | Check & compare pressure OxInPT2 with OxInPG2 based on Bottle temperature (max 50 bar) | 2 | |||||
279 | 87:10 | EGSE/ MRL | Check Temperature of N2O Bottle 1 @OxT1 & OxWT1 (max 22C) | 2 | |||||
280 | 87:10 | EGSE/ MRL | Check Temperature of N2O Bottle 2 @OxT2 & OxWT2 (max 22C) | 2 | 01:30 | ||||
281 | 85:40 | MRL | Open He Bottle 2 | 2 | |||||
282 | 85:40 | EGSE/ MRL | Check & compare pressure HPPT2 with HPPG2 (max 315 bar) | 2 | 01:00 | ||||
283 | 84:40 | ALL/ MRL | CAUTION! | 2 | |||||
284 | 84:40 | MRL | Open N2O Bottle 1 | 2 | |||||
285 | 84:40 | MRL/ EGSE | Check & compare pressure OxInPT 1 with OxInPG 1 (max 50 bar) | 2 | 02:00 | ||||
286 | 82:40 | MRL | Open N2O Bottle 2 | 2 | |||||
287 | 82:40 | MRL/ EGSE | Check & compare pressure OxInPT 2 with OxInPG 2 (max 50 bar) | 2 | 02:00 | ||||
288 | 80:40 | MRL | Insert Ignition Bridges B1 and B2 into EGSE | 2 | 02:00 | ||||
289 | 78:40 | MRL | Confirm Soundsignal from Ignition Umbilical | 2 | |||||
290 | 78:40 | MRL | Close ComTerm & Go to Block House | 2 | |||||
291 | 78:40 | MCC | Turn OFF MRL confirm lock | 2 | |||||
292 | 78:40 | ALL | Inform OPS to clear Launch Pad (Tel.: [!!!]) | 2 | 02:00 | ||||
293 | 147:20 | WIND | Start wind weighting analysis | 2 | |||||
294 | 130:50 | EGSE/ MRL | Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD | 2 | 00:10 | ||||
295 | 130:40 | EGSE/ MRL | Check Water Temperatures @ OxWT1, OxWT2, HPWT2 | 2 | 00:10 | ||||
296 | 68:40 | MCC | HOLD | HOLD | 2 | ||||
297 | 68:40 | KLP | Start Camera Karsten Lapp<70>hn | 2 | |||||
298 | 68:40 | MCC | CONTINUE AFTER HOLD | 2 | |||||
299 | 130:50 | EGSE/ MRL | Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD | 2 | 00:10 | ||||
300 | 130:40 | EGSE/ MRL | Check Water Temperatures @ OxWT1, OxWT2, HPWT2 | 2 | 00:10 | ||||
301 | 130:40 | EGSE | Confirm storage capacity of CRio is greater than 300MB | 2 | 00:10 | ||||
302 | 127:00 | OBDH | Confirm RNCEV is disabled | 2 | 00:10 | ||||
303 | 68:40 | MCC | BEGIN SEQUENCE Ox Fueling (PHASE RED) | Ox Fueling (PHASE RED) | 3 | ||||
304 | 68:50 | WIND | Report on weather situation | 3 | |||||
305 | 68:40 | MCC | Announce end of Radio Silence | 3 | |||||
306 | 68:40 | EGSE | Turn OFF EPS_BAT (Rocket ON) | 3 | |||||
307 | 0:00 | OBDH | Connect to sbRio using remote Access utility | 1 | |||||
308 | 0:00 | MCC | Confirm 3 beeps at OBC1 | 1 | |||||
309 | 0:00 | OBDH | Open RT_Sub_HMI | 1 | |||||
310 | 0:00 | OBDH | Confirm Main Chute button is disabled | 1 | |||||
311 | 0:00 | OBDH | Check EPS hardware Voltages | 1 | 00:10 | ||||
312 | 0:00 | EGSE | Check EGSE Currents | 1 | 00:10 | ||||
313 | 126:50 | OBDH/ TMTC | Confirm RF451-Link | 3 | 00:20 | ||||
314 | 126:30 | TMTC | Confirm GPS-lock | 3 | 00:20 | ||||
315 | 126:10 | TMTC | Confirm Telemega-Link | 3 | 00:20 | ||||
316 | 125:50 | OBDH | Test Connection to STX3 | 3 | 00:20 | ||||
317 | 125:30 | OBDH | Confirm that STX3 Packages are received by email | 3 | 00:30 | ||||
318 | 125:30 | AVC | Turn on main TMTC screen | 3 | 00:30 | ||||
319 | 125:30 | PYL | Confirm CanSat is running | 3 | 00:20 | ||||
320 | 125:30 | PYL | Confirm BlackBox2 is running | 3 | |||||
321 | 125:30 | MCC | Request Permission to begin fueling from OPS | 3 | 03:00 | ||||
322 | 68:40 | OBDH | Acknowledge start of Fueling | 3 | 01:00 | ||||
323 | 67:40 | EGSE | Open & Close HPV1 STEPWISE to 50 Bar @ ROxTPT (stop every 10 bar & check ROxTBT & ROxTTT (approx. ambiente temp) | 3 | |||||
324 | 67:40 | EGSE | Confirm OxOutPT 0 Bar to check ROxCV tightness | 3 | |||||
325 | 67:40 | EGSE | Open & Close HPV1 STEPWISE to more than 50 Bar @ RHPPT and confirm ROxTPT 50 Bar | 3 | |||||
326 | 67:40 | EGSE | Confirm HPV1 is closed | 3 | |||||
327 | 67:40 | OBDH | Open RDV SHORTLY, to check tightness @ RHPPT & ROxTPT (If leakages occur continue with Abort Procedure) | 3 | |||||
328 | 67:40 | EGSE | Open MPV1/2 | 3 | |||||
329 | 67:40 | EGSE | Open & Close MPV3 STEPWISE to 50 Bar @ OxOutPT | 3 | |||||
330 | 67:40 | EGSE | Close MPV1/2 | 3 | |||||
331 | 67:40 | EGSE | Check & compare OxOutPT with OxInPT1 | 3 | |||||
332 | 67:40 | EGSE | Check if RHPPT & ROxTPT more than OxInPT1, If less Open & Close HPV1 | 3 | |||||
333 | 67:40 | EGSE | Zero OxTank Mass | 3 | |||||
334 | 67:40 | MCC | Write down Time | 3 | |||||
335 | 67:40 | EGSE | Open OxV1 | 3 | 04:00 | ||||
336 | 63:40 | OBDH | Open & Close RDV STEPWISE until N2O bottle empty or 25kg OxTankMass, keep temperatures RDVT and RDVET above 10<31>C and Check delta ROxTPT and OxInPT1 | 3 | 30:00:00 | ||||
337 | 33:40 | EGSE | Verify Bottle Temperatures @ OxT1, OxT2, HPT2 | 3 | 00:10 | ||||
338 | 33:40 | EGSE | Verify Water Temperatures @ Ox@T1, OxWT2, HPWT2 | 3 | 00:10 | ||||
339 | 33:40 | EGSE | Close OxV1 | 3 | 00:10 | ||||
340 | 33:30 | EGSE | Check if Pressure rises in OxPT1, if Pressure rises relief via OxV1 or wait for Pressure relief valve | 3 | 01:00 | ||||
341 | 32:30 | EGSE | Check & compare OxOutPT with OxInPT2 | 3 | |||||
342 | 32:30 | EGSE | Check & compare RHPPT & ROxTPT 50 Bar and more than OxInPT2, If less Open & Close HPV1 | 3 | |||||
343 | 32:30 | EGSE | Open OxV2 | 3 | |||||
344 | 32:30 | OBDH | Open & Close RDV STEPWISE to 25kg OxTankMass, keep temperatures RDVT and RDVET above 10<31>C and Check delta OxTPT and OxInPT1 | 3 | 20:00 | ||||
345 | 12:30 | EGSE | Close OxV2 | 3 | 00:10 | ||||
346 | 12:20 | EGSE | Check if Pressure rises in OxPT2, if Pressure rises relief via OxV2 or wait for Pressure relief valve | 3 | 01:00 | ||||
347 | 11:20 | EGSE | Open OxDV STEPWISE until OxOutPT 0 Bar | 3 | |||||
348 | 11:20 | OBDH | Check ROxCV for tightness @ ROxTPT | 3 | |||||
349 | 11:20 | EGSE | Close OxDV | 3 | 01:00 | ||||
350 | 10:20 | EGSE | Write down OxTankMass | 3 | |||||
351 | 33:40 | EGSE | Verify He Bottle 2 Temperature @HPT2 & @HPWT2 (turn ON He_Heater if necessary) | 3 | 00:10 | ||||
352 | 10:20 | MCC | Provide OxTankMass and temperature readings to Wind weighting station | 3 | 00:30 | ||||
353 | 9:50 | EGSE | Confirm OxV1 & OxV2 closed | 3 | |||||
354 | 9:50 | EGSE | Confirm OxOutPT 0 Bar | 3 | |||||
355 | 9:50 | EGSE | Decouple N2O coupling | 3 | 00:20 | ||||
356 | 9:30 | MCC | Confirm End of Oxidator Fueling to OPS | 3 | 00:15 | ||||
357 | 9:20 | WIND | Start wind weighting analysis | 3 | |||||
358 | 9:15 | OBDH/ TMTC | Check RF451-Link | 3 | 00:20 | ||||
359 | 8:55 | TMTC | Check GPS-lock | 3 | 00:20 | ||||
360 | 8:35 | TMTC | Check Telemega-Link | 3 | 00:20 | ||||
361 | 33:40 | EGSE | Verify He Bottle 2 Temperature @HPT2 & @HPWT2 (turn ON/OFF He_Heater if necessary) | 3 | 00:10 | ||||
362 | 8:15 | MCC | HOLD (Last possible scheduled HOLD) | HOLD | 3 | ||||
363 | 8:15 | OPS | Align MRL to Launch Trajectory | 3 | |||||
364 | 8:15 | MCC | Turn audio volume down | 3 | |||||
365 | 8:15 | MCC | Turn OFF ComTerm step delay | 3 | |||||
366 | 8:15 | ALL | Talk through Ignition Sequence | 3 | |||||
367 | 8:15 | MCC | Wait for OPS to confirm final MRL adjustment | 3 | |||||
368 | 8:15 | WIND | Report on weather situation | 3 | |||||
369 | 8:15 | MCC | CONTINUE AFTER HOLD | 3 | |||||
370 | 8:15 | AVC | Start Video recording in Block House | 3 | |||||
371 | 8:15 | EGSE | Verify He Bottle 2 Temperature @HPT2 & @HPWT2 (turn ON/OFF He_Heater if necessary) | 3 | 00:10 | ||||
372 | 8:15 | MCC | BEGIN SEQUENCE: Switching to Internal Power Sequence | Switch to Internal Power | 3 | ||||
373 | 8:15 | EGSE | Turn OFF EPS_EXT_24V (Switch to internal Power) | 3 | 00:20 | ||||
374 | 7:55 | OBDH | Confirm EPS Voltages are within limits | 3 | 00:10 | ||||
375 | 7:45 | OBDH | Confirm RF451 Transmitting | 3 | 00:05 | ||||
376 | 7:40 | OBDH/ TMTC | Confirm RF451-Link | 3 | 00:20 | ||||
377 | 7:20 | TMTC | Confirm GPS-lock | 3 | 00:20 | ||||
378 | 7:00 | TMTC | Confirm Telemega-Link | 3 | 00:20 | ||||
379 | 6:40 | OBDH | Switch to PREARMED | 3 | 00:10 | ||||
380 | 6:30 | PYL | Confirm Payload is running | 3 | 00:20 | ||||
381 | 6:30 | PYL | Confirm BlackBox2 is ready for launch | 3 | |||||
382 | 6:10 | AVC | Confirm that videorecording @ MCC is running | 3 | 00:05 | ||||
383 | 6:05 | MCC | BEGIN SEQUENCE: High Pressure Fueling | High Pressure Fueling | 3 | ||||
384 | 33:40 | EGSE | Verify He Bottle 2 Temperature @HPT2 & @HPWT2 (turn ON/OFF He_Heater if necessary) | 3 | 00:10 | ||||
385 | 6:05 | EGSE | Open & Close HPV1 STEPWISE until RHPPT 300 Bar or pressure equal to He Bottle 1 | 3 | |||||
386 | 6:05 | EGSE | Open & Close HPV2 STEPWISE until RHPPT 300 Bar | 3 | |||||
387 | 6:05 | EGSE | Open & close HPDV STEPWISE until HPLPT 0 Bar | 3 | |||||
388 | 6:05 | EGSE | Confirm HPDV closed | 3 | |||||
389 | 6:05 | OBDH/ EGSE | Check for leakage & HPLPT 0 Bar & RHPPT 300 Bar | 3 | 02:00 | ||||
390 | 6:05 | EGSE | Turn OFF He_Heater | 3 | |||||
391 | 4:05 | OBDH | Acknowledge end of Fueling | 3 | 00:10 | ||||
392 | 3:55 | MCC | Confirm End of Fueling to OPS | 3 | 00:20 | ||||
393 | 3:35 | MCC | BEGIN SEQUENCE: Disconnecting Fueling Arm | Disconnecting Fueling Arm | 3 | 00:10 | |||
394 | 3:25 | EGSE | Confirm HPV1 & HPV2 closed | 3 | 00:10 | ||||
395 | 3:15 | EGSE | Confirm HPLPT 0 Bar | 3 | 00:10 | ||||
396 | 3:05 | EGSE | Decouple Helium coupling | 3 | 00:20 | ||||
397 | 2:45 | EGSE | Confirm Helium coupling is disconnected | 3 | 00:10 | ||||
398 | 2:35 | EGSE | Move fueling arm away from rocket | 3 | 00:40 | ||||
399 | 1:55 | MCC | Confirm Fueling Arm away to OPS | 3 | 00:15 | ||||
400 | 1:40 | MCC | Prepare for Launch | 3 | 00:10 | ||||
401 | 1:30 | OBDH | Confirm ready for launch | 3 | 00:10 | ||||
402 | 1:20 | EGSE | Confirm ready for launch | 3 | 00:10 | ||||
403 | 1:10 | MCC | Set Go/No-Go System to Go | 3 | 00:10 | ||||
404 | 1:00 | MCC | Wait for Authorization for Launch | 3 | 00:00 | ||||
405 | 1:00 | MCC | BEGIN SEQUENCE: Ignition | Ignition Sequence | 3 | 00:10 | |||
406 | 0:50 | OBDH | T-50 ARM | 3 | 00:05 | ||||
407 | 0:40 | OBDH | T-40 Confirm all status indicators green | 3 | 00:05 | ||||
408 | 0:30 | OBDH | T-30 Disconnect from sbRio | 3 | 00:30 | ||||
409 | 0:10 | EGSE | T-10 Turn on Ignition Secure | 3 | 00:07 | ||||
410 | 0:03 | EGSE | T-3: Ignition | 3 | 00:03 | ||||
411 | 0:00 | OBDH | T+0: Verify RMOxOV Open (Launched) | 3 | 00:00 | ||||
412 | 0:00 | EGSE | T+1: Turn OFF Ignition | 3 | |||||
413 | 0:00 | EGSE | T+5: Turn OFF Ignition Secure | 3 | |||||
414 | 0:00 | OBDH | T+20: Verify RMOxOV Closed and RMOxSV Open (Cruise) | 3 | |||||
415 | 0:00 | OBDH | T+50: Verify RNCEV Open (Drogue) | 3 | |||||
416 | 0:00 | OBDH | T+310: Verify Main Chute Deployed and RDV Open (Main) | 3 | |||||
417 | 0:00 | OBDH | T+600: Verify (Landed) | 3 | |||||
418 | 0:00 | MCC | BEGIN SEQUENCE: PASSIVATION (PHASE YELLOW) | Passivation | 2 | ||||
419 | 68:40 | MCC | Announce BEGIN of Radio Silence | 2 | |||||
420 | 0:00 | MCC | Turn audio volume up | 2 | |||||
421 | 0:00 | MRL | Go to MRL, THEN... | 2 | |||||
422 | 0:00 | MRL | Close N2O Bottle 1 & N2O Bottle 2, THEN... | 2 | |||||
423 | 0:00 | MRL | RETURN to Block House | 2 | |||||
424 | 0:00 | EGSE | Open OxDV | 2 | |||||
425 | 0:00 | EGSE | Open OxV1 | 2 | |||||
426 | 0:00 | EGSE | Confirm OxInPT1 & OxOutPT 0 Bar | 2 | |||||
427 | 0:00 | EGSE | Close OxV1 | 2 | |||||
428 | 0:00 | EGSE | Open OxV2 | 2 | |||||
429 | 0:00 | EGSE | Confirm OxInPT2 & OxOutPT 0 Bar | 2 | |||||
430 | 0:00 | EGSE | Close OxV2 | 2 | |||||
431 | 0:00 | EGSE | Close OxDV | 2 | |||||
432 | 0:00 | MRL | Go to MRL, confirm OxInPG1 & OxInPG2 0 Bar, else RETURN to Block House, THEN... | 2 | |||||
433 | 0:00 | MRL | Close He Bottle 2, THEN... | 2 | |||||
434 | 0:00 | MRL | Write down remaining Pressure of He Bottle 2, THEN... | 2 | |||||
435 | 0:00 | MRL | Return to Block House | 2 | |||||
436 | 0:00 | EGSE | Open HPDV | 2 | |||||
437 | 0:00 | EGSE | Open HPV2 | 2 | |||||
438 | 0:00 | EGSE | Confirm pressure HPLPT & HPPT2 0 Bar | 2 | |||||
439 | 0:00 | EGSE | Close HPV2 | 2 | |||||
440 | 0:00 | EGSE | Close HPDV | 2 | |||||
441 | 0:00 | MRL | Go to Testrig, confirm HPPG2 0 Bar, else return to Block House, THEN... | 2 | |||||
442 | 0:00 | MRL | Close He Bottle 1, THEN ... | 2 | |||||
443 | 0:00 | MRL | Open ComTerm | 2 | |||||
444 | 8:15 | MCC | Turn ON ComTerm step delay | 2 | |||||
445 | 0:00 | MRL | Write down remaining Pressure of He Bottle 1 | 2 | |||||
446 | 0:00 | MRL | Step back | 2 | |||||
447 | 0:00 | EGSE | Open HPDV | 2 | |||||
448 | 0:00 | EGSE | Open HPV1 | 2 | |||||
449 | 0:00 | EGSE | Confirm pressure HPLPT & HPPT1 0 Bar | 2 | |||||
450 | 0:00 | EGSE | Close HPV1 | 2 | |||||
451 | 0:00 | EGSE | Close HPDV | 2 | |||||
452 | 0:00 | EGSE | Pressure Check | 2 | |||||
453 | 0:00 | MRL | Open MBV | 2 | |||||
454 | 0:00 | EGSE/ MRL | Check and compare pressure HPPT1 with HPPG1 | 2 | |||||
455 | 0:00 | MRL | Close MBV | 2 | |||||
456 | 0:00 | MRL | Take out B1 & B2 Bridges | 2 | |||||
457 | 0:00 | MRL | Safety is ensured | 2 | |||||
458 | 0:00 | MCC | Confirm to OPS that Safety is ensured | 2 | |||||
459 | 0:00 | MCC | BEGIN SEQUENCE: Data collection | Data collection | 1 | ||||
460 | 0:00 | AVC | Turn off GoPro & Camcorder & Stop Block House Video recording | 1 | |||||
461 | 0:00 | EGSE | Copy PID.vi.tdms & save to new name | 1 | |||||
462 | 0:00 | EGSE | Wait for buffer storage process to be finished | 1 | |||||
463 | 0:00 | EGSE | save data files from cRio to PC | 1 | |||||
464 | 0:00 | WIND | Save data on external HDD | 1 | |||||
465 | 0:00 | TMTC | Stop TMTC Vi and save data on external HDD | 1 | |||||
466 | 0:00 | AVC | End audio recording | 1 | |||||
467 | 0:00 | MCC | Stop ComTerm and save logfile to external HDD, THEN... | 1 | |||||
468 | 0:00 | MCC | Restart ComTerm VI | 1 | |||||
469 | 0:00 | AVC | Save video & audio data on external HDD | 1 | |||||
470 | 0:00 | MCC | END OF PROCEDURE | End | 1 |