procedure/AbortProcedure.csv

3.2 KiB

1vers.v4.25Abort Procedure3mrlmccrdhtime
20:00MCCBEGIN SEQUENCE: Defueling RocketDefueling3
30:00MCCInform OPS of Launch Abort3
40:00EGSEConfirm all valve switches are in OFF position (Except OxDV & HPDV)3
50:00OBDHConfirm all valve switches are in OFF position (Except RMOxSV)3
60:00OBDHActivate Heizi3
70:00MCCTurn audio volume up3
80:00EGSEOpen & Close OxDV STEPWISE until OxOutPT 0 Bar3
90:00EGSEOpen OxDV3
100:00EGSEOpen MPV33
110:00EGSEConfirm OxOutPT 0 bar3
120:00EGSEClose MPV33
130:00EGSEClose OxDV3
140:00EGSEOpen HPDV3
150:00EGSEConfirm HPLPT 0 bar3
160:00EGSEClose HPDV3
170:00OBDHConfirm ROxTPT & RHPPT 1 Bar, if more: Open & Close stepwise RDV3
180:00OBDHDeactivate Heizi3
190:00ALLWait for Launchpad to be clear of N2O fumes depending on OxMass before Defueling3
200:00MCCBEGIN SEQUENCE: Ground support equipment passivationGSE Passivation3
210:00MCCAnnounce BEGIN of Radio Silence3
220:00MRLGo to MRL, Close N2O Bottle 1 & N2O Bottle 2, THEN...2
230:00MRLRETURN to Block House2
240:00EGSEOpen OxDV2
250:00EGSEOpen OxV12
260:00EGSEConfirm OxInPT1 & OxOutPT 0 Bar2
270:00EGSEClose OxV12
280:00EGSEOpen OxV22
290:00EGSEConfirm OxInPT2 & OxOutPT 0 Bar2
300:00EGSEClose OxV22
310:00EGSEClose OxDV 2
320:00MRLGo to MRL, confirm OxInPG1 & OxInPG2 0 Bar, else RETURN to Block House, THEN...2
330:00MRLClose He Bottle 2, THEN...2
340:00MRLWrite down remaining Pressure of He Bottle 2, THEN...2
350:00MRLReturn to Block House2
360:00EGSEOpen HPDV2
370:00EGSEOpen HPV22
380:00EGSEConfirm pressure HPLPT & HPPT2 0 Bar2
390:00EGSEClose HPV22
400:00EGSEClose HPDV2
410:00MRLGo to Testrig, confirm HPPG2 0 Bar, else return to Block House, THEN...2
420:00MRLClose He Bottle 1, THEN ...2
430:00MRLOpen ComTerm2
448:15MCCTurn ON ComTerm step delay2
450:00MCC/MRLWrite down remaining Pressure of He Bottle 12
460:00MRLStep back2
470:00EGSEOpen HPDV2
480:00EGSEOpen HPV12
490:00EGSEConfirm pressure HPLPT & HPPT1 0 Bar2
500:00EGSEClose HPV12
510:00EGSEClose HPDV2
520:00EGSEPressure Check2
530:00MRLOpen MBV2
540:00EGSE/ MRLCheck and compare pressure HPPT1 with HPPG12
550:00MRLClose MBV2
560:00MRLTake out Bridges B1 & B2 from EGSE2
570:00MRLDisconnect Ignition Umbilical200:30
580:00MRLSafety is ensured2
590:00MCCConfirm to OPS that Safety is ensured1
600:00MCCBEGIN SEQUENCE: Data collectionData collection1
610:00AVCTurn off GoPro & Camcorder & Stop Block House Video recording1
620:00EGSECopy PID.vi.tdms & save to new name1
630:00EGSEWait for buffer storage process to be finished1
640:00EGSEsave data files from cRio to PC1
650:00WINDSave data on external HDD1
660:00TMTCStop TMTC Vi and save data on external HDD1
670:00AVCEnd audio recording1
680:00MCCStop ComTerm and save logfile to external HDD, THEN...1
690:00MCCRestart ComTerm VI1
700:00AVCSave video & audio data on external HDD1
710:00MCCEND OF PROCEDUREEND1