procedure/LaunchProcedure.csv

24 KiB
Raw Blame History

1vers.v4.14Launch Procedure0MRLMCCRdHillTime per step
2147:20WINDStart wind weighting analysis1
3147:20MCCBEGIN SEQUENCE: Power on EGSEPower on EGSE1
4147:20EGSECheck CLD connection1
5147:20EGSESwitch ON CLD via Battery & check voltage (24 Volt)1
6147:20EGSESwitch ON the primary and secondary supply switches on the Control Panel101:00
7146:20EGSE @MRLSwitch ON Sup_24V_20A & check voltage (ca. 27,2 Volt)1
8146:20EGSE @MRLSwitch ON Sup_24V_10A & check voltage (ca. 27,2 Volt)1
9146:20EGSE @MRLSwitch ON Sup_12V_10A & check voltage (ca. 13,8 Volt)1
10146:20EGSE @MRLSwitch ON Bat_24V_20A & check voltage (ca. 27,9 Volt)1
11146:20EGSE @MRLSwitch ON Bat_24V_10A & check voltage (ca. 27,9 Volt)1
12146:20EGSE @MRLSwitch ON Bat_12V_10A & check voltage (ca. 13,8 Volt)1
13146:20EGSE @MRLSwitch ON Sup_24V_40A1
14146:20EGSE @MRLSwitch ON Sup_5V_10A103:00
15143:20EGSEConnect to cRio1
16143:20EGSEStart RT_VI1
17143:20EGSEOpen PID-VI and confirm it is running1
18143:20EGSERename PID-Logfile102:00
19141:20MCCBEGIN SEQUENCE: Connect Data UmbilicalConnect Data Umbilical100:30
20141:20MRLConfirm working personel is grounded1
21141:20EGSL @MRLConfirm ALL 8 Grounding bridges are inserted1
22141:20EGSL @MRLConnect Data Umbilical1
23140:50EGSETurn on EPS_BAT1
24140:50EGSETurn on EPS_EXT1
25140:50EGSE @MRLLeave EPS_BAT inserted and remove the other 7 Grounding Bridges1
26140:50EGSE @MRLInsert EPS_EXT Fuse in Power Supply Control Panel1
27140:50EGSE @MRLConfirm green LED at EPS_EXT Fuse is on1
28140:50EGSE @MRLInsert Main_Bus Fuse in Power Supply Control Panel1
29140:50EGSE @MRLConfirm LED at Main_Bus Fuse is OFF. Else Pull fuse and insert all Grounding Bridges1
30140:50EGSE @MRLSet remaining Fuses (except Payload Fuse) and check for green LED1
31140:50EGSETurn OFF EPS_BAT1
32140:50EGSE @MRLConfirm Main bus LED is on.1
33140:50EGSEStart EPS via EPS_ext1
34140:50OBDHClear SD-Card-using FileZilla FTP101:00
35139:50OBDHConnect to sbRio1
36139:50OBDHStart RT_Main1
37139:50MRLConfirm 3 beeps at OBC11
38139:50OBDHOpen RT_Sub_HMI1
39139:50OBDHConfirm Main Chute button is disabled1
40139:50EGSE @MRLInsert Payload Fuse1
41139:50EGSE @MRLConfirm green LED at Payload Fuse is on1
42139:50WINDReport on weather situation1
43139:50MCCBEGIN SEQUENCE: Connect Fueling armConnect Fueling Arm1
44139:50MRLConfirm working personel is grounded101:00
45139:50MRLConfirm PPG 0 bar1
46138:50MRLRemove Pneumatic Line from Fueling arm1
47138:50MRLMove Fueling arm to rocket1
48138:50MRLCouple Helium coupling1
49138:50MRLCouple N2O coupling1
50138:50MRLReattach Pneumatic Line to Fueling arm103:00
51135:50EGSEBEGIN SEQUENCE: EGSE sensor and actuator testEGSE sensor & actuator test1
52135:50MCCConfirm that video recording is enabled @ MCC100:10
53135:50MRLConfirm that Ignition Umbilical is disconnected1
54135:40OBDHCheck EPS hardware Voltages100:10
55135:30EGSEStart PID data recording100:10
56135:20MRLClose HPNV 1100:10
57135:20MRLClose HPNV 2100:10
58135:10EGSE/ MRLSwitch OxDV to closed & check if magnetic valve LED is on100:10
59135:00EGSE/ MRLSwitch HPDV to closed & check if magnetic valve LED is on100:10
60134:50EGSE/ MRLCheck warning lamp on HPSM100:10
61134:40MRLRemove loose equipment103:00
62131:40EGSEActivate Heizi100:10
63131:30EGSEActivate N2O_Heater 1100:10
64131:20EGSEActivate N2O_Heater 2100:10
65131:10EGSEActivate He_Heater100:10
66131:00OBDHVerify Heizi @ RDVT & RDVET100:10
67130:50EGSE/ MRLCheck Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD100:10
68130:40EGSE/ MRLCheck Water Temperatures @ OxWT1, OxWT2, HPWT2100:10
69130:30EGSEDeactivate Heizi100:10
70130:20EGSE/ MRLCheck OxV1 (CLD & RT_VI)100:10
71130:10EGSE/ MRLCheck OxV2 (CLD & RT_VI)100:10
72130:00EGSE/ MRLCheck MPV3 (CLD & RT_VI)100:10
73129:50EGSE/ MRLCheck HPV1 (CLD & RT_VI)100:10
74129:40EGSE/ MRLCheck HPV2 (CLD & RT_VI)100:10
75129:30EGSE/ MRLCheck MPV1/2 (CLD & RT_VI)100:10
76129:20EGSE/ MRLCheck RDV (CLD & RT_VI)100:10
77129:10EGSE/ MRLCheck RMOxOV (CLD & RT_VI)100:10
78129:00EGSE/ MRLCheck RMOxSV (CLD & RT_VI)100:10
79128:50OBDHActivate Heizi100:10
80128:40OBDHVerify Heizi @ RDVT & RDVET101:00
81127:40OBDH/ MRLCheck RDV100:10
82127:30OBDH/ MRLCheck RNCEV100:10
83127:20OBDH/ MRLCheck RMOxOV100:10
84127:10OBDH/ MRLCheck RMOxSV100:10
85127:00OBDH/ MRLDisable RNCEV100:10
86125:00MRLConfirm MBV closed1
87125:00EGSEConfirm that all valve switches are in OFF position (Except OxDV & HPDV)10:10
88115:00MRL/ EGSECheck loadcell by applying force to it100:20
89114:40OBDHCheck RHPPT shows atmosphere1
90114:40OBDHCheck ROxTPT shows atmosphere1
91114:40OBDHCheck RIHPT shows atmosphere1
92114:40OBDHCheck RCCPT shows atmosphere1
93114:40OBDHCheck RBaro1 shows atmosphere1
94114:40OBDHCheck RBaro2 shows atmosphere1
95114:40EGSECheck HPPT1 shows 0 bar100:20
96114:20EGSECheck HPPT2 shows 0 bar1
97114:20EGSECheck HPLPT shows 0 bar1
98114:20EGSECheck OxInPT1 shows 0 bar1
99114:20EGSECheck OxInPT2 shows 0 bar1
100114:20EGSECheck OxOutPT shows 0 bar100:20
101114:00EGSE/ MRLSwitch on N2O coupling & check if magnetic valve LED is on1
102114:00EGSE/ MRLSwitch on He coupling & check if magnetic valve LED is on1
103114:00EGSE/ MRLSwitch on swivle arm & check if magnetic valve LED is on1
104114:00EGSESwitch off swivel arm & He coupling & N2O coupling101:00
105114:00MCCBEGIN SEQUENCE: Ignition signal TestIgnition signal Test101:00
106113:00MRLConfirm that Ignition Umbilical is disconnected1
107113:00MRLConnect Ignition test receptical1
108113:00EGSE @MRLPlug in Bridges B1 and B21
109113:00MRLConfirm Soundsignal from Ignition Umbilical1
110113:00EGSETurn on Ignition Secure Switch1
111113:00EGSE/ OBDHTurn on Ignition Switch for 2 Second & Confirm ignition signal received at sbRio & cRio1
112113:00EGSEConfirm that Ignition Switch is switched OFF and secured1
113113:00EGSETurn off Ignition Secure Switch1
114113:00EGSE @MRLRemove Bridges B1 and B21
115113:00MRLRemove Ignition test receptical103:00
116110:00MCCBEGIN SEQUENCE: Ground segment pressure test (PHASE YELLOW) GSE Pressure Test1LuF, AlS, LeD: 1x Helm, 3x Ear protectorsChB, FiH, JuL, LiA, MiS
117130:50EGSE/ MRLCheck Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD100:10
118130:40EGSE/ MRLCheck Water Temperatures @ OxWT1, OxWT2, HPWT2100:10
119110:00MRLConfirm that all hatches are closed101:00
120109:00MRLConfirm He bottle 1 connector is attached1
121109:00MRLConfirm He bottle 2 connector is attached1
122109:00MRLConfirm N2O bottle 1 connector is attached1
123109:00MRLConfirm N2O bottle 2 connector is attached1
124109:00MRLConfirm hose between HPSM & N2OSM is connected on both ends1
125109:00MRLConfirm hose between HPSM & Flight Segment is connected on both ends1
126109:00MRLConfirm hose between N2OSM & Flight Segment is connected on both ends1
127109:00MRLConfirm pneumatic hose is connected on both ends102:00
128107:00MRLPut on safety equipment2
129107:00MRLConfirm MBV is closed2
130107:00MRLConfirm HPNV1 is closed2
131107:00MRLConfirm HPNV2 is closed2
132107:00MRLTake positions to open He Bottle 12
133107:00EGSEConfirm HPV1 is closed2
134107:00EGSEConfirm MPV1/2 is closed2
135107:00MRLOpen He Bottle 1201:00
136106:00MRLCheck & compare pressure HPPT1 with HPPG1 (max 300 bar)2
137106:00MRLCheck Gastech Silver HPPR1 (max 300 to 50 bar)2
138106:00MRLCheck Harris PPR (50 to 8 bar)2
139106:00MRLCheck pneumatic PPG (8 bar)2
140106:00MRLStep back201:00
141105:00EGSE/ MRLOpen & Close HPV1 SHORTLY & Check HPPT12
142105:00EGSECheck HPPT1 300 Bar2
143105:00EGSEConfirm HPLPT 0 Bar2
144105:00EGSE/ MRLOpen & Close HPV2 SHORTLY & Confirm HPPT2 0 bar2
145105:00EGSE/ MRLOpen & Close HPDV SHORTLY & Confirm HPLPT 0 bar2
146105:00EGSE/ MRLOpen & Close OxV1 SHORTLY2
147105:00EGSE/ MRLOpen & Close OxV2 SHORTLY2
148105:00EGSE/ MRLOpen & Close OxDV SHORTLY2
149105:00EGSE/ MRLOpen & Close MPV3 SHORTLY2
15000:00EGSEOpen HPV12
15100:00EGSEClose HPV12
15200:00EGSEOpen HPDV & confirm HPLPT 0 Bar2
15300:00EGSEOpen HPV2 & confirm HPPT2 0 Bar2
15400:00EGSEClose HPV22
15500:00EGSEClose HPDV2
15687:10EGSEOpen & Close STEPWISE MPV1/2 to 50 Bar @ OxInPT1 & OxInPT22
15787:10EGSEConfirm MPV1/2 closed2
15887:10EGSEOpen OxDV2
15987:10EGSEOpen & Close STEPWISE MPV3 to 0 Bar @OxOutPT2
16087:10EGSEConfirm MPV3 closed2
16187:10EGSEOpen & Close STEPWISE OxV1 to 0 Bar @OxInPT12
16287:10EGSEOpen & Close STEPWISE OxV2 to 0 Bar @OxInPT22
16387:10EGSEConfirm OxOutPT 0 Bar2
16487:10EGSEClose OxDV2
165105:00EGSEConfirm HPLPT & OxOutPT 0 Bar201:30
166103:30EGSEDecouple N2O coupling2
167103:30EGSEDecouple Helium coupling200:20
168103:10EGSEMove arm away from rocket2
169103:10EGSEMove arm to rocket201:00
170102:10MRLClose He Bottle 1 and check HPSM for leakage (If leakage occurs continue with Passivation Procedure)201:00
171101:10MRLOpen MBV2
172101:10EGSE/ MRLCheck and compare pressure HPPT1 with HPPG1 0 Bar2
173101:10MRLClose MBV200:30
174100:40MRLOpen RMDV & relief pressure2
175100:40MRLClose RMDV2
176100:40MRLSafety is ensured2
177100:40MCCEGSE @MRL to MRL1
178100:40EGSESwitch OFF N20 coupling1
179100:40EGSESwitch OFF He coupling1
180100:40MRLConfirm working personel is grounded101:00
181100:40MRLConfirm PPG 0 Bar100:20
182100:40MRLRelease Pneumatic lines of couplings100:20
183100:20EGSEConfirm Fueling arm is switched OFF1
184100:20EGSEConfirm OxOutPT and HPLPT 0 bar1
185100:20MRLCouple He coupling100:30
18699:50MRLCouple N2O coupling100:30
18799:50MRLConfirm He coupling is connected properly1
18899:50MRLConfirm N2O coupling is connected properly1
189130:50EGSE/ MRLCheck Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD100:10
190130:40EGSE/ MRLCheck Water Temperatures @ OxWT1, OxWT2, HPWT2100:10
19199:20MRLHOLDHOLD1
19299:20MCCCONTINUE AFTER HOLD
193130:50EGSE/ MRLCheck Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD100:10
194130:40EGSE/ MRLCheck Water Temperatures @ OxWT1, OxWT2, HPWT2100:10
19599:20MRLBEGIN SEQUENCE: Prime RocketPrime Rocket1
19699:20EGSETurn ON EPS_BAT101:00
19799:20MRLConfirm working personel is grounded101:00
19899:20MRLConfirm all spring retracted hatches are moving freely1
19998:50MRLTurn on GoPro Camera at end of Launch Rail100:20
20099:20MRLConnect Ignition Umbilical100:30
20198:30MRLInsert all EPS Bridges103:00
20295:30MRLConfirm Bridge Hatch is Secured100:20
20395:10EGSE @MRLreturn to MCC1
20495:10OPSElevate MRL to 90 degrees105:00
20589:40EGSEZero OxTank Mass101:00
20688:40MCCBEGIN SEQUENCE: Fueling Preparations (PHASE YELLOW)Fueling Preparations2
207130:50EGSE/ MRLCheck Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD100:10
208130:40EGSE/ MRLCheck Water Temperatures @ OxWT1, OxWT2, HPWT2100:10
209127:40OBDH!!!Check RDV100:10
210127:30OBDH!!!Check RNCEV100:10
211127:20OBDH!!!Check RMOxOV100:10
212127:10OBDH!!!Check RMOxSV100:10
213127:00OBDH!!!Disable RNCEV100:10
21488:40MRLPut on safety equipment200:30
21510:10MRLConfirm HPNV1 is Open2
21610:10MRLConfirm HPNV2 is Closed2
21788:10MRLOpen He Bottle 1201:00
21887:10MRLStep back2
21900:00EGSEOpen HPV12
22000:00EGSEClose HPV12
22100:00EGSEOpen HPDV & Confirm HPLPT 0 Bar2
22200:00EGSEConfirm HPV1 is closed2
22300:00EGSEConfirm HPV2 is closed2
22410:10MRLOpen HPNV2 1/8 Rev2
22500:00EGSEClose HPDV2
22687:10EGSEOpen & Close STEPWISE MPV1/2 to 50 Bar @ OxInPT1 & OxInPT22
22787:10EGSE/ MRLCheck & compare OxInPT1 with OxInPG1 based on Bottle temperature (max 50 bar)2
22887:10EGSE/ MRLCheck & compare pressure OxInPT2 with OxInPG2 based on Bottle temperature (max 50 bar)2
22987:10EGSE/ MRLCheck Temperature of N2O Bottle 1 @OxT1 & OxWT1 (max 22C)2
23087:10EGSE/ MRLCheck Temperature of N2O Bottle 2 @OxT2 & OxWT2 (max 22C)201:30
23185:40MRLOpen He Bottle 22
23285:40EGSE/ MRLCheck & compare pressure HPPT2 with HPPG2 (max 315 bar)201:00
23384:40ALL/ MRLCAUTION!2
23484:40MRLOpen N2O Bottle 12
23584:40MRL/ EGSECheck & compare pressure OxInPT 1 with OxInPG 1 (max 50 bar)202:00
23682:40MRLOpen N2O Bottle 22
23782:40MRL/ EGSECheck & compare pressure OxInPT 2 with OxInPG 2 (max 50 bar)202:00
23880:40MRLInsert Ignition Bridges B1 and B2 into EGSE202:00
23978:40MRLConfirm Soundsignal from Ignition Umbilical2
24078:40MRLClose ComTerm & Go to Block House2
24178:40MCCTurn OFF MRL confirm lock2
24278:40ALLInform OPS to clear Launch Pad (Tel.: [!!!])22:00
243147:20WINDStart wind weighting analysis1
244130:50EGSE/ MRLCheck Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD100:10
245130:40EGSE/ MRLCheck Water Temperatures @ OxWT1, OxWT2, HPWT2100:10
24668:40MCCHOLDHOLD2
24768:40KLPStart Camera Karsten Lapp<70>hn2
24868:40MCCCONTINUE AFTER HOLD2
249130:50EGSE/ MRLCheck Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD100:10
250130:40EGSE/ MRLCheck Water Temperatures @ OxWT1, OxWT2, HPWT2100:10
251130:40EGSEConfirm storage capacity of CRio is greater than 300MB100:10
252127:00OBDHConfirm RNCEV is disabled100:10
25368:40MCCBEGIN SEQUENCE Ox Fueling (PHASE RED)Ox Fueling (PHASE RED)3
25468:50WINDReport on weather situation1
25568:40MCCAnnounce end of Radio Silence3
25668:40EGSETurn OFF EPS_BAT3
257126:50OBDH/ TMTCConfirm RF451-Link100:20
258126:30TMTCConfirm GPS-lock100:20
259126:10TMTCConfirm Telemega-Link100:20
260125:50OBDHTest Connection to STX3100:20
261125:30OBDHConfirm that STX3 Packages are received by email100:30
262125:30AVCTurn on main TMTC screen100:30
263125:30MCCRequest Permission to begin fueling from OPS103:00
26468:40OBDHAcknowledge start of Fueling301:00
26567:40EGSEOpen & Close HPV1 STEPWISE to 50 Bar @ ROxTPT (stop every 10 bar & check ROxTBT & ROxTTT (approx. ambiente temp)3
26667:40EGSEConfirm OxOutPT 0 Bar to check ROxCV tightness3
26767:40EGSEOpen & Close HPV1 STEPWISE to more than 50 Bar @ RHPPT and confirm ROxTPT 50 Bar3
26867:40EGSEConfirm HPV1 is closed3
26967:40OBDHOpen RDV SHORTLY, to check tightness @ RHPPT & ROxTPT (If leakages occur continue with Abort Procedure)3
27067:40EGSEOpen MPV1/23
27167:40EGSEOpen & Close MPV3 STEPWISE to 50 Bar @ OxOutPT3
27267:40EGSEClose MPV1/23
27367:40EGSECheck & compare OxOutPT with OxInPT13
27467:40EGSECheck if RHPPT & ROxTPT more than OxInPT1, If less Open & Close HPV13
27567:40EGSEZero OxTank Mass3
27667:40MCCWrite down Time3
27767:40EGSEOpen OxV1304:00
27863:40OBDHOpen & Close RDV STEPWISE until N2O bottle empty or 25kg OxTankMass, keep temperatures RDVT and RDVET above 10<31>C and Check delta ROxTPT and OxInPT1330:00
27933:40EGSEVerify Bottle Temperatures @ OxT1, OxT2, HPT2100:10
28033:40EGSEVerify Water Temperatures @ Ox@T1, OxWT2, HPWT2100:10
28133:40EGSEClose OxV1300:10
28233:30EGSECheck if Pressure rises in OxPT1, if Pressure rises relief via OxV1 or wait for Pressure relief valve301:00
28332:30EGSECheck & compare OxOutPT with OxInPT23
28432:30EGSECheck & compare RHPPT & ROxTPT 50 Bar and more than OxInPT2, If less Open & Close HPV13
28532:30EGSEOpen OxV2 3
28632:30OBDHOpen & Close RDV STEPWISE to 25kg OxTankMass, keep temperatures RDVT and RDVET above 10<31>C and Check delta OxTPT and OxInPT1320:00
28712:30EGSEClose OxV2 300:10
28812:20EGSECheck if Pressure rises in OxPT2, if Pressure rises relief via OxV2 or wait for Pressure relief valve301:00
28911:20EGSEOpen OxDV STEPWISE until OxOutPT 0 Bar3
29011:20OBDHCheck ROxCV for tightness @ ROxTPT3
29111:20EGSEClose OxDV301:00
29210:20EGSEWrite down OxTankMass3
29333:40EGSEVerify He Bottle 2 Temperature @HPT2 & @HPWT2 (turn ON He_Heater if necessary) 100:10
29410:20MCCProvide OxTankMass and temperature readings to Wind weighting station300:30
2959:50EGSEConfirm OxV1 & OxV2 closed3
2969:50EGSEConfirm OxOutPT 0 Bar3
2979:50EGSEDecouple N2O coupling300:20
2989:30MCCConfirm End of Oxidator Fueling to OPS300:15
2999:20WINDStart wind weighting analysis1
3009:15OBDH/ TMTCCheck RF451-Link300:20
3018:55TMTCCheck GPS-lock300:20
3028:35TMTCCheck Telemega-Link300:20
30333:40EGSEVerify He Bottle 2 Temperature @HPT2 & @HPWT2 (turn ON/OFF He_Heater if necessary) 100:10
3048:15MCCHOLD (Last possible scheduled HOLD)HOLD3
3058:15OPSAlign MRL to Launch Trajectory3
3068:15MCCTurn audio volume down3
3078:15MCCTurn OFF ComTerm step delay3
3088:15ALLTalk through Ignition Sequence3
3098:15MCCWait for OPS to confirm final MRL adjustment3
3108:15WINDReport on weather situation1
3118:15MCCCONTINUE AFTER HOLD
3128:15AVCStart Video recording in Block House3
3138:15EGSEVerify He Bottle 2 Temperature @HPT2 & @HPWT2 (turn ON/OFF He_Heater if necessary) 100:10
3148:15MCCBEGIN SEQUENCE: Switching to Internal Power SequenceSwitch to Internal Power3
3158:15EGSETurn OFF EPS_Ext (Switch to internal Power)300:20
3167:55OBDHConfirm EPS Voltages are within limits300:10
3177:45OBDHConfirm RF451 Transmitting300:05
3187:40OBDH/ TMTCConfirm RF451-Link300:20
3197:20TMTCConfirm GPS-lock300:20
3207:00TMTCConfirm Telemega-Link300:20
3216:40OBDHSwitch to PREARMED300:10
3226:30PYLConfirm Payload is running300:20
3236:30PYLConfirm BlackBox2 is ready for launch3
3246:10AVCConfirm that videorecording @ MCC is running300:05
3256:05MCCBEGIN SEQUENCE: High Pressure FuelingHigh Pressure Fueling3
32633:40EGSEVerify He Bottle 2 Temperature @HPT2 & @HPWT2 (turn ON/OFF He_Heater if necessary) 100:10
3276:05EGSEOpen & Close HPV1 STEPWISE until RHPPT 300 Bar or pressure equal to He Bottle 13
3286:05EGSEOpen & Close HPV2 STEPWISE until RHPPT 300 Bar 3
3296:05EGSEOpen & close HPDV STEPWISE until HPLPT 0 Bar 3
3306:05EGSEConfirm HPDV closed3
3316:05OBDH/ EGSECheck for leakage & HPLPT 0 Bar & RHPPT 300 Bar 302:00
3326:05EGSETurn OFF He_Heater3
3334:05OBDHAcknowledge end of Fueling300:10
3343:55MCCConfirm End of Fueling to OPS300:20
3353:35MCCBEGIN SEQUENCE: Disconnecting Fueling ArmDisconnecting Fueling Arm300:10
3363:25EGSEConfirm HPV1 & HPV2 closed300:10
3373:15EGSEConfirm HPLPT 0 Bar 300:10
3383:05EGSEDecouple Helium coupling300:20
3392:45EGSEConfirm Helium coupling is disconnected300:10
3402:35EGSEMove fueling arm away from rocket300:40
3411:55MCCConfirm Fueling Arm away to OPS300:15
3421:40MCCPrepare for Launch300:10
3431:30OBDHConfirm ready for launch300:10
3441:20EGSEConfirm ready for launch300:10
3451:10MCCSet Go/No-Go System to Go300:10
3461:00MCCWait for Authorization for Launch300:00
3471:00MCCBEGIN SEQUENCE: IgnitionIgnition Sequence400:10
3480:50OBDHT-50 ARM400:05
3490:40OBDHT-40 Confirm all status indicators green400:05
3500:30OBDHT-30 Disconnect from sbRio400:30
3510:10EGSET-10 Turn on Ignition Secure400:07
3520:03EGSET-3: Ignition400:03
3530:00OBDHT+0: Verify RMOxOV Open (Launched)400:00
3540:00EGSET+1: Turn OFF Ignition4
3550:00EGSET+5: Turn OFF Ignition Secure4
3560:00OBDHT+20: Verify RMOxOV Closed and RMOxSV Open (Cruise)4
3570:00OBDHT+50: Verify RNCEV Open (Drogue)4
3580:00OBDHT+310: Verify Main Chute Deployed and RDV Open (Main)4
3590:00OBDHT+600: Verify (Landed)4
3600:00MCCBEGIN SEQUENCE: PASSIVATION (PHASE YELLOW) (Write down Time)Passivation2
36168:40MCCAnnounce BEGIN of Radio Silence3
3620:00MCCTurn audio volume up2
3630:00MRLGo to MRL, Close N2O Bottle 1 & N2O Bottle 2, THEN... RETURN to Block House2
3640:00MRLRETURN to Block House2
3650:00EGSEOpen OxDV2
3660:00EGSEOpen OxV12
3670:00EGSEConfirm OxInPT1 & OxOutPT 0 Bar2
3680:00EGSEClose OxV12
3690:00EGSEOpen OxV22
3700:00EGSEConfirm OxInPT2 & OxOutPT 0 Bar2
3710:00EGSEClose OxV22
3720:00EGSEClose OxDV 2
3730:00MRLClose He Bottle 2, THEN...2
3740:00MRLWrite down remaining Pressure of He Bottle 2, THEN...2
3750:00MRLReturn to Block House2
3760:00EGSEOpen HPDV2
3770:00EGSEOpen HPV22
3780:00EGSEConfirm pressure HPLPT & HPPT2 0 Bar2
3790:00EGSEClose HPV22
3800:00EGSEClose HPDV2
3810:00MRLGo to Testrig, confirm HPPG2 0 Bar, else return to Block House, THEN...2
3820:00MRLClose He Bottle 1, THEN ...2
3830:00MRLOpen ComTerm2
3840:00MCCTurn on MRL lock2
3850:00MRLWrite down remaining Pressure of He Bottle 12
3860:00MRLStep back2
3870:00EGSEOpen HPDV2
3880:00EGSEOpen HPV12
3890:00EGSEConfirm pressure HPLPT & HPPT1 0 Bar2
3900:00EGSEClose HPV12
3910:00EGSEClose HPDV2
3920:00EGSEPressure Check2
3930:00MRLOpen MBV2
3940:00EGSE/ MRLCheck and compare pressure HPPT1 with HPPG12
3950:00MRLClose MBV2
3960:00MRLTake out B1 & B2 Bridges2
3970:00MRLSafety is ensured2
3980:00MCCConfirm to OPS that Safety is ensured1
3990:00MCCBEGIN SEQUENCE: Data collectionData collection1
4000:00AVCTurn off GoPro & Camcorder & Stop Block House Video recording1
4010:00EGSECopy PID.vi.tdms & save to new name1
4020:00EGSEWait for buffer storage process to be finished1
4030:00EGSEsave data files from cRio to PC1
4040:00WINDSave data on external HDD1
4050:00TMTCStop TMTC Vi and save data on external HDD1
4060:00AVCEnd audio recording1
4070:00MCCStop ComTerm and save logfile to external HDD, THEN...1
4080:00MCCRestart ComTerm VI1
4090:00AVCSave video & audio data on external HDD1
4100:00MCCEND OF PROCEDURE1