procedure/AbortProcedure.csv

3.2 KiB

1vers.;v4.16;Abort Procedure;;3;;;;;
20:00;MCC;Inform OPS of Launch Abort;;3;;;;;
30:00;MCC;BEGIN:Defueling Rocket;Defueling;3;;;;;
40:00;EGSE;Confirm all valve switches are in OFF position (Except OxDV & HPDV);;3
50:00;OBDH;Confirm all valve switches are in OFF position (Except RMOxSV);;3
60:00;OBDH;Activate Heizi;;3;;;;;
70:00;MCC;Turn audio volume up;;2;;;;;
80:00;EGSE;Open & Close OxDV STEPWISE until OxOutPT 0 Bar;;3
90:00;EGSE;Open OxDV;;3
100:00;EGSE;Open MPV3;;3
110:00;EGSE;Confirm OxOutPT 0 bar;;3
120:00;EGSE;Close MPV3;;3
130:00;EGSE;Close OxDV;;3
140:00;EGSE;Open HPDV;;3
150:00;EGSE;Confirm HPLPT 0 bar;;3
160:00;EGSE;Close HPDV;;3
170:00;OBDH;Deactivate Heizi;;3
180:00;ALL;Wait for Launchpad to be clear of N2O fumes depending on OxMass before Defueling;;3;;;;;
190:00;MCC;BEGIN: ground segment passivation;GSE Passivation;3;;;;;
200:00;MCC;Announce BEGIN of Radio Silence;;3;;;;;
210:00;MRL;RETURN to Block House;;2;;;;;
220:00;EGSE;Open OxDV;;2;;;;;
230:00;EGSE;Open OxV1;;2;;;;;
240:00;EGSE;Confirm OxInPT1 & OxOutPT 0 Bar;;2;;;;;
250:00;EGSE;Close OxV1;;2;;;;;
260:00;EGSE;Open OxV2;;2;;;;;
270:00;EGSE;Confirm OxInPT2 & OxOutPT 0 Bar;;2;;;;;
280:00;EGSE;Close OxV2;;2;;;;;
290:00;EGSE;Close OxDV ;;2;;;;;
300:00;MRL;Return to Block House;;2;;;;;
310:00;EGSE;Open HPDV;;2;;;;;
320:00;EGSE;Open HPV2;;2;;;;;
330:00;EGSE;Confirm pressure HPLPT & HPPT2 0 Bar;;2;;;;;
340:00;EGSE;Close HPV2;;2;;;;;
350:00;EGSE;Close HPDV;;2;;;;;
360:00;MRL;Open ComTerm;;2;;;;;
378:15;MCC;Turn ON ComTerm step delay;;3;;;;;
380:00;MCC/MRL;Write down remaining Pressure of He Bottle 1;;2;;;;;
390:00;MRL;Step back;;2;;;;;
400:00;EGSE;Open HPDV;;2;;;;;
410:00;EGSE;Open HPV1;;2;;;;;
420:00;EGSE;Confirm pressure HPLPT & HPPT1 0 Bar;;2;;;;;
430:00;EGSE;Close HPV1;;2;;;;;
440:00;EGSE;Close HPDV;;2;;;;;
450:00;EGSE;Pressure Check;;2;;;;;
460:00;MRL;Open MBV;;2;;;;;
470:00;EGSE/ MRL;Check and compare pressure HPPT1 with HPPG1;;2;;;;;
480:00;MRL;Close MBV;;2;;;;;
490:00;MRL;Take out Bridges B1 & B2 from EGSE;;2;;;;;
500:00;MRL;Disconnect Ignition Umbilical;;1;;;;00:30;
510:00;MRL;Safety is ensured;;2;;;;;
520:00;MCC;Confirm to OPS that Safety is ensured;;1;;;;;
530:00;MCC;BEGIN SEQUENCE: Data collection;Data collection;1;;;;;
540:00;AVC;Turn off GoPro & Camcorder & Stop Block House Video recording;;1;;;;;
550:00;EGSE;Copy PID.vi.tdms & save to new name;;1;;;;;
560:00;EGSE;Wait for buffer storage process to be finished;;1;;;;;
570:00;EGSE;save data files from cRio to PC;;1;;;;;
580:00;WIND;Save data on external HDD;;1;;;;;
590:00;TMTC;Stop TMTC Vi and save data on external HDD;;1;;;;;
600:00;AVC;End audio recording;;1;;;;;
610:00;MCC;Restart ComTerm VI;;1;;;;;
620:00;AVC;Save video & audio data on external HDD;;1;;;;;
630:00;MCC;END OF PROCEDURE;;1;;;;;
640;MCC;END OF ABORT Procedure (PHASE GREEN) (Write down Time);;1