1 | vers. | v4.30 | Passivation out of sequence Procedure | 2 | mrl | mcc | rdh | time | |
---|---|---|---|---|---|---|---|---|---|
2 | 0:00 | MCC | BEGIN SEQUENCE: Prepare Passivation | Prepare Passivation | 2 | ||||
3 | 0:00 | MCC/MRL | Recall and make sure BOTH N2O Bottles & He Bottle 2 are still closed! Else continue with Abort Procedure | 2 | |||||
4 | 0:00 | MCC | Inform OPS of Passivation out of sequence | 2 | |||||
5 | 0:00 | MRL | Step Back/Leave MRL | 2 | |||||
6 | 0:00 | EGSE | Confirm all valve switches are in OFF position (Except OxDV & HPDV) | 2 | |||||
7 | 0:00 | OBDH | Confirm all valve switches are in OFF position (Except RMOxSV) | 2 | |||||
8 | 0:00 | MCC | BEGIN SEQUENCE: Passivation of GSE | Passivation of GSE | 2 | ||||
9 | 0:00 | EGSE | Open & Close OxDV STEPWISE until OxOutPT 0 Bar | 2 | |||||
10 | 0:00 | EGSE | Open OxDV | 2 | |||||
11 | 0:00 | EGSE | Open MPV3 | 2 | |||||
12 | 0:00 | EGSE | Confirm OxOutPT 0 bar | 2 | |||||
13 | 0:00 | EGSE | Close MPV3 | 2 | |||||
14 | 0:00 | EGSE | Open OxV1 | 2 | |||||
15 | 0:00 | EGSE | Confirm OxInPT1 & OxOutPT 0 Bar | 2 | |||||
16 | 0:00 | EGSE | Close OxV1 | 2 | |||||
17 | 0:00 | EGSE | Open OxV2 | 2 | |||||
18 | 0:00 | EGSE | Confirm OxInPT2 & OxOutPT 0 Bar | 2 | |||||
19 | 0:00 | EGSE | Close OxV2 | 2 | |||||
20 | 0:00 | EGSE | Close OxDV | 2 | |||||
21 | 0:00 | EGSE | Open HPDV | 2 | |||||
22 | 0:00 | EGSE | Confirm HPLPT 0 bar | 2 | |||||
23 | 0:00 | EGSE | Open HPV2 | 2 | |||||
24 | 0:00 | EGSE | Confirm HPLPT & HPPT2 0 bar | 2 | |||||
25 | 0:00 | EGSE | Close HPV2 | 2 | |||||
26 | 0:00 | EGSE | Close HPDV | 2 | |||||
27 | 0:00 | OBDH | Check RHPPT & ROxTPT 1 Bar (If more: continue with Passivation of Rocket, else continue at Finish Passivation) | 2 | |||||
28 | 0:00 | MCC | BEGIN:Passivation of Rocket | Passivation of Rocket | 2 | ||||
29 | 0:00 | OBDH | Open & Close stepwise RDV until RHPPT & ROxTPT 1 Bar | 2 | |||||
30 | 0:00 | OBDH | Confirm RHPPT & ROxTPT 1 Bar | 2 | |||||
31 | 0:00 | MRL | Go to MRL | 2 | |||||
32 | 0:00 | MRL | Remove HP section maintenance cover | 2 | |||||
33 | 0:00 | MRL | Open RMDV & Step Back, Wait until NCE-Tank is pressureless | 2 | |||||
34 | 0:00 | MCC | BEGIN SEQUENCE: Finish Passivation | Finish Passivation | 2 | ||||
35 | 0:00 | MRL | Go to MRL | 2 | |||||
36 | 0:00 | MRL | Close He Bottle 1 | 2 | |||||
37 | 0:00 | MCC/MRL | Write down remaining Pressure of He Bottle 1 | 2 | |||||
38 | 0:00 | MRL | Step back | 2 | |||||
39 | 0:00 | EGSE | Open HPDV | 2 | |||||
40 | 0:00 | EGSE | Open HPV1 | 2 | |||||
41 | 0:00 | EGSE | Confirm HPLPT & HPPT1 0 Bar | 2 | |||||
42 | 0:00 | EGSE | Close HPV1 | 2 | |||||
43 | 0:00 | EGSE | Close HPDV | 2 | |||||
44 | 0:00 | EGSE | Pressure Check | 2 | |||||
45 | 0:00 | MRL | Open MBV | 2 | |||||
46 | 0:00 | EGSE/ MRL | Check and compare pressure HPPT1 with HPPG1 | 2 | |||||
47 | 0:00 | MRL | Close MBV | 2 | |||||
48 | 0:00 | MRL | Safety is ensured | 2 | |||||
49 | 0:00 | MCC | Confirm to OPS that Safety is ensured | 1 | |||||
50 | 0:00 | MCC | END OF PROCEDURE | End | 1 |