procedure/PassivationProcedure.csv

2.1 KiB

1vers.v4.19Passivation out of sequence Procedure2
20:00MCC/MRLRecall and make sure BOTH N2O Bottles & He Bottle 2 are still closed! Else continue with Abort Procedure2
30:00MCCInform OPS of Passivation out of sequence2
40:00MRLStep Back/Leave MRL2
50:00EGSEConfirm all valve switches are in OFF position (Except OxDV & HPDV)2
60:00OBDHConfirm all valve switches are in OFF position (Except RMOxSV)2
70:00EGSEOpen & Close OxDV STEPWISE until OxOutPT 0 Bar2
80:00EGSEOpen OxDV2
90:00EGSEOpen MPV32
100:00EGSEConfirm OxOutPT 0 bar2
110:00EGSEClose MPV32
120:00EGSEOpen OxV12
130:00EGSEConfirm OxInPT1 & OxOutPT 0 Bar2
140:00EGSEClose OxV12
150:00EGSEOpen OxV22
160:00EGSEConfirm OxInPT2 & OxOutPT 0 Bar2
170:00EGSEClose OxV22
180:00EGSEClose OxDV 2
190:00EGSEOpen HPDV2
200:00EGSEConfirm HPLPT 0 bar2
210:00EGSEOpen HPV22
220:00EGSEConfirm HPLPT & HPPT2 0 bar2
230:00EGSEClose HPV22
240:00EGSEClose HPDV2
250:00MCCBEGIN:Passivation of RocketPassivation of Rocket2
260:00OBDHOpen & Close stepwise RDV until RHPPT & ROxTPT 1 Bar2
270:00OBDHConfirm RHPPT & ROxTPT 1 Bar2
280:00MRLGo to MRL2
290:00MRLRemove HP section maintenance cover2
300:00MRLOpen RMDV & Step Back, Wait until NCE-Tank is pressureless2
310:00MCCBEGIN:Passivation of GSEPassivation of GSE2
320:00MRLGo to MRL2
330:00MRLClose He Bottle 12
340:00MCC/MRLWrite down remaining Pressure of He Bottle 12
350:00MRLStep back2
360:00EGSEOpen HPDV2
370:00EGSEOpen HPV12
380:00EGSEConfirm HPLPT & HPPT1 0 Bar2
390:00EGSEClose HPV12
400:00EGSEClose HPDV2
410:00EGSEPressure Check2
420:00MRLOpen MBV2
430:00EGSE/ MRLCheck and compare pressure HPPT1 with HPPG12
440:00MRLClose MBV2
450:00MRLSafety is ensured2
460:00MCCConfirm to OPS that Safety is ensured1
470:00MCCEND OF PROCEDURE1