procedure/AbortProcedure.csv

1.5 KiB

1vers.v2.4Abort Procedure3
20ALLBEGIN ABORT PROCEDURE3
30EGSEConfirm all valve switches are in OFF position (Except OxDV & HPDV)3
40OBDHConfirm all valve switches are in OFF position (Except RMOxSV)3
50EGSEOpen OxDV stepwise3
60EGSEOpen MPV33
70EGSECheck OxOutPT 0 bar3
80EGSEClose MPV33
90EGSEClose OxDV3
100EGSECheck OxOutPT 0 bar3
110EGSEOpen HPDV3
120EGSECheck HPLPT 0 bar3
130EGSEClose HPDV3
140OBDHCheck ROxTPT & RHPPT 1 Bar, if more: Open & Close stepwise RDV3
150OBDHDeactivate Heizi2
160MRLGo to MRL2
170MRLClose N2O Bottle 1 & N2O Bottle 22
180MRLGo to BlockHouse2
190EGSEOpen OxDV2
200EGSEOpen OxV12
210EGSECheck OxInPT1 & OxOutPT 0 Bar2
220EGSEClose OxV12
230EGSEOpen OxV22
240EGSECheck OxInPT2 & OxOutPT 0 Bar2
250EGSEClose OxV22
260EGSEClose OxDV 2
270MRLGo to MRL2
280MRLConfirm OxInPG1 & OxInPG2 0 Bar2
290MRLClose HE Bottle2
300MRLWrite down remaining Pressure of HE Bottle2
310MRLGo to BlockHouse2
320EGSEOpen HPDV2
330EGSEOpen HPV22
340EGSECheck pressure HPLPT & HPPT2 0 Bar2
350EGSEClose HPV22
360EGSEClose HPDV2
370MRLGo to MRL2
380MRLConfirm HPPG2 0 Bar2
390MRLClose N2 Bottle2
400MRLWrite down remaining Pressure of N2 Bottle2
410MRLStep back2
420MRLOpen MBV2
430EGSECheck and compare pressure HPPT1 with HPPG12
440MRLClose MBV2
450MRLDisconnect Zündi2
460MRLSafety is ensured2
470MCCTurn off area warning light and open barrier1
480MCCEND OF ABORT Procedure (PHASE GREEN) (Write down Time)1