procedure/LaunchProcedure.csv

17 KiB
Raw Blame History

1vers.v3.0Launch Procedure0MRLMCCRadar HillTime per step
2148:35EGSECheck CLD connection1
3148:35EGSESwitch on CLD via Battery & check voltage (24 Volt)1
4148:35EGSESwitch on the primary and secondary supply switches on the Control Panel101:00
5147:35EGSEPower on EGSEPower on EGSE1
6147:35EGSE@MRLSwitch on Sup_24V_20A & check voltage (ca. 27,2 Volt)1
7147:35EGSE@MRLSwitch on Sup_24V_10A & check voltage (ca. 27,2 Volt)1
8147:35EGSE@MRLSwitch on Sup_12V_10A & check voltage (ca. 13,8 Volt)1
9147:35EGSE@MRLSwitch on Bat_24V_20A & check voltage (ca. 27,9 Volt)1
10147:35EGSE@MRLSwitch on Bat_24V_10A & check voltage (ca. 27,9 Volt)1
11147:35EGSE@MRLSwitch on Bat_12V_10A & check voltage (ca. 13,8 Volt)1
12147:35EGSE@MRLSwitch on Sup_24V_40A1
13147:35EGSE@MRLSwitch on Sup_5V_10A103:00
14144:35EGSEConnect to cRIO1
15144:35EGSEStart FPGA_VI1
16144:35EGSEStart RT_VI1
17144:35EGSEConfirm PID-VI is running1
18144:35EGSERename PID-Logfile102:00
19142:35MRLConfirm working Personel is grounded1
20142:35MRLConnect Data UmbilicalConnect Data Umbilical100:30
21142:05EGSEStart EPS via EPS_ext1
22142:05EGSE@MRLSet Fuse in Power supply control panel1
23142:05EGSE@MRLInsert EPS_bat Bridge102:00
24140:05OBDHClear SD-Card-using FileZilla FTP01:00
25139:05OBDHConnect to sbRIO1
26139:05OBDHStart RT_Main1
27139:05MRLConfirm 3 beeps at OBC11
28139:05OBDHOpen RT_Sub_HMI1
29139:05OBDHConfirm Main Chute button is disabled1
30139:05MRLConfirm working Personel is grounded101:00
31138:05MRLRemove Pneumatic Line from Fueling arm1
32138:05MRLMove Fueling arm to rocket1
33138:05MRLCouple Helium coupling1
34138:05MRLCouple N2O coupling1
35138:05MRLAttach Pneumatic Line to Fueling arm103:00
36135:05MRLConfirm that Ignition Umbilical is disconnected1
37135:05EGSEBEGIN EGSE Valve and actuator check SequenceValve check1
38135:05MCCCheck if video recording is enabled @ MCC100:10
39134:55OBDHCheck EPS hardware100:10
40134:45EGSEStart PID data recording100:10
41134:35EGSECheck OxOutPT 0 Bar100:10
42134:25MRLClose HPNV100:10
43134:15EGSE/MRLSwitch OxDV to closed & check if magnetic valve LED is on100:10
44134:05EGSE/MRLSwitch HPDV to closed & check if magnetic valve LED is on100:10
45133:55EGSE/MRLCheck warning lamp 100:10
46133:45MRLRemove loose equipment103:00
47130:45EGSEActivate Heizi100:10
48130:35EGSEActivate N2O_Heater 1100:10
49130:25EGSEActivate N2O_Heater 2100:10
50130:15EGSEActivate HE_Heater100:10
51130:05EGSECheck OxV1 (CLD & RT_VI)100:10
52129:55EGSECheck OxV2 (CLD & RT_VI)100:10
53129:45EGSECheck MPV3 (CLD & RT_VI)100:10
54129:35EGSECheck HPV1 (CLD & RT_VI)100:10
55129:25EGSECheck HPV2 (CLD & RT_VI)100:10
56129:15EGSECheck MPV1/2 (CLD & RT_VI)100:10
57129:05EGSECheck RDV (CLD & RT_VI)100:10
58128:55EGSECheck RMOxOV (CLD & RT_VI)100:10
59128:45EGSECheck RMOxSV (CLD & RT_VI)100:10
60128:35EGSE/MRLVerify Bottle Temperatures @ OxT1 OxT2 HPT2100:10
61128:25EGSE/MRLVerify Water Temperatures @ Ox@T1 OxWT2 HPWT2100:10
62128:15OBDHVerify Heizi @ RDVT & RDVET100:10
63128:05EGSEDeactivate Heizi100:10
64127:55OBDHActivate Heizi100:10
65127:45OBDHCheck RDV100:10
66127:35OBDHCheck RNCEV100:10
67127:25OBDHCheck RMOxOV100:10
68127:15OBDHCheck RMOxSV100:10
69127:05OBDHConfirm RNCEV is disabled100:10
70126:55OBDHVerify Heizi @ RDVT & RDVET100:10
71126:45OBDH/TMTCCheck RF451-Link100:20
72126:25TMTCCheck GPS-lock300:20
73126:05TMTCCheck Telemega-Link100:20
74125:45OBDHTest Connection to STX3100:20
75125:25OBDHCheck if STX3 Package received by email100:30
76124:55MRLCheck MBV closed1
77124:55EGSECheck if all valve switches are in OFF position (Except OxDV & HPDV)110:00
78114:55MRL/EGSECheck loadcell by applying force to it100:20
79114:35OBDHCheck RHPPT shows atmosphere1
80114:35OBDHCheck ROxTPT shows atmosphere1
81114:35OBDHCheck RIHPT shows atmosphere1
82114:35OBDHCheck RCCPT shows atmosphere1
83114:35OBDHCheck RBaro1 shows atmosphere1
84114:35OBDHCheck RBaro2 shows atmosphere1
85114:35EGSECheck HPPT1 shows 0 bar100:20
86114:15EGSECheck HPPT2 shows 0 bar1
87114:15EGSECheck HPLPT shows 0 bar1
88114:15EGSECheck OxInPT1 shows 0 bar1
89114:15EGSECheck OxInPT2 shows 0 bar1
90114:15EGSECheck OxOutPT shows 0 bar100:20
91113:55EGSE/MRLSwitch on N2O coupling & check if magnetic valve LED is on1
92113:55EGSE/MRLSwitch on HE coupling & check if magnetic valve LED is on1
93113:55EGSE/MRLSwitch on swivle arm & check if magnetic valve LED is on1
94113:55EGSESwitch off swivel arm & HE coupling & N2O coupling101:00
95112:55MRLConfirm that Ignition Umbilical is disconnected1
96112:55MRLConnect Ignition test Receptical1
97112:55EGSE@MRLPlug in Bridges B1 and B21
98112:55MRLConfirm Soundsignal from Ignition Umbilical2
99112:55EGSETurn on Ignition Secure1
100112:55EGSE/OBDHTurn on Ignition Switch for 2 Second & Confirm ignition signal received at sbRio1
101112:55EGSETurn off Ignition Secure1
102112:55EGSE@MRLRemove Bridges B1 and B21
103112:55MRLRemove Ignition test Receptical103:00
104109:55MCCGround Segment Pressure Test (PHASE YELLOW) Ground Pressure Test1
105109:55MRLConfirm that all hatches and covers are closed101:00all hatches
106108:55MRLCheck HE bottle 1 connector is attached1
107108:55MRLCheck HE bottle 2 connector is attached1
108108:55MRLCheck N2O bottle 1 connector is attached1
109108:55MRLCheck N2O bottle 2 connector is attached1
110108:55MRLCheck hose between HPSM & N2OSM is connected on both ends1
111108:55MRLCheck hose between HPSM & Flight Segment is connected on both ends1
112108:55MRLCheck hose between N2OSM & Flight Segment is connected on both ends1
113108:55MRLCheck Pneumatik hose is connected on both ends102:00
114106:55MRLPut on safety equipment2
115106:55MRLMove into Position to open HE Bottle 12
116106:55MRLCheck if HPV1 is closed2
117106:55MRLCheck if MPV1/2 is closed2
118106:55MRLOpen HE Bottle 1201:00
119105:55MRLCheck & compare pressure HPPT1 with HPPG1 (max 300 bar)2
120105:55MRLCheck Gastech Silver HPPR1 (max 300 to 50 bar)2
121105:55MRLCheck Harris PPR (50 to 8 bar)2
122105:55MRLCheck pneumatic PPG (8 bar)2
123105:55MRLStep back201:00
124104:55EGSEConfirm HPPT1 is at 300 Bar1??
125104:55EGSEConfirm HPLPT less than 10 Bar1
126104:55EGSE/MRLOpen & Close HPV1 SHORTLY & Check HPPT12
127104:55EGSE/MRLOpen & Close HPV2 SHORTLY & Check HPPT2 0 bar2
128104:55EGSE/MRLOpen & Close HPDV SHORTLY & Check HPLPT 0 bar2
129104:55EGSE/MRLOpen & Close OxV1 SHORTLY2
130104:55EGSE/MRLOpen & Close OxV2 SHORTLY2
131104:55EGSE/MRLOpen & Close OxDV SHORTLY2
132104:55EGSE/MRLOpen & Close MPV3 SHORTLY2
133104:55EGSECheck HPLPT & OxOutPT 0 Bar201:30
134103:25EGSEDecouple N2O coupling2
135103:25EGSEDecouple Helium coupling200:20
136103:05EGSEMove arm away from rocket2
137103:05EGSEMove arm to rocket201:00
138102:05MRLClose HE Bottle 1 and check HPSM for leakage (If leakage occurs Abort)201:00
139101:05MRLOpen HPNV 1/8 Rev2
140101:05MRLOpen MBV2
141101:05EGSE/MRLCheck and compare pressure HPPT1 with HPPG1 0 Bar2
142101:05MRLClose MBV200:30
143100:35MRLSafety is ensured1
144100:35MCCMiS to MRL1
145100:35EGSESwitch off N20 coupling1
146100:35EGSESwitch off HE coupling1
147100:35MRLRelease Pneumatic lines100:20
148100:15EGSEConfirm Fueling arm is off1
149100:15EGSECheck OxOutPT and HPLPT 0 bar1
150100:15MRLCouple Helium coupling100:30
15199:45MRLCouple N2O coupling100:30
15299:15MRLHOLD / RESTART1
15399:15MRLBEGIN Arming Rocket SEQUENCE Part 1Arming 11
15499:15MRLConnect Ignition Umbilical100:30
15598:45MRLTurn on GoPro Camera at end of Launch Rail100:20
15698:25MRLInsert EPS Bridges103:00
15795:25MRLConfirm Bridge Hatch is Secured100:20
15895:05EGSE@MRLreturn to MCC1
15995:05OPSElevate MRL to 90 degrees105:00
16090:05EGSEPowercycle EPS to to start flight mode on Telemega100:30
16189:35EGSECalibrate loadcell (Set to 0)101:00
16288:35MCCBEGIN Pressure Test Flight Segment (PHASE YELLOW) Pressure Test Rocket2
16388:35MRLPut on safety equipment200:30
16488:05MRLOpen HE Bottle 1201:00
16587:05MRLStep back2
16687:05EGSEOpen & Close stepwise MPV1/MPV2 to 50 Bar @ OxInPT1 & OxInPT22
16787:05MRLCheck & compare OxInPT1 with OxInPG1 based on Bottle temperature (max 50 bar)2
16887:05MRLCheck & compare pressure OxInPT2 with OxInPG2 based on Bottle temperature (max 50 bar)2
16987:05MRLCheck Temperature of N2O Bottle 1 @OxT1 & OxWT1 (max 22C)2
17087:05MRLCheck Temperature of N2O Bottle 2 @OxT2 & OxWT2 (max 22C)201:30
17185:35MRLOpen He Bottle 22
17285:35MRLCheck & compare pressure HPPT2 with HPPG2 (max 315 bar)201:00
17384:35ALLCAUTION!2
17484:35MRLOpen N2O Bottle 12
17584:35MRL/EGSECheck & compare pressure OxInPT 1 with OxInPG 1 (max 50 bar)202:00
17682:35MRLOpen N2O Bottle 22
17782:35MRL/EGSECheck & compare pressure OxInPT 2 with OxInPG 2 (max 50 bar)202:00
17880:35MRLInsert Ignition Bridges B1 and B2 into EGSE202:00
17978:35MRLConfirm Soundsignal from Ignition Umbilical2
18078:35MRLClose ComTerm2
18178:35ALLClear Launchpad and inform OPS210:00
18268:35KLPStart Camera Karsten Lapp<70>hn2
18368:35MCCHOLD / RESTARTHOLD / RESTART2
18468:35MCCBegin of Ox FUELING Sequence (PHASE RED)Ox Fueling (PHASE RED)3
18568:35TMTCConfirm GPS-lock3
18668:35OBDHAcknowledge start of Fueling301:00CHANGE to 3 steps
18767:35EGSEOpen & Close HPV1 to 50 Bar @ ROxTPT (stop at 30 bar and wait 30 seconds to check for leakage)3
18867:35EGSEOpen & Close HPV1 to more than 50 Bar @ RHPPT and check ROxTPT 50 Bar3
18967:35EGSECheck if HPV1 is closed3
19067:35OBDHOpen RDV shortly, to check tightness @ RHPPT & ROxTPT (If leakages occur Abort)3
19167:35EGSEOpen MPV1/MPV23
19267:35EGSEOpen & Close stepwise MPV3 to 50 Bar @ OxOutPT3
19367:35EGSEClose MPV1/MPV23
19467:35EGSECheck & compare OxOutPT with OxInPT13
19567:35EGSECheck if RHPPT & ROxTPT more than OxInPT1, If less Open & Close HPV13
19667:35EGSEZero OxTank Mass3
19767:35MCCWrite down Time3
19867:35EGSEOpen OxV1 304:00
19963:35OBDHOpen stepwise RDV until N2O bottle empty or 25kg OxTankMass, keep temperatures RDVT and RDVET above 10<31>C and Check delta ROxTPT and OxInPT1330:00
20033:35EGSEClose OxV1300:10
20133:25EGSECheck if Pressure rises in OxPT1, if Pressure rises relief via OxV1 or wait for Pressure relief valve301:00
20232:25EGSECheck & compare OxOutPT with OxInPT23
20332:25EGSECheck & compare RHPPT & ROxTPT 50 Bar and more than OxInPT2, If less Open & Close HPV13
20432:25EGSEOpen OxV2 3
20532:25OBDHOpen stepwise RDV to 25kg OxTankMass, keep temperatures RDVT and RDVET above 10<31>C and Check delta OxTPT and OxInPT1320:00
20612:25EGSEClose OxV2 300:10
20712:15EGSECheck if Pressure rises in OxPT2, if Pressure rises relief via OxV2 or wait for Pressure relief valve301:00
20811:15EGSEOpen stepwise OxDV until OxOutPT 0 Bar3
20911:15OBDHCheck ROxCV for tightness @ ROxTPT3
21011:15EGSEClose OxDV301:00
21110:15EGSEWrite down OxTankMass3
21210:15MCCProvied OxTankMass and Temperature Readings to Windwaiting Station300:30
21309:45EGSEConfirm OxV1 & OxV2 closed3
21409:45EGSECheck OxOutPT 0 Bar3
21509:45EGSEDecouple N2O coupling300:20
21609:25MCCConfirm End of Oxidator Fueling to OPS300:15
21709:10OBDH/TMTCCheck RF451-Link300:20
21808:50TMTCCheck GPS-lock300:20
21908:30TMTCCheck Telemega-Link300:20
22008:10MCCScheduled HOLD3
22108:10ALLAlign MRL to Launch Trajectory3
22208:10MCCConfirm MRL adjustment is final3
22308:10ALLTalk through Launch Sequence3
22408:10AVCStart Video Recording in BlockHouse3
22508:10MCCTurn audio volume down3
22608:10MCCCONTINUE AFTER HOLD
22708:10MCCBEGIN Switching to Internal Power SequenceSwitch to Internal Power3
22808:10EGSESwitch to internal Power300:20
22907:50OBDHConfirm EPS Voltages are within limits300:10
23007:45OBDHConfirm RF451 Transmitting300:05
23107:20OBDH/TMTCConfirm RF451-Link300:20
23207:40TMTCConfirm GPS-lock300:20
23307:00TMTCConfirm Telemega-Link300:20
23406:40OBDHSwitch to PREAMRED300:10
23506:30PYLConfirm Payload is running300:20
23606:10AVCCheck if videorecording @ MCC is running300:05
23706:05MCCHigh Pressure FulingHP Fueling3
23806:05EGSEOpen and close HPV1 stepwise until RHPPT 300 Bar or pressure equal to HE Bottle 13
23906:05EGSEOpen and close HPV2 stepwise until RHPPT 300 Bar 3
24006:05EGSEOpen and close HPDV stepwise until HPLPT 0 Bar 3
24106:05EGSECheck HPDV closed3
24206:05OBDH/EGSECheck for leakage HPLPT 0 Bar & RHPPT 300 Bar 302:00
24304:05OBDHAcknowledge end of Fueling300:10
24403:55MCCConfirm End of Fueling to OPS300:20
24503:35MCCBEGIN of Moving Fueling Arm Away SequenceMove Fueling Arm away300:10
24603:25EGSEConfirm HPV1 & HPV2 closed300:10
24703:15EGSECheck HPLPT 0 Bar 300:10
24803:05EGSEDecouple Helium coupling300:20
24902:45EGSEConfirm Helium coupling is disconnected300:10
25002:35EGSEMove fueling arm away from rocket300:40
25101:55MCCConfirm Fueling Arm away to OPS300:15
25201:40MCCPrepare for Launch300:10
25301:30OBDHConfirm ready for launch300:10
25401:20EGSEConfirm ready for launch300:10
25501:10MCCSet Go/No-Go System to Go300:10
25601:00MCCWait for Authorization for Launch300:00
25701:00MCCBEGIN of Ignition SequenceIgnition Sequence400:10
25800:50OBDHARM400:05
25900:45OBDHConfirm all status indicators green400:05
26000:40OBDHEthernet Disconnect400:30
26100:10EGSETurn on Ignition Secure400:07
26200:03EGSET-3: Ignition400:03
26300:00OBDHT+0: Verify RMOxOV Open (Launched)400:00
26400:00EGSET+1: Turn OFF Ignition4
26500:00EGSET+5: Turn OFF Ignition Secure4
26600:00OBDHT+20: Verify RMOxOV Closed and RMOxSV Open (Cruise)4
26700:00OBDHT+50: Verify RNCEV Open (Drogue)4
26800:00OBDHT+310: Verify Main Chute Deployed and RDV Open (Main)4
26900:00OBDHT+600: Verify (Landed)4
27000:00MCCSTART OF PASSIVATION (PHASE YELLOW) (Write down Time)Passivation2
27100:00MCCTurn audio volume up2
27200:00TMTCCheck ROxTPT & RHPPT 1 Bar, if more: Open & Close stepwise RDV2
27300:00MRLGo to Testrig, close N2O Bottle 1 & N2O Bottle 2 and return to BlockHouse2
27400:00EGSEOpen OxDV2
27500:00EGSEOpen OxV12
27600:00EGSECheck OxInPT1 & OxOutPT 0 Bar2
27700:00EGSEClose OxV12
27800:00EGSEOpen OxV22
27900:00EGSECheck OxInPT2 & OxOutPT 0 Bar2
28000:00EGSEClose OxV22
28100:00EGSEClose OxDV 2
28200:00MRLGo to MRL, confirm OxInPG1 & OxInPG2 0 Bar, else return to BlockHouse, then close HE Bottle2
28300:00MRLWrite down remaining Pressure of HE Bottle2
28400:00EGSEOpen HPDV2
28500:00EGSEOpen HPV22
28600:00EGSECheck pressure HPLPT & HPPT2 0 Bar2
28700:00EGSEClose HPV22
28800:00EGSEClose HPDV2
28900:00MRLGo to Testrig, confirm HPPG2 0 Bar, else return to BlockHouse, then open ComTerm2
29012960:00MRLClose N2 Bottle2
29100:00MRLWrite down remaining Pressure of N2 Bottle2
29200:00MRLStep back2
29300:00MRLCheck EPV manometer less than 6 bar2
29400:00MRLOpen MBV2
29500:00EGSECheck and compare pressure HPPT1 with HPPG12
29600:00MRLClose MBV2
29700:00MRLTake out B1 & B2 Bridges2
29800:00MRLSafety is ensured2
29900:00MCCTurn off area warning light and open barrier1
30000:00MCCEND OF PASSIVATION (PHASE GREEN) (Write down Time)1
30100:00MCCSTART DATA COLLECTION (Write down Time)Collection1
30200:00AVCTurn off GoPro & Camcorder & Stop BlockHouse Video recording1
30300:00EGSECopy PID.vi.tdms & save to new name1
30400:00EGSEWait for buffer storage process to be finished1
30500:00EGSEsave data files from cRIO to PC1
30600:00AVCEnd audio recording1
30700:00MCCEND OF PROCEDURE (Write Down Time)1
30800:00AVCSave video & audio data on external HDD1
30900:00MCCStop RT_CD.vi and save logfile to external HDD1
31000:00MCCPROCEDURE FINISHEDEnd1