1.5 KiB
1.5 KiB
1 | vers. | v2.4 | Abort Procedure | 3 | |
---|---|---|---|---|---|
2 | 0 | ALL | BEGIN ABORT PROCEDURE | 3 | |
3 | 0 | EGSE | Confirm all valve switches are in OFF position (Except OxDV & HPDV) | 3 | |
4 | 0 | OBDH | Confirm all valve switches are in OFF position (Except RMOxSV) | 3 | |
5 | 0 | EGSE | Open OxDV stepwise | 3 | |
6 | 0 | EGSE | Open MPV3 | 3 | |
7 | 0 | EGSE | Check OxOutPT 0 bar | 3 | |
8 | 0 | EGSE | Close MPV3 | 3 | |
9 | 0 | EGSE | Close OxDV | 3 | |
10 | 0 | EGSE | Check OxOutPT 0 bar | 3 | |
11 | 0 | EGSE | Open HPDV | 3 | |
12 | 0 | EGSE | Check HPLPT 0 bar | 3 | |
13 | 0 | EGSE | Close HPDV | 3 | |
14 | 0 | OBDH | Check ROxTPT & RHPPT 1 Bar, if more: Open & Close stepwise RDV | 3 | |
15 | 0 | OBDH | Deactivate Heizi | 2 | |
16 | 0 | MRL | Go to MRL | 2 | |
17 | 0 | MRL | Close N2O Bottle 1 & N2O Bottle 2 | 2 | |
18 | 0 | MRL | Go to BlockHouse | 2 | |
19 | 0 | EGSE | Open OxDV | 2 | |
20 | 0 | EGSE | Open OxV1 | 2 | |
21 | 0 | EGSE | Check OxInPT1 & OxOutPT 0 Bar | 2 | |
22 | 0 | EGSE | Close OxV1 | 2 | |
23 | 0 | EGSE | Open OxV2 | 2 | |
24 | 0 | EGSE | Check OxInPT2 & OxOutPT 0 Bar | 2 | |
25 | 0 | EGSE | Close OxV2 | 2 | |
26 | 0 | EGSE | Close OxDV | 2 | |
27 | 0 | MRL | Go to MRL | 2 | |
28 | 0 | MRL | Confirm OxInPG1 & OxInPG2 0 Bar | 2 | |
29 | 0 | MRL | Close HE Bottle | 2 | |
30 | 0 | MRL | Write down remaining Pressure of HE Bottle | 2 | |
31 | 0 | MRL | Go to BlockHouse | 2 | |
32 | 0 | EGSE | Open HPDV | 2 | |
33 | 0 | EGSE | Open HPV2 | 2 | |
34 | 0 | EGSE | Check pressure HPLPT & HPPT2 0 Bar | 2 | |
35 | 0 | EGSE | Close HPV2 | 2 | |
36 | 0 | EGSE | Close HPDV | 2 | |
37 | 0 | MRL | Go to MRL | 2 | |
38 | 0 | MRL | Confirm HPPG2 0 Bar | 2 | |
39 | 0 | MRL | Close N2 Bottle | 2 | |
40 | 0 | MRL | Write down remaining Pressure of N2 Bottle | 2 | |
41 | 0 | MRL | Step back | 2 | |
42 | 0 | MRL | Open MBV | 2 | |
43 | 0 | EGSE | Check and compare pressure HPPT1 with HPPG1 | 2 | |
44 | 0 | MRL | Close MBV | 2 | |
45 | 0 | MRL | Disconnect Zündi | 2 | |
46 | 0 | MRL | Safety is ensured | 2 | |
47 | 0 | MCC | Turn off area warning light and open barrier | 1 | |
48 | 0 | MCC | END OF ABORT Procedure (PHASE GREEN) (Write down Time) | 1 |