changed Spaces in stations for better line breaking

This commit is contained in:
Finn 2020-06-03 11:17:01 +02:00
parent 585dd96d6b
commit 71a3e060d6
1 changed files with 73 additions and 73 deletions

View File

@ -1,17 +1,17 @@
vers.;v4.10;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
vers.;v4.13;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
147:20;WIND;Start wind weighting analysis;;1;;;;;
147:20;MCC;BEGIN SEQUENCE: Power on EGSE;Power on EGSE;1;;;;;
147:20;EGSE;Check CLD connection;;1;;;;;
147:20;EGSE;Switch ON CLD via Battery & check voltage (24 Volt);;1;;;;;
147:20;EGSE;Switch ON the primary and secondary supply switches on the Control Panel;;1;;;;01:00;
146:20;EGSE@MRL;Switch ON Sup_24V_20A & check voltage (ca. 27,2 Volt);;1;;;;;
146:20;EGSE@MRL;Switch ON Sup_24V_10A & check voltage (ca. 27,2 Volt);;1;;;;;
146:20;EGSE@MRL;Switch ON Sup_12V_10A & check voltage (ca. 13,8 Volt);;1;;;;;
146:20;EGSE@MRL;Switch ON Bat_24V_20A & check voltage (ca. 27,9 Volt);;1;;;;;
146:20;EGSE@MRL;Switch ON Bat_24V_10A & check voltage (ca. 27,9 Volt);;1;;;;;
146:20;EGSE@MRL;Switch ON Bat_12V_10A & check voltage (ca. 13,8 Volt);;1;;;;;
146:20;EGSE@MRL;Switch ON Sup_24V_40A;;1;;;;;
146:20;EGSE@MRL;Switch ON Sup_5V_10A;;1;;;;03:00;
146:20;EGSE @MRL;Switch ON Sup_24V_20A & check voltage (ca. 27,2 Volt);;1;;;;;
146:20;EGSE @MRL;Switch ON Sup_24V_10A & check voltage (ca. 27,2 Volt);;1;;;;;
146:20;EGSE @MRL;Switch ON Sup_12V_10A & check voltage (ca. 13,8 Volt);;1;;;;;
146:20;EGSE @MRL;Switch ON Bat_24V_20A & check voltage (ca. 27,9 Volt);;1;;;;;
146:20;EGSE @MRL;Switch ON Bat_24V_10A & check voltage (ca. 27,9 Volt);;1;;;;;
146:20;EGSE @MRL;Switch ON Bat_12V_10A & check voltage (ca. 13,8 Volt);;1;;;;;
146:20;EGSE @MRL;Switch ON Sup_24V_40A;;1;;;;;
146:20;EGSE @MRL;Switch ON Sup_5V_10A;;1;;;;03:00;
143:20;EGSE;Connect to cRio;;1;;;;;
130:40;EGSE;Confirm storage capacity of cRio is greater than [!!!];;1;;;;00:10;
143:20;EGSE;Start RT_VI;;1;;;;;
@ -19,18 +19,18 @@ vers.;v4.10;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
143:20;EGSE;Rename PID-Logfile;;1;;;;02:00;
141:20;MCC;BEGIN SEQUENCE: Connect Data Umbilical;Connect Data Umbilical;1;;;;00:30;
141:20;MRL;Confirm working personel is grounded;;1;;;;;
141:20;EGSL@MRL;Confirm ALL 8 Grounding bridges are inserted;;1;;;;;
141:20;EGSL@MRL;Connect Data Umbilical;;1;;;;;
141:20;EGSL @MRL;Confirm ALL 8 Grounding bridges are inserted;;1;;;;;
141:20;EGSL @MRL;Connect Data Umbilical;;1;;;;;
140:50;EGSE;Turn on EPS_BAT;;1;;;;;
140:50;EGSE;Turn on EPS_EXT;;1;;;;;
140:50;EGSE@MRL;Leave EPS_BAT inserted and remove the other 7 Grounding Bridges;;1;;;;;
140:50;EGSE@MRL;Insert EPS_EXT Fuse in Power Supply Control Panel;;1;;;;;
140:50;EGSE@MRL;Confirm green LED at EPS_EXT Fuse is on;;1;;;;;
140:50;EGSE@MRL;Insert Main_Bus Fuse in Power Supply Control Panel;;1;;;;;
140:50;EGSE@MRL;Confirm LED at Main_Bus Fuse is OFF. Else Pull fuse and insert all Grounding Bridges;;1;;;;;
140:50;EGSE@MRL;Set remaining Fuses (except Payload Fuse) and check for green LED;;1;;;;;
140:50;EGSE @MRL;Leave EPS_BAT inserted and remove the other 7 Grounding Bridges;;1;;;;;
140:50;EGSE @MRL;Insert EPS_EXT Fuse in Power Supply Control Panel;;1;;;;;
140:50;EGSE @MRL;Confirm green LED at EPS_EXT Fuse is on;;1;;;;;
140:50;EGSE @MRL;Insert Main_Bus Fuse in Power Supply Control Panel;;1;;;;;
140:50;EGSE @MRL;Confirm LED at Main_Bus Fuse is OFF. Else Pull fuse and insert all Grounding Bridges;;1;;;;;
140:50;EGSE @MRL;Set remaining Fuses (except Payload Fuse) and check for green LED;;1;;;;;
140:50;EGSE;Turn OFF EPS_BAT;;1;;;;;
140:50;EGSE@MRL;Confirm Main bus LED is on.;;1;;;;;
140:50;EGSE @MRL;Confirm Main bus LED is on.;;1;;;;;
140:50;EGSE;Start EPS via EPS_ext;;1;;;;;
140:50;OBDH;Clear SD-Card-using FileZilla FTP;;1;;;;01:00;
139:50;OBDH;Connect to sbRio;;1;;;;;
@ -38,8 +38,8 @@ vers.;v4.10;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
139:50;MRL;Confirm 3 beeps at OBC1;;1;;;;;
139:50;OBDH;Open RT_Sub_HMI;;1;;;;;
139:50;OBDH;Confirm Main Chute button is disabled;;1;;;;;
139:50;EGSE@MRL;Insert Payload Fuse;;1;;;;;
139:50;EGSE@MRL;Confirm green LED at Payload Fuse is on;;1;;;;;
139:50;EGSE @MRL;Insert Payload Fuse;;1;;;;;
139:50;EGSE @MRL;Confirm green LED at Payload Fuse is on;;1;;;;;
139:50;WIND;Report on weather situation;;1;;;;;
139:50;MCC;BEGIN SEQUENCE: Connect Fueling arm;Connect Fueling Arm;1;;;;;
139:50;MRL;Confirm working personel is grounded;;1;;;;01:00;
@ -56,17 +56,17 @@ vers.;v4.10;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
135:30;EGSE;Start PID data recording;;1;;;;00:10;
135:20;MRL;Close HPNV 1;;1;;;;00:10;
135:20;MRL;Close HPNV 2;;1;;;;00:10;
135:10;EGSE/MRL;Switch OxDV to closed & check if magnetic valve LED is on;;1;;;;00:10;
135:00;EGSE/MRL;Switch HPDV to closed & check if magnetic valve LED is on;;1;;;;00:10;
134:50;EGSE/MRL;Check warning lamp on HPSM;;1;;;;00:10;
135:10;EGSE/ MRL;Switch OxDV to closed & check if magnetic valve LED is on;;1;;;;00:10;
135:00;EGSE/ MRL;Switch HPDV to closed & check if magnetic valve LED is on;;1;;;;00:10;
134:50;EGSE/ MRL;Check warning lamp on HPSM;;1;;;;00:10;
134:40;MRL;Remove loose equipment;;1;;;;03:00;
131:40;EGSE;Activate Heizi;;1;;;;00:10;
131:30;EGSE;Activate N2O_Heater 1;;1;;;;00:10;
131:20;EGSE;Activate N2O_Heater 2;;1;;;;00:10;
131:10;EGSE;Activate He_Heater;;1;;;;00:10;
131:00;OBDH;Verify Heizi @ RDVT & RDVET;;1;;;;00:10;
130:50;EGSE/MRL;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;;1;;;;00:10;
130:40;EGSE/MRL;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;1;;;;00:10;
130:50;EGSE/ MRL;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;;1;;;;00:10;
130:40;EGSE/ MRL;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;1;;;;00:10;
130:30;EGSE;Deactivate Heizi;;1;;;;00:10;
130:20;EGSE;Check OxV1 (CLD & RT_VI);;1;;;;00:10;
130:10;EGSE;Check OxV2 (CLD & RT_VI);;1;;;;00:10;
@ -86,7 +86,7 @@ vers.;v4.10;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
127:00;OBDH;Confirm RNCEV is disabled;;1;;;;00:10;
125:00;MRL;Confirm MBV closed;;1;;;;;
125:00;EGSE;Confirm that all valve switches are in OFF position (Except OxDV & HPDV);;1;;;;0:10;
115:00;MRL/EGSE;Check loadcell by applying force to it;;1;;;;00:20;
115:00;MRL/ EGSE;Check loadcell by applying force to it;;1;;;;00:20;
114:40;OBDH;Check RHPPT shows atmosphere;;1;;;;;
114:40;OBDH;Check ROxTPT shows atmosphere;;1;;;;;
114:40;OBDH;Check RIHPT shows atmosphere;;1;;;;;
@ -99,24 +99,24 @@ vers.;v4.10;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
114:20;EGSE;Check OxInPT1 shows 0 bar;;1;;;;;
114:20;EGSE;Check OxInPT2 shows 0 bar;;1;;;;;
114:20;EGSE;Check OxOutPT shows 0 bar;;1;;;;00:20;
114:00;EGSE/MRL;Switch on N2O coupling & check if magnetic valve LED is on;;1;;;;;
114:00;EGSE/MRL;Switch on He coupling & check if magnetic valve LED is on;;1;;;;;
114:00;EGSE/MRL;Switch on swivle arm & check if magnetic valve LED is on;;1;;;;;
114:00;EGSE/ MRL;Switch on N2O coupling & check if magnetic valve LED is on;;1;;;;;
114:00;EGSE/ MRL;Switch on He coupling & check if magnetic valve LED is on;;1;;;;;
114:00;EGSE/ MRL;Switch on swivle arm & check if magnetic valve LED is on;;1;;;;;
114:00;EGSE;Switch off swivel arm & He coupling & N2O coupling;;1;;;;01:00;
114:00;MCC;BEGIN SEQUENCE: Ignition signal Test;Ignition signal Test;1;;;;01:00;
113:00;MRL;Confirm that Ignition Umbilical is disconnected;;1;;;;;
113:00;MRL;Connect Ignition test receptical;;1;;;;;
113:00;EGSE@MRL;Plug in Bridges B1 and B2;;1;;;;;
113:00;EGSE @MRL;Plug in Bridges B1 and B2;;1;;;;;
113:00;MRL;Confirm Soundsignal from Ignition Umbilical;;1;;;;;
113:00;EGSE;Turn on Ignition Secure Switch;;1;;;;;
113:00;EGSE/OBDH;Turn on Ignition Switch for 2 Second & Confirm ignition signal received at sbRio & cRio;;1;;;;;
113:00;EGSE/ OBDH;Turn on Ignition Switch for 2 Second & Confirm ignition signal received at sbRio & cRio;;1;;;;;
113:00;EGSE;Confirm that Ignition Switch is switched OFF and secured;;1;;;;;
113:00;EGSE;Turn off Ignition Secure Switch;;1;;;;;
113:00;EGSE@MRL;Remove Bridges B1 and B2;;1;;;;;
113:00;EGSE @MRL;Remove Bridges B1 and B2;;1;;;;;
113:00;MRL;Remove Ignition test receptical;;1;;;;03:00;
110:00;MCC;BEGIN SEQUENCE: Ground segment pressure test (PHASE YELLOW) ;GSE Pressure Test;1;;;;;
130:50;EGSE/MRL;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;;1;;;;00:10;
130:40;EGSE/MRL;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;1;;;;00:10;
110:00;MCC;BEGIN SEQUENCE: Ground segment pressure test (PHASE YELLOW) ;GSE Pressure Test;1;LuF, AlS, LeD: 1x Helm, 3x Ear protectors;ChB, FiH, JuL, LiA, MiS;;;
130:50;EGSE/ MRL;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;;1;;;;00:10;
130:40;EGSE/ MRL;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;1;;;;00:10;
110:00;MRL;Confirm that all hatches are closed;;1;;;;01:00;
109:00;MRL;Check He bottle 1 connector is attached;;1;;;;;
109:00;MRL;Check He bottle 2 connector is attached;;1;;;;;
@ -139,15 +139,15 @@ vers.;v4.10;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
106:00;MRL;Check Harris PPR (50 to 8 bar);;2;;;;;
106:00;MRL;Check pneumatic PPG (8 bar);;2;;;;;
106:00;MRL;Step back;;2;;;;01:00;
105:00;EGSE/MRL;Open & Close HPV1 SHORTLY & Check HPPT1;;2;;;;;
105:00;EGSE/ MRL;Open & Close HPV1 SHORTLY & Check HPPT1;;2;;;;;
105:00;EGSE;Check HPPT1 300 Bar;;2;;;;;
105:00;EGSE;Confirm HPLPT 0 Bar;;2;;;;;
105:00;EGSE/MRL;Open & Close HPV2 SHORTLY & Check HPPT2 0 bar;;2;;;;;
105:00;EGSE/MRL;Open & Close HPDV SHORTLY & Check HPLPT 0 bar;;2;;;;;
105:00;EGSE/MRL;Open & Close OxV1 SHORTLY;;2;;;;;
105:00;EGSE/MRL;Open & Close OxV2 SHORTLY;;2;;;;;
105:00;EGSE/MRL;Open & Close OxDV SHORTLY;;2;;;;;
105:00;EGSE/MRL;Open & Close MPV3 SHORTLY;;2;;;;;
105:00;EGSE/ MRL;Open & Close HPV2 SHORTLY & Check HPPT2 0 bar;;2;;;;;
105:00;EGSE/ MRL;Open & Close HPDV SHORTLY & Check HPLPT 0 bar;;2;;;;;
105:00;EGSE/ MRL;Open & Close OxV1 SHORTLY;;2;;;;;
105:00;EGSE/ MRL;Open & Close OxV2 SHORTLY;;2;;;;;
105:00;EGSE/ MRL;Open & Close OxDV SHORTLY;;2;;;;;
105:00;EGSE/ MRL;Open & Close MPV3 SHORTLY;;2;;;;;
00:00;MRL;Open HPNV1;;2;;;;;;
10:10;MRL;????!!!!DO NOT EXECUTE BEFORE DISCUSSION!!!!!Open HPNV2 1/8 Rev;;2;;;;;
00:00;MRL;Step Back;;2;;;;;;
@ -160,8 +160,8 @@ vers.;v4.10;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
00:00;EGSE;Open HPV2 & confirm HPPT2 0 Bar;;2;;;;;
00:00;EGSE;Close HPV2;;2;;;;;
00:00;EGSE;Close HPDV;;2;;;;;
87:10;EGSE;Open & Close STEPWISE MPV1/MPV2 to 50 Bar @ OxInPT1 & OxInPT2;;2;;;;;
87:10;EGSE;Confirm MPV1/MPV2 closed;;2;;;;;
87:10;EGSE;Open & Close STEPWISE MPV1/2 to 50 Bar @ OxInPT1 & OxInPT2;;2;;;;;
87:10;EGSE;Confirm MPV1/2 closed;;2;;;;;
87:10;EGSE;Open OxDV;;2;;;;;
87:10;EGSE;Open & Close STEPWISE MPV3 to 0 Bar @OxOutPT;;2;;;;;
87:10;EGSE;Check OxInPT1 and OxInPT2 for leakage (If leakage occurs proceed to "GSE passivation Procedure";;2;;;;;
@ -177,12 +177,12 @@ vers.;v4.10;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
103:10;EGSE;Move arm to rocket;;2;;;;01:00;
102:10;MRL;Close He Bottle 1 and check HPSM for leakage (If leakage occurs continue with Passivation Procedure);;2;;;;01:00;
101:10;MRL;Open MBV;;2;;;;;
101:10;EGSE/MRL;Check and compare pressure HPPT1 with HPPG1 0 Bar;;2;;;;;
101:10;EGSE/ MRL;Check and compare pressure HPPT1 with HPPG1 0 Bar;;2;;;;;
101:10;MRL;Close MBV;;2;;;;00:30;
100:40;MRL;Open RMDV & relief pressure;;2;;;;;
100:40;MRL;Close RMDV;;2;;;;;
100:40;MRL;Safety is ensured;;2;;;;;
100:40;MCC;EGSE@MRL to MRL;;1;;;;;
100:40;MCC;EGSE @MRL to MRL;;1;;;;;
100:40;EGSE;Switch OFF N20 coupling;;1;;;;;
100:40;EGSE;Switch OFF He coupling;;1;;;;;
100:40;MRL;Confirm working personel is grounded;;1;;;;01:00;
@ -194,12 +194,12 @@ vers.;v4.10;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
99:50;MRL;Couple N2O coupling;;1;;;;00:30;
99:50;MRL;Confirm He coupling is connected properly;;1;;;;;
99:50;MRL;Confirm N2O coupling is connected properly;;1;;;;;
130:50;EGSE/MRL;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;;1;;;;00:10;
130:40;EGSE/MRL;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;1;;;;00:10;
130:50;EGSE/ MRL;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;;1;;;;00:10;
130:40;EGSE/ MRL;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;1;;;;00:10;
99:20;MRL;HOLD;HOLD;1;;;;;
99:20;MCC;CONTINUE AFTER HOLD;;;;;;;
130:50;EGSE/MRL;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;;1;;;;00:10;
130:40;EGSE/MRL;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;1;;;;00:10;
130:50;EGSE/ MRL;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;;1;;;;00:10;
130:40;EGSE/ MRL;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;1;;;;00:10;
99:20;MRL;BEGIN SEQUENCE: Prime Rocket;Prime Rocket;1;;;;;
99:20;EGSE;Turn ON EPS_BAT;;1;;;;01:00;
99:20;MRL;Confirm working personel is grounded;;1;;;;01:00;
@ -208,12 +208,12 @@ vers.;v4.10;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
99:20;MRL;Connect Ignition Umbilical;;1;;;;00:30;
98:30;MRL;Insert all EPS Bridges;;1;;;;03:00;
95:30;MRL;Confirm Bridge Hatch is Secured;;1;;;;00:20;
95:10;EGSE@MRL;return to MCC;;1;;;;;
95:10;EGSE @MRL;return to MCC;;1;;;;;
95:10;OPS;Elevate MRL to 90 degrees;;1;;;;05:00;
89:40;EGSE;Calibrate loadcell (Set to 0);;1;;;;01:00;
88:40;MCC;BEGIN SEQUENCE: Fueling Preparations (PHASE YELLOW);Fueling Preparations;2;;;;;
130:50;EGSE/MRL;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;;1;;;;00:10;
130:40;EGSE/MRL;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;1;;;;00:10;
130:50;EGSE/ MRL;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;;1;;;;00:10;
130:40;EGSE/ MRL;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;1;;;;00:10;
127:40;OBDH;Check RDV;;1;;;;00:10;
127:30;OBDH;Check RNCEV;;1;;;;00:10;
127:20;OBDH;Check RMOxOV;;1;;;;00:10;
@ -233,37 +233,37 @@ vers.;v4.10;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
00:00;EGSE;Confirm HPV2 is closed;;2;;;;;
10:10;MRL;Open HPNV2 1/8 Rev;;2;;;;;
00:00;EGSE;Close HPDV;;2;;;;;
87:10;EGSE;Open & Close STEPWISE MPV1/MPV2 to 50 Bar @ OxInPT1 & OxInPT2;;2;;;;;
87:10;EGSE/MRL;Check & compare OxInPT1 with OxInPG1 based on Bottle temperature (max 50 bar);;2;;;;;
87:10;EGSE/MRL;Check & compare pressure OxInPT2 with OxInPG2 based on Bottle temperature (max 50 bar);;2;;;;;
87:10;EGSE/MRL;Check Temperature of N2O Bottle 1 @OxT1 & OxWT1 (max 22C);;2;;;;;
87:10;EGSE/MRL;Check Temperature of N2O Bottle 2 @OxT2 & OxWT2 (max 22C);;2;;;;01:30;
87:10;EGSE;Open & Close STEPWISE MPV1/2 to 50 Bar @ OxInPT1 & OxInPT2;;2;;;;;
87:10;EGSE/ MRL;Check & compare OxInPT1 with OxInPG1 based on Bottle temperature (max 50 bar);;2;;;;;
87:10;EGSE/ MRL;Check & compare pressure OxInPT2 with OxInPG2 based on Bottle temperature (max 50 bar);;2;;;;;
87:10;EGSE/ MRL;Check Temperature of N2O Bottle 1 @OxT1 & OxWT1 (max 22C);;2;;;;;
87:10;EGSE/ MRL;Check Temperature of N2O Bottle 2 @OxT2 & OxWT2 (max 22C);;2;;;;01:30;
85:40;MRL;Open He Bottle 2;;2;;;;;
85:40;EGSE/MRL;Check & compare pressure HPPT2 with HPPG2 (max 315 bar);;2;;;;01:00;
84:40;ALL/MRL;CAUTION!;;2;;;;;
85:40;EGSE/ MRL;Check & compare pressure HPPT2 with HPPG2 (max 315 bar);;2;;;;01:00;
84:40;ALL/ MRL;CAUTION!;;2;;;;;
84:40;MRL;Open N2O Bottle 1;;2;;;;;
84:40;MRL/EGSE;Check & compare pressure OxInPT 1 with OxInPG 1 (max 50 bar);;2;;;;02:00;
84:40;MRL/ EGSE;Check & compare pressure OxInPT 1 with OxInPG 1 (max 50 bar);;2;;;;02:00;
82:40;MRL;Open N2O Bottle 2;;2;;;;;
82:40;MRL/EGSE;Check & compare pressure OxInPT 2 with OxInPG 2 (max 50 bar);;2;;;;02:00;
82:40;MRL/ EGSE;Check & compare pressure OxInPT 2 with OxInPG 2 (max 50 bar);;2;;;;02:00;
80:40;MRL;Insert Ignition Bridges B1 and B2 into EGSE;;2;;;;02:00;
78:40;MRL;Confirm Soundsignal from Ignition Umbilical;;2;;;;;
78:40;MRL;Close ComTerm & Go to Block House;;2;;;;;
78:40;MCC;Turn OFF MRL confirm lock;;2;;;;;
78:40;ALL;Inform OPS to clear Launch Pad (Tel.: [!!!]);;2;;;;2:00;
147:20;WIND;Start wind weighting analysis;;1;;;;;
130:50;EGSE/MRL;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;;1;;;;00:10;
130:40;EGSE/MRL;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;1;;;;00:10;
130:50;EGSE/ MRL;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;;1;;;;00:10;
130:40;EGSE/ MRL;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;1;;;;00:10;
68:40;MCC;HOLD;HOLD;2;;;;;
68:40;KLP;Start Camera Karsten Lappöhn;;2;;;;;
68:40;MCC;CONTINUE AFTER HOLD;2;;;;;;
130:50;EGSE/MRL;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;;1;;;;00:10;
130:40;EGSE/MRL;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;1;;;;00:10;
130:50;EGSE/ MRL;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;;1;;;;00:10;
130:40;EGSE/ MRL;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;1;;;;00:10;
130:40;EGSE;Confirm storage capacity of CRio is greater than [!!!];;1;;;;00:10;
68:40;MCC;BEGIN SEQUENCE Ox Fueling (PHASE RED);Ox Fueling (PHASE RED);3;;;;;
68:50;WIND;Report on weather situation;;1;;;;;
68:40;MCC;Announce end of Radio Silence;;3;;;;;
68:40;EGSE;Turn OFF EPS_BAT;;3;;;;;
126:50;OBDH/TMTC;Check RF451-Link;;1;;;;00:20;
126:50;OBDH/ TMTC;Check RF451-Link;;1;;;;00:20;
126:30;TMTC;Confirm GPS-lock;;1;;;;00:20;
126:10;TMTC;Confirm Telemega-Link;;1;;;;00:20;
125:50;OBDH;Test Connection to STX3;;1;;;;00:20;
@ -276,9 +276,9 @@ vers.;v4.10;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
67:40;EGSE;Open & Close HPV1 STEPWISE to more than 50 Bar @ RHPPT and confirm ROxTPT 50 Bar;;3;;;;;
67:40;EGSE;Confirm HPV1 is closed;;3;;;;;
67:40;OBDH;Open RDV SHORTLY, to check tightness @ RHPPT & ROxTPT (If leakages occur continue with Abort Procedure);;3;;;;;
67:40;EGSE;Open MPV1/MPV2;;3;;;;;
67:40;EGSE;Open MPV1/2;;3;;;;;
67:40;EGSE;Open & Close MPV3 STEPWISE to 50 Bar @ OxOutPT;;3;;;;;
67:40;EGSE;Close MPV1/MPV2;;3;;;;;
67:40;EGSE;Close MPV1/2;;3;;;;;
67:40;EGSE;Check & compare OxOutPT with OxInPT1;;3;;;;;
67:40;EGSE;Check if RHPPT & ROxTPT more than OxInPT1, If less Open & Close HPV1;;3;;;;;
67:40;EGSE;Zero OxTank Mass;;3;;;;;
@ -306,7 +306,7 @@ vers.;v4.10;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
9:50;EGSE;Decouple N2O coupling;;3;;;;00:20;
9:30;MCC;Confirm End of Oxidator Fueling to OPS;;3;;;;00:15;
9:20;WIND;Start wind weighting analysis;;1;;;;;
9:15;OBDH/TMTC;Check RF451-Link;;3;;;;00:20;
9:15;OBDH/ TMTC;Check RF451-Link;;3;;;;00:20;
8:55;TMTC;Check GPS-lock;;3;;;;00:20;
8:35;TMTC;Check Telemega-Link;;3;;;;00:20;
33:40;EGSE;Verify He Bottle 2 Temperature @HPT2 & @HPWT2 (turn ON/OFF He_Heater if necessary) ;;1;;;;00:10;
@ -324,7 +324,7 @@ vers.;v4.10;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
8:15;EGSE;Turn OFF EPS_Ext (Switch to internal Power);;3;;;;00:20;
7:55;OBDH;Confirm EPS Voltages are within limits;;3;;;;00:10;
7:45;OBDH;Confirm RF451 Transmitting;;3;;;;00:05;
7:40;OBDH/TMTC;Confirm RF451-Link;;3;;;;00:20;
7:40;OBDH/ TMTC;Confirm RF451-Link;;3;;;;00:20;
7:20;TMTC;Confirm GPS-lock;;3;;;;00:20;
7:00;TMTC;Confirm Telemega-Link;;3;;;;00:20;
6:40;OBDH;Switch to PREARMED;;3;;;;00:10;
@ -337,7 +337,7 @@ vers.;v4.10;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
6:05;EGSE;Open & Close HPV2 STEPWISE until RHPPT 300 Bar ;;3;;;;;
6:05;EGSE;Open & close HPDV STEPWISE until HPLPT 0 Bar ;;3;;;;;
6:05;EGSE;Confirm HPDV closed;;3;;;;;
6:05;OBDH/EGSE;Check for leakage & HPLPT 0 Bar & RHPPT 300 Bar ;;3;;;;02:00;
6:05;OBDH/ EGSE;Check for leakage & HPLPT 0 Bar & RHPPT 300 Bar ;;3;;;;02:00;
6:05;EGSE;Turn OFF He_Heater;;3;;;;;
4:05;OBDH;Acknowledge end of Fueling;;3;;;;00:10;
3:55;MCC;Confirm End of Fueling to OPS;;3;;;;00:20;
@ -401,7 +401,7 @@ vers.;v4.10;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
0:00;EGSE;Close HPDV;;2;;;;;
0:00;EGSE;Pressure Check;;2;;;;;
0:00;MRL;Open MBV;;2;;;;;
0:00;EGSE/MRL;Check and compare pressure HPPT1 with HPPG1;;2;;;;;
0:00;EGSE/ MRL;Check and compare pressure HPPT1 with HPPG1;;2;;;;;
0:00;MRL;Close MBV;;2;;;;;
0:00;MRL;Take out B1 & B2 Bridges;;2;;;;;
0:00;MRL;Safety is ensured;;2;;;;;

Can't render this file because it has a wrong number of fields in line 151.