1 | vers. | v4.3 | Launch Procedure | 0 | MRL | MCC | RdHill | Time per step | ||
---|---|---|---|---|---|---|---|---|---|---|
2 | 147:20 | MCC | BEGIN SEQUENCE: Power on EGSE | Power on EGSE | 1 | |||||
3 | 147:20 | EGSE | Check CLD connection | 1 | ||||||
4 | 147:20 | EGSE | Switch ON CLD via Battery & check voltage (24 Volt) | 1 | ||||||
5 | 147:20 | EGSE | Switch ON the primary and secondary supply switches on the Control Panel | 1 | 01:00 | |||||
6 | 146:20 | EGSE@MRL | Switch ON Sup_24V_20A & check voltage (ca. 27,2 Volt) | 1 | ||||||
7 | 146:20 | EGSE@MRL | Switch ON Sup_24V_10A & check voltage (ca. 27,2 Volt) | 1 | ||||||
8 | 146:20 | EGSE@MRL | Switch ON Sup_12V_10A & check voltage (ca. 13,8 Volt) | 1 | ||||||
9 | 146:20 | EGSE@MRL | Switch ON Bat_24V_20A & check voltage (ca. 27,9 Volt) | 1 | ||||||
10 | 146:20 | EGSE@MRL | Switch ON Bat_24V_10A & check voltage (ca. 27,9 Volt) | 1 | ||||||
11 | 146:20 | EGSE@MRL | Switch ON Bat_12V_10A & check voltage (ca. 13,8 Volt) | 1 | ||||||
12 | 146:20 | EGSE@MRL | Switch ON Sup_24V_40A | 1 | ||||||
13 | 146:20 | EGSE@MRL | Switch ON Sup_5V_10A | 1 | 03:00 | |||||
14 | 143:20 | EGSE | Connect to cRIO | 1 | ||||||
15 | 143:20 | EGSE | Start FPGA_VI | 1 | ||||||
16 | 143:20 | EGSE | Start RT_VI | 1 | ||||||
17 | 143:20 | EGSE | Confirm PID-VI is running | 1 | ||||||
18 | 143:20 | EGSE | Rename PID-Logfile | 1 | 02:00 | |||||
19 | 141:20 | MRL | Confirm working Personel is grounded | 1 | ||||||
20 | 141:20 | EGSL@MRL | Confirm all 8 Groundingbridges are inserted | 1 | ||||||
21 | 141:20 | MCC | BEGIN SEQUENCE: Connect Data Umbilical | Connect Data Umbilical | 1 | 00:30 | ||||
22 | 140:50 | EGSE | Turn on EPS_BAT | 1 | ||||||
23 | 140:50 | EGSE | Turn on EPS_EXT | 1 | ||||||
24 | 140:50 | EGSE@MRL | Remove 7 Grounding Bridges and leave EPS_BAT inserted | 1 | ||||||
25 | 140:50 | EGSE@MRL | Insert EPS_EXT Fuse in Power Supply Control Panel | 1 | ||||||
26 | 140:50 | EGSE@MRL | Confirm green LED at EPS_EXT Fuse is on | 1 | ||||||
27 | 140:50 | EGSE@MRL | Insert Main_Bus Fuse in Power Supply Control Panel | 1 | ||||||
28 | 140:50 | EGSE@MRL | Confirm LED at Main_Bus Fuse is OFF. Else Pull fuse and insert all Grounding Bridges | 1 | ||||||
29 | 140:50 | EGSE@MRL | Set remaining Fuses (except Payload Fuse) and check for green LED | 1 | ||||||
30 | 140:50 | EGSE | Turn OFF EPS_BAT | 1 | ||||||
31 | 140:50 | EGSE@MRL | Confirm Main bus LED is on. | 1 | ||||||
32 | 140:50 | EGSE | Start EPS via EPS_ext | 1 | ||||||
33 | 140:50 | OBDH | Clear SD-Card-using FileZilla FTP | 1 | 01:00 | |||||
34 | 139:50 | OBDH | Connect to sbRIO | 1 | ||||||
35 | 139:50 | OBDH | Start RT_Main | 1 | ||||||
36 | 139:50 | MRL | Confirm 3 beeps at OBC1 | 1 | ||||||
37 | 139:50 | OBDH | Open RT_Sub_HMI | 1 | ||||||
38 | 139:50 | OBDH | Confirm Main Chute button is disabled | 1 | ||||||
39 | 139:50 | EGSE@MRL | Insert Payload Fuse | 1 | ||||||
40 | 139:50 | EGSE@MRL | Confirm green LED at Payload Fuse is on | 1 | ||||||
41 | 139:50 | MCC | BEGIN SEQUENCE: Connect Fueling arm | Connect Fueling Arm | 1 | |||||
42 | 139:50 | MRL | Confirm working Personel is grounded | 1 | 01:00 | |||||
43 | 138:50 | MRL | Remove Pneumatic Line from Fueling arm | 1 | ||||||
44 | 138:50 | MRL | Move Fueling arm to rocket | 1 | ||||||
45 | 138:50 | MRL | Couple Helium coupling | 1 | ||||||
46 | 138:50 | MRL | Couple N2O coupling | 1 | ||||||
47 | 138:50 | MRL | Reattach Pneumatic Line to Fueling arm | 1 | 03:00 | |||||
48 | 135:50 | EGSE | BEGIN SEQUENCE: EGSE Valve and Actuator check | EGSE Valve & Actuator Check | 1 | |||||
49 | 135:50 | MCC | Confirm that video recording is enabled @ MCC | 1 | 00:10 | |||||
50 | 135:50 | MRL | Confirm that Ignition Umbilical is disconnected | 1 | ||||||
51 | 135:40 | OBDH | Check EPS hardware Voltages | 1 | 00:10 | |||||
52 | 135:30 | EGSE | Start PID data recording | 1 | 00:10 | |||||
53 | 135:20 | MRL | Close HPNV | 1 | 00:10 | |||||
54 | 135:10 | EGSE/MRL | Switch OxDV to closed & check if magnetic valve LED is on | 1 | 00:10 | |||||
55 | 135:00 | EGSE/MRL | Switch HPDV to closed & check if magnetic valve LED is on | 1 | 00:10 | |||||
56 | 134:50 | EGSE/MRL | Check warning lamp on HPSM | 1 | 00:10 | |||||
57 | 134:40 | MRL | Remove loose equipment | 1 | 03:00 | |||||
58 | 131:40 | EGSE | Activate Heizi | 1 | 00:10 | |||||
59 | 131:30 | EGSE | Activate N2O_Heater 1 | 1 | 00:10 | |||||
60 | 131:20 | EGSE | Activate N2O_Heater 2 | 1 | 00:10 | |||||
61 | 131:10 | EGSE | Activate He_Heater | 1 | 00:10 | |||||
62 | 131:00 | OBDH | Verify Heizi @ RDVT & RDVET | 1 | 00:10 | |||||
63 | 130:50 | EGSE/MRL | Verify Bottle Temperatures @ OxT1, OxT2, HPT2 | 1 | 00:10 | |||||
64 | 130:40 | EGSE/MRL | Verify Water Temperatures @ Ox@T1, OxWT2, HPWT2 | 1 | 00:10 | |||||
65 | 130:30 | EGSE | Deactivate Heizi | 1 | 00:10 | |||||
66 | 130:20 | EGSE | Check OxV1 (CLD & RT_VI) | 1 | 00:10 | |||||
67 | 130:10 | EGSE | Check OxV2 (CLD & RT_VI) | 1 | 00:10 | |||||
68 | 130:00 | EGSE | Check MPV3 (CLD & RT_VI) | 1 | 00:10 | |||||
69 | 129:50 | EGSE | Check HPV1 (CLD & RT_VI) | 1 | 00:10 | |||||
70 | 129:40 | EGSE | Check HPV2 (CLD & RT_VI) | 1 | 00:10 | |||||
71 | 129:30 | EGSE | Check MPV1/2 (CLD & RT_VI) | 1 | 00:10 | |||||
72 | 129:20 | EGSE | Check RDV (CLD & RT_VI) | 1 | 00:10 | |||||
73 | 129:10 | EGSE | Check RMOxOV (CLD & RT_VI) | 1 | 00:10 | |||||
74 | 129:00 | EGSE | Check RMOxSV (CLD & RT_VI) | 1 | 00:10 | |||||
75 | 128:50 | OBDH | Activate Heizi | 1 | 00:10 | |||||
76 | 128:40 | OBDH | Verify Heizi @ RDVT & RDVET | 1 | 01:00 | |||||
77 | 127:40 | OBDH | Check RDV | 1 | 00:10 | |||||
78 | 127:30 | OBDH | Check RNCEV | 1 | 00:10 | |||||
79 | 127:20 | OBDH | Check RMOxOV | 1 | 00:10 | |||||
80 | 127:10 | OBDH | Check RMOxSV | 1 | 00:10 | |||||
81 | 127:00 | OBDH | Confirm RNCEV is disabled | 1 | 00:10 | |||||
82 | 125:00 | MRL | Confirm MBV closed | 1 | ||||||
83 | 125:00 | EGSE | Confirm that all valve switches are in OFF position (Except OxDV & HPDV) | 1 | 10:00 | |||||
84 | 115:00 | MRL/EGSE | Check loadcell by applying force to it | 1 | 00:20 | |||||
85 | 114:40 | OBDH | Check RHPPT shows atmosphere | 1 | ||||||
86 | 114:40 | OBDH | Check ROxTPT shows atmosphere | 1 | ||||||
87 | 114:40 | OBDH | Check RIHPT shows atmosphere | 1 | ||||||
88 | 114:40 | OBDH | Check RCCPT shows atmosphere | 1 | ||||||
89 | 114:40 | OBDH | Check RBaro1 shows atmosphere | 1 | ||||||
90 | 114:40 | OBDH | Check RBaro2 shows atmosphere | 1 | ||||||
91 | 114:40 | EGSE | Check HPPT1 shows 0 bar | 1 | 00:20 | |||||
92 | 114:20 | EGSE | Check HPPT2 shows 0 bar | 1 | ||||||
93 | 114:20 | EGSE | Check HPLPT shows 0 bar | 1 | ||||||
94 | 114:20 | EGSE | Check OxInPT1 shows 0 bar | 1 | ||||||
95 | 114:20 | EGSE | Check OxInPT2 shows 0 bar | 1 | ||||||
96 | 114:20 | EGSE | Check OxOutPT shows 0 bar | 1 | 00:20 | |||||
97 | 114:00 | EGSE/MRL | Switch on N2O coupling & check if magnetic valve LED is on | 1 | ||||||
98 | 114:00 | EGSE/MRL | Switch on He coupling & check if magnetic valve LED is on | 1 | ||||||
99 | 114:00 | EGSE/MRL | Switch on swivle arm & check if magnetic valve LED is on | 1 | ||||||
100 | 114:00 | EGSE | Switch off swivel arm & He coupling & N2O coupling | 1 | 01:00 | |||||
101 | 114:00 | MCC | BEGIN SEQUENCE: Ignition signal Test | Ignition signal Test | 1 | 01:00 | ||||
102 | 113:00 | MRL | Confirm that Ignition Umbilical is disconnected | 1 | ||||||
103 | 113:00 | MRL | Connect Ignition test receptical | 1 | ||||||
104 | 113:00 | EGSE@MRL | Plug in Bridges B1 and B2 | 1 | ||||||
105 | 113:00 | MRL | Confirm Soundsignal from Ignition Umbilical | 1 | ||||||
106 | 113:00 | EGSE | Turn on Ignition Secure Switch | 1 | ||||||
107 | 113:00 | EGSE/OBDH | Turn on Ignition Switch for 2 Second & Confirm ignition signal received at sbRio | 1 | ||||||
108 | 113:00 | EGSE/OBDH | Confirm that Ignition Switch is switched off | 1 | ||||||
109 | 113:00 | EGSE | Turn off Ignition Secure Switch | 1 | ||||||
110 | 113:00 | EGSE@MRL | Remove Bridges B1 and B2 | 1 | ||||||
111 | 113:00 | MRL | Remove Ignition test receptical | 1 | 03:00 | |||||
112 | 110:00 | MCC | BEGIN SEQUENCE: pneumatic pressure test (PHASE YELLOW) | Pneumatic Pressure Test | 1 | |||||
113 | 110:00 | MRL | Confirm that all hatches are closed | 1 | 01:00 | |||||
114 | 109:00 | MRL | Check He bottle 1 connector is attached | 1 | ||||||
115 | 109:00 | MRL | Check He bottle 2 connector is attached | 1 | ||||||
116 | 109:00 | MRL | Check N2O bottle 1 connector is attached | 1 | ||||||
117 | 109:00 | MRL | Check N2O bottle 2 connector is attached | 1 | ||||||
118 | 109:00 | MRL | Check hose between HPSM & N2OSM is connected on both ends | 1 | ||||||
119 | 109:00 | MRL | Check hose between HPSM & Flight Segment is connected on both ends | 1 | ||||||
120 | 109:00 | MRL | Check hose between N2OSM & Flight Segment is connected on both ends | 1 | ||||||
121 | 109:00 | MRL | Check Pneumatik hose is connected on both ends | 1 | 02:00 | |||||
122 | 107:00 | MRL | Put on safety equipment | 2 | ||||||
123 | 107:00 | MRL | Move into Position to open He Bottle 1 | 2 | ||||||
124 | 107:00 | MRL | Confirm MBV is closed | 2 | ||||||
125 | 107:00 | EGSE | Confirm if HPV1 is closed | 2 | ||||||
126 | 107:00 | EGSE | Confirm MPV1/2 is closed | 2 | ||||||
127 | 107:00 | MRL | Open He Bottle 1 | 2 | 01:00 | |||||
128 | 106:00 | MRL | Check & compare pressure HPPT1 with HPPG1 (max 300 bar) | 2 | ||||||
129 | 106:00 | MRL | Check Gastech Silver HPPR1 (max 300 to 50 bar) | 2 | ||||||
130 | 106:00 | MRL | Check Harris PPR (50 to 8 bar) | 2 | ||||||
131 | 106:00 | MRL | Check pneumatic PPG (8 bar) | 2 | ||||||
132 | 106:00 | MRL | Step back | 2 | 01:00 | |||||
133 | 105:00 | EGSE/MRL | Open & Close HPV1 SHORTLY & Check HPPT1 | 2 | ||||||
134 | 105:00 | EGSE | Confirm HPPT1 is at 300 Bar | 2 | ||||||
135 | 105:00 | EGSE | Confirm HPLPT less than 10 Bar | 2 | ||||||
136 | 105:00 | EGSE/MRL | Open & Close HPV2 SHORTLY & Check HPPT2 0 bar | 2 | ||||||
137 | 105:00 | EGSE/MRL | Open & Close HPDV SHORTLY & Check HPLPT 0 bar | 2 | ||||||
138 | 105:00 | EGSE/MRL | Open & Close OxV1 SHORTLY | 2 | ||||||
139 | 105:00 | EGSE/MRL | Open & Close OxV2 SHORTLY | 2 | ||||||
140 | 105:00 | EGSE/MRL | Open & Close OxDV SHORTLY | 2 | ||||||
141 | 105:00 | EGSE/MRL | Open & Close MPV3 SHORTLY | 2 | ||||||
142 | 105:00 | EGSE | Check HPLPT & OxOutPT 0 Bar | 2 | 01:30 | |||||
143 | 103:30 | EGSE | Decouple N2O coupling | 2 | ||||||
144 | 103:30 | EGSE | Decouple Helium coupling | 2 | 00:20 | |||||
145 | 103:10 | EGSE | Move arm away from rocket | 2 | ||||||
146 | 103:10 | EGSE | Move arm to rocket | 2 | 01:00 | |||||
147 | 102:10 | MRL | Close He Bottle 1 and check HPSM for leakage (If leakage occurs Abort) | 2 | 01:00 | |||||
148 | 101:10 | MRL | Open HPNV 1/8 Rev | 2 | ||||||
149 | 101:10 | MRL | Open MBV | 2 | ||||||
150 | 101:10 | EGSE/MRL | Check and compare pressure HPPT1 with HPPG1 0 Bar | 2 | ||||||
151 | 101:10 | MRL | Close MBV | 2 | 00:30 | |||||
152 | 100:40 | MRL | Safety is ensured | 2 | ||||||
153 | 100:40 | MCC | MiS to MRL | 1 | ||||||
154 | 100:40 | EGSE | Switch off N20 coupling | 1 | ||||||
155 | 100:40 | EGSE | Switch off He coupling | 1 | ||||||
156 | 100:40 | MRL | Release Pneumatic lines of couplings | 1 | 00:20 | |||||
157 | 100:20 | EGSE | Confirm Fueling arm is switched off | 1 | ||||||
158 | 100:20 | EGSE | Check OxOutPT and HPLPT 0 bar | 1 | ||||||
159 | 100:20 | MRL | Couple Helium coupling | 1 | 00:30 | |||||
160 | 99:50 | MRL | Couple N2O coupling | 1 | 00:30 | |||||
161 | 99:20 | MRL | HOLD | HOLD | 1 | |||||
162 | 99:20 | MCC | CONTINUE AFTER HOLD | |||||||
163 | 99:20 | MRL | BEGIN SEQUENCE: Arming Rocket Part 1 | Arming Rocket Pt.1 | 1 | |||||
164 | 98:50 | MRL | Turn on GoPro Camera at end of Launch Rail | 1 | 00:20 | |||||
165 | 99:20 | MRL | Connect Ignition Umbilical | 1 | 00:30 | |||||
166 | 98:30 | MRL | Insert all EPS Bridges | 1 | 03:00 | |||||
167 | 95:30 | MRL | Confirm Bridge Hatch is Secured | 1 | 00:20 | |||||
168 | 95:10 | EGSE@MRL | return to MCC | 1 | ||||||
169 | 95:10 | OPS | Elevate MRL to 90 degrees | 1 | 05:00 | |||||
170 | 90:10 | EGSE | Powercycle EPS to to start flight mode on Telemega | 1 | 00:30 | |||||
171 | 89:40 | EGSE | Calibrate loadcell (Set to 0) | 1 | 01:00 | |||||
172 | 88:40 | MCC | BEGIN SEQUENCE: Fueling Preparations (PHASE YELLOW) | Fueling Preparations | 2 | |||||
173 | 88:40 | MRL | Put on safety equipment | 2 | 00:30 | |||||
174 | 88:10 | MRL | Open He Bottle 1 | 2 | 01:00 | |||||
175 | 87:10 | MRL | Step back | 2 | ||||||
176 | 87:10 | EGSE | Open & Close STEPWISE MPV1/MPV2 to 50 Bar @ OxInPT1 & OxInPT2 | 2 | ||||||
177 | 87:10 | EGSE/MRL | Check & compare OxInPT1 with OxInPG1 based on Bottle temperature (max 50 bar) | 2 | ||||||
178 | 87:10 | EGSE/MRL | Check & compare pressure OxInPT2 with OxInPG2 based on Bottle temperature (max 50 bar) | 2 | ||||||
179 | 87:10 | EGSE/MRL | Check Temperature of N2O Bottle 1 @OxT1 & OxWT1 (max 22C) | 2 | ||||||
180 | 87:10 | EGSE/MRL | Check Temperature of N2O Bottle 2 @OxT2 & OxWT2 (max 22C) | 2 | 01:30 | |||||
181 | 85:40 | MRL | Open He Bottle 2 | 2 | ||||||
182 | 85:40 | EGSE/MRL | Check & compare pressure HPPT2 with HPPG2 (max 315 bar) | 2 | 01:00 | |||||
183 | 84:40 | ALL/MRL | CAUTION! | 2 | ||||||
184 | 84:40 | MRL | Open N2O Bottle 1 | 2 | ||||||
185 | 84:40 | MRL/EGSE | Check & compare pressure OxInPT 1 with OxInPG 1 (max 50 bar) | 2 | 02:00 | |||||
186 | 82:40 | MRL | Open N2O Bottle 2 | 2 | ||||||
187 | 82:40 | MRL/EGSE | Check & compare pressure OxInPT 2 with OxInPG 2 (max 50 bar) | 2 | 02:00 | |||||
188 | 80:40 | MRL | Insert Ignition Bridges B1 and B2 into EGSE | 2 | 02:00 | |||||
189 | 78:40 | MRL | Confirm Soundsignal from Ignition Umbilical | 2 | ||||||
190 | 78:40 | MRL | Close ComTerm | 2 | ||||||
191 | 78:40 | ALL | Clear Launchpad and inform OPS | 2 | 10:00 | |||||
192 | 68:40 | KLP | Start Camera Karsten Lapp<70>hn | 2 | ||||||
193 | 68:40 | MCC | HOLD | HOLD | 2 | |||||
194 | 68:40 | MCC | CONTINUE AFTER HOLD | |||||||
195 | 68:40 | MCC | BEGIN SEQUENCE Ox Fueling (PHASE RED) | Ox Fueling (PHASE RED) | 3 | |||||
196 | 68:40 | MCC | Announce end of Radio Silence | 3 | ||||||
197 | 126:50 | OBDH/TMTC | Check RF451-Link | 1 | 00:20 | |||||
198 | 126:30 | TMTC | Confirm GPS-lock | 1 | 00:20 | |||||
199 | 126:10 | TMTC | Confirm Telemega-Link | 1 | 00:20 | |||||
200 | 125:50 | OBDH | Test Connection to STX3 | 1 | 00:20 | |||||
201 | 125:30 | OBDH | Confirm that STX3 Package received by email | 1 | 00:30 | |||||
202 | 125:30 | MCC | Request Permission to begin fueling from OPS | 1 | 03:00 | |||||
203 | 68:40 | OBDH | Acknowledge start of Fueling | 3 | 01:00 | |||||
204 | 67:40 | EGSE | Open & Close HPV1 STEPWISE to 50 Bar @ ROxTPT (stop at 30 bar and wait 30 seconds to check for leakage) | 3 | ||||||
205 | 67:40 | EGSE | Open & Close HPV1 STEPWISE to more than 50 Bar @ RHPPT and check ROxTPT 50 Bar | 3 | ||||||
206 | 67:40 | EGSE | Check if HPV1 is closed | 3 | ||||||
207 | 67:40 | OBDH | Open RDV SHORTLY, to check tightness @ RHPPT & ROxTPT (If leakages occur Abort) | 3 | ||||||
208 | 67:40 | EGSE | Open MPV1/MPV2 | 3 | ||||||
209 | 67:40 | EGSE | Open & Close MPV3 STEPWISE to 50 Bar @ OxOutPT | 3 | ||||||
210 | 67:40 | EGSE | Close MPV1/MPV2 | 3 | ||||||
211 | 67:40 | EGSE | Check & compare OxOutPT with OxInPT1 | 3 | ||||||
212 | 67:40 | EGSE | Check if RHPPT & ROxTPT more than OxInPT1, If less Open & Close HPV1 | 3 | ||||||
213 | 67:40 | EGSE | Zero OxTank Mass | 3 | ||||||
214 | 67:40 | MCC | Write down Time | 3 | ||||||
215 | 67:40 | EGSE | Open OxV1 | 3 | 04:00 | |||||
216 | 63:40 | OBDH | Open & Close RDV STEPWISE until N2O bottle empty or 25kg OxTankMass, keep temperatures RDVT and RDVET above 10<31>C and Check delta ROxTPT and OxInPT1 | 3 | 30:00:00 | |||||
217 | 33:40 | EGSE | Close OxV1 | 3 | 00:10 | |||||
218 | 33:30 | EGSE | Check if Pressure rises in OxPT1, if Pressure rises relief via OxV1 or wait for Pressure relief valve | 3 | 01:00 | |||||
219 | 32:30 | EGSE | Check & compare OxOutPT with OxInPT2 | 3 | ||||||
220 | 32:30 | EGSE | Check & compare RHPPT & ROxTPT 50 Bar and more than OxInPT2, If less Open & Close HPV1 | 3 | ||||||
221 | 32:30 | EGSE | Open OxV2 | 3 | ||||||
222 | 32:30 | OBDH | Open & Close RDV STEPWISE to 25kg OxTankMass, keep temperatures RDVT and RDVET above 10<31>C and Check delta OxTPT and OxInPT1 | 3 | 20:00 | |||||
223 | 12:30 | EGSE | Close OxV2 | 3 | 00:10 | |||||
224 | 12:20 | EGSE | Check if Pressure rises in OxPT2, if Pressure rises relief via OxV2 or wait for Pressure relief valve | 3 | 01:00 | |||||
225 | 11:20 | EGSE | Open OxDV STEPWISE until OxOutPT 0 Bar | 3 | ||||||
226 | 11:20 | OBDH | Check ROxCV for tightness @ ROxTPT | 3 | ||||||
227 | 11:20 | EGSE | Close OxDV | 3 | 01:00 | |||||
228 | 10:20 | EGSE | Write down OxTankMass | 3 | ||||||
229 | 10:20 | MCC | Provide OxTankMass and temperature readings to Wind weighting station | 3 | 00:30 | |||||
230 | 9:50 | EGSE | Confirm OxV1 & OxV2 closed | 3 | ||||||
231 | 9:50 | EGSE | Check OxOutPT 0 Bar | 3 | ||||||
232 | 9:50 | EGSE | Decouple N2O coupling | 3 | 00:20 | |||||
233 | 9:30 | MCC | Confirm End of Oxidator Fueling to OPS | 3 | 00:15 | |||||
234 | 9:15 | OBDH/TMTC | Check RF451-Link | 3 | 00:20 | |||||
235 | 8:55 | TMTC | Check GPS-lock | 3 | 00:20 | |||||
236 | 8:35 | TMTC | Check Telemega-Link | 3 | 00:20 | |||||
237 | 8:15 | MCC | HOLD | HOLD | 3 | |||||
238 | 8:15 | OPS | Align MRL to Launch Trajectory | 3 | ||||||
239 | 8:15 | MCC | Turn audio volume down | 3 | ||||||
240 | 8:15 | MCC | Turn off Confirm delay | 3 | ||||||
241 | 8:15 | MCC | Confirm MRL adjustment with OPS | 3 | ||||||
242 | 8:15 | ALL | Talk through Launch Sequence | 3 | ||||||
243 | 8:15 | AVC | Start Video Recording in Block House | 3 | ||||||
244 | 8:15 | MCC | CONTINUE AFTER HOLD | |||||||
245 | 8:15 | MCC | BEGIN Switching to Internal Power Sequence | Switch to Internal Power | 3 | |||||
246 | 8:15 | EGSE | Switch to internal Power | 3 | 00:20 | |||||
247 | 7:55 | OBDH | Confirm EPS Voltages are within limits | 3 | 00:10 | |||||
248 | 7:45 | OBDH | Confirm RF451 Transmitting | 3 | 00:05 | |||||
249 | 7:40 | OBDH/TMTC | Confirm RF451-Link | 3 | 00:20 | |||||
250 | 7:20 | TMTC | Confirm GPS-lock | 3 | 00:20 | |||||
251 | 7:00 | TMTC | Confirm Telemega-Link | 3 | 00:20 | |||||
252 | 6:40 | OBDH | Switch to PREAMRED | 3 | 00:10 | |||||
253 | 6:30 | PYL | Confirm Payload is running | 3 | 00:20 | |||||
254 | 6:10 | AVC | Confirm that videorecording @ MCC is running | 3 | 00:05 | |||||
255 | 6:05 | MCC | BEGIN SEQUENCE: High Pressure Fueling | High Pressure Fueling | 3 | |||||
256 | 6:05 | EGSE | Open & Close HPV1 STEPWISE until RHPPT 300 Bar or pressure equal to He Bottle 1 | 3 | ||||||
257 | 6:05 | EGSE | Open & Close HPV2 STEPWISE until RHPPT 300 Bar | 3 | ||||||
258 | 6:05 | EGSE | Open & close HPDV STEPWISE until HPLPT 0 Bar | 3 | ||||||
259 | 6:05 | EGSE | Confirm HPDV closed | 3 | ||||||
260 | 6:05 | OBDH/EGSE | Check for leakage & HPLPT 0 Bar & RHPPT 300 Bar | 3 | 02:00 | |||||
261 | 4:05 | OBDH | Acknowledge end of Fueling | 3 | 00:10 | |||||
262 | 3:55 | MCC | Confirm End of Fueling to OPS | 3 | 00:20 | |||||
263 | 3:35 | MCC | BEGIN SEQUENCE: Disconnecting Fueling Arm | Disconnecting Fueling Arm | 3 | 00:10 | ||||
264 | 3:25 | EGSE | Confirm HPV1 & HPV2 closed | 3 | 00:10 | |||||
265 | 3:15 | EGSE | Check HPLPT 0 Bar | 3 | 00:10 | |||||
266 | 3:05 | EGSE | Decouple Helium coupling | 3 | 00:20 | |||||
267 | 2:45 | EGSE | Confirm Helium coupling is disconnected | 3 | 00:10 | |||||
268 | 2:35 | EGSE | Move fueling arm away from rocket | 3 | 00:40 | |||||
269 | 1:55 | MCC | Confirm Fueling Arm away to OPS | 3 | 00:15 | |||||
270 | 1:40 | MCC | Prepare for Launch | 3 | 00:10 | |||||
271 | 1:30 | OBDH | Confirm ready for launch | 3 | 00:10 | |||||
272 | 1:20 | EGSE | Confirm ready for launch | 3 | 00:10 | |||||
273 | 1:10 | MCC | Set Go/No-Go System to Go | 3 | 00:10 | |||||
274 | 1:00 | MCC | Wait for Authorization for Launch | 3 | 00:00 | |||||
275 | 1:00 | MCC | BEGIN SEQUENCE: Ignition | Ignition Sequence | 4 | 00:10 | ||||
276 | 0:50 | OBDH | ARM | 4 | 00:05 | |||||
277 | 0:45 | OBDH | Confirm all status indicators green | 4 | 00:05 | |||||
278 | 0:40 | OBDH | Disconnect Ethernet | 4 | 00:30 | |||||
279 | 0:10 | EGSE | Turn on Ignition Secure | 4 | 00:07 | |||||
280 | 0:03 | EGSE | T-3: Ignition | 4 | 00:03 | |||||
281 | 0:00 | OBDH | T+0: Verify RMOxOV Open (Launched) | 4 | 00:00 | |||||
282 | 0:00 | EGSE | T+1: Turn OFF Ignition | 4 | ||||||
283 | 0:00 | EGSE | T+5: Turn OFF Ignition Secure | 4 | ||||||
284 | 0:00 | OBDH | T+20: Verify RMOxOV Closed and RMOxSV Open (Cruise) | 4 | ||||||
285 | 0:00 | OBDH | T+50: Verify RNCEV Open (Drogue) | 4 | ||||||
286 | 0:00 | OBDH | T+310: Verify Main Chute Deployed and RDV Open (Main) | 4 | ||||||
287 | 0:00 | OBDH | T+600: Verify (Landed) | 4 | ||||||
288 | 0:00 | MCC | START OF PASSIVATION (PHASE YELLOW) (Write down Time) | Passivation | 2 | |||||
289 | 0:00 | MCC | Turn audio volume up | 2 | ||||||
290 | 0:00 | TMTC | Check ROxTPT & RHPPT 1 Bar, if more: Open & Close STEPWISE RDV | 2 | ||||||
291 | 0:00 | MRL | Go to Testrig, Close N2O Bottle 1 & N2O Bottle 2 then RETURN to Block House | 2 | ||||||
292 | 0:00 | EGSE | Open OxDV | 2 | ||||||
293 | 0:00 | EGSE | Open OxV1 | 2 | ||||||
294 | 0:00 | EGSE | Check OxInPT1 & OxOutPT 0 Bar | 2 | ||||||
295 | 0:00 | EGSE | Close OxV1 | 2 | ||||||
296 | 0:00 | EGSE | Open OxV2 | 2 | ||||||
297 | 0:00 | EGSE | Check OxInPT2 & OxOutPT 0 Bar | 2 | ||||||
298 | 0:00 | EGSE | Close OxV2 | 2 | ||||||
299 | 0:00 | EGSE | Close OxDV | 2 | ||||||
300 | 0:00 | MRL | Close He Bottle 2 | 2 | ||||||
301 | 0:00 | MRL | Write down remaining Pressure of He Bottle 2 | 2 | ||||||
302 | 0:00 | EGSE | Open HPDV | 2 | ||||||
303 | 0:00 | EGSE | Open HPV2 | 2 | ||||||
304 | 0:00 | EGSE | Check pressure HPLPT & HPPT2 0 Bar | 2 | ||||||
305 | 0:00 | EGSE | Close HPV2 | 2 | ||||||
306 | 0:00 | EGSE | Close HPDV | 2 | ||||||
307 | 0:00 | MRL | Go to Testrig, confirm HPPG2 0 Bar, else return to Block House, THEN... | 2 | ||||||
308 | 0:00 | MRL | Close He Bottle 1 | 2 | ||||||
309 | 0:00 | MRL | Open ComTerm | 2 | ||||||
310 | 0:00 | MRL | Write down remaining Pressure of He Bottle 1 | 2 | ||||||
311 | 0:00 | MRL | Step back | 2 | ||||||
312 | 0:00 | EGSE | Open HPDV | 2 | ||||||
313 | 0:00 | EGSE | Open HPV1 | 2 | ||||||
314 | 0:00 | EGSE | Check pressure HPLPT & HPPT1 0 Bar | 2 | ||||||
315 | 0:00 | EGSE | Close HPV1 | 2 | ||||||
316 | 0:00 | EGSE | Close HPDV | 2 | ||||||
317 | 0:00 | EGSE | Pressure Check | 2 | ||||||
318 | 0:00 | MRL | Open MBV | 2 | ||||||
319 | 0:00 | EGSE | Check and compare pressure HPPT1 with HPPG1 | 2 | ||||||
320 | 0:00 | MRL | Close MBV | 2 | ||||||
321 | 0:00 | MRL | Take out B1 & B2 Bridges | 2 | ||||||
322 | 0:00 | MRL | Safety is ensured | 2 | ||||||
323 | 0:00 | MCC | Confirm to OPS that Safety is ensured | 1 | ||||||
324 | 0:00 | MCC | END OF PASSIVATION (PHASE GREEN) (Write down Time) | 1 | ||||||
325 | 0:00 | MCC | START DATA COLLECTION (Write down Time) | Collection | 1 | |||||
326 | 0:00 | AVC | Turn off GoPro & Camcorder & Stop Block House Video recording | 1 | ||||||
327 | 0:00 | EGSE | Copy PID.vi.tdms & save to new name | 1 | ||||||
328 | 0:00 | EGSE | Wait for buffer storage process to be finished | 1 | ||||||
329 | 0:00 | EGSE | save data files from cRIO to PC | 1 | ||||||
330 | 0:00 | AVC | End audio recording | 1 | ||||||
331 | 0:00 | MCC | END OF PROCEDURE (Write Down Time) | 1 | ||||||
332 | 0:00 | AVC | Save video & audio data on external HDD | 1 | ||||||
333 | 0:00 | MCC | Stop RT_CD.vi and save logfile to external HDD | 1 | ||||||
334 | 0:00 | MCC | PROCEDURE FINISHED | End | 1 |