@ -17,18 +17,18 @@ vers.;v3.0;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
144:35;EGSE;Confirm PID-VI is running;;1;;;;; 144:35;EGSE;Confirm PID-VI is running;;1;;;;;
144:35;EGSE;Rename PID-Logfile;;1;;;;02:00; 144:35;EGSE;Rename PID-Logfile;;1;;;;02:00;
142:35;MRL;Confirm working Personel is grounded;;1;;;;; 142:35;MRL;Confirm working Personel is grounded;;1;;;;;
Confirm all 8 Groundingbridges are inserted 0;EGSL@MRL;Confirm all 8 Groundingbridges are inserted;;1;;;;;
142:35;MRL;Connect Data Umbilical;Connect Data Umbilical;1;;;;00:30; 142:35;MRL;Connect Data Umbilical;Connect Data Umbilical;1;;;;00:30;
EGSE;Turn on EPS_BAT 0;EGSE;Turn on EPS_BAT;;1;;;;;
EGSE;Turn on EPS_EXT 0;EGSE;Turn on EPS_EXT;;1;;;;;
EGSE@MRL;Remove 7 Grounding Bridges and leave EPS_BAT inserted 0;EGSE@MRL;Remove 7 Grounding Bridges and leave EPS_BAT inserted;;1;;;;;
EGSE@MRL;Insert EPS_EXT Fuse in Power Supply Control Panel 0;EGSE@MRL;Insert EPS_EXT Fuse in Power Supply Control Panel;;1;;;;;
EGSE@MRL;Confirm green LED at EPS_EXT Fuse is on 0;EGSE@MRL;Confirm green LED at EPS_EXT Fuse is on;;1;;;;;
EGSE@MRL;Insert Main_Bus Fuse in Power Supply Control Panel 0;EGSE@MRL;Insert Main_Bus Fuse in Power Supply Control Panel;;1;;;;;
EGSE@MRL;Confirm LED at Main_Bus Fuse is OFF. Else Pull fuse and insert all Grounding Bridges 0;EGSE@MRL;Confirm LED at Main_Bus Fuse is OFF. Else Pull fuse and insert all Grounding Bridges;;1;;;;;
EGSE@MRL;Set remaining Fuses (except Payload Fuse) and check for green LED 0;EGSE@MRL;Set remaining Fuses (except Payload Fuse) and check for green LED;;1;;;;;
EGSE;Turn OFF EPS_BAT 0;EGSE;Turn OFF EPS_BAT;;1;;;;;
EGSE@MRL;Confirm Main bus LED is on. 0;EGSE@MRL;Confirm Main bus LED is on.;;1;;;;;
142:05;EGSE;Start EPS via EPS_ext;;1;;;;; 142:05;EGSE;Start EPS via EPS_ext;;1;;;;;
140:05;OBDH;Clear SD-Card-using FileZilla FTP;;;;;;01:00; 140:05;OBDH;Clear SD-Card-using FileZilla FTP;;;;;;01:00;
139:05;OBDH;Connect to sbRIO;;1;;;;; 139:05;OBDH;Connect to sbRIO;;1;;;;;
@ -36,8 +36,8 @@ EGSE@MRL;Confirm Main bus LED is on.
139:05;MRL;Confirm 3 beeps at OBC1;;1;;;;; 139:05;MRL;Confirm 3 beeps at OBC1;;1;;;;;
139:05;OBDH;Open RT_Sub_HMI;;1;;;;; 139:05;OBDH;Open RT_Sub_HMI;;1;;;;;
139:05;OBDH;Confirm Main Chute button is disabled;;1;;;;; 139:05;OBDH;Confirm Main Chute button is disabled;;1;;;;;
EGSE@MRL;Insert Payload Fuse 0;EGSE@MRL;Insert Payload Fuse
EGSE@MRL;Confirm green LED at Payload Fuse is on 0;EGSE@MRL;Confirm green LED at Payload Fuse is on
139:05;MRL;Confirm working Personel is grounded;;1;;;;01:00; 139:05;MRL;Confirm working Personel is grounded;;1;;;;01:00;
138:05;MRL;Remove Pneumatic Line from Fueling arm;;1;;;;; 138:05;MRL;Remove Pneumatic Line from Fueling arm;;1;;;;;
138:05;MRL;Move Fueling arm to rocket;;1;;;;; 138:05;MRL;Move Fueling arm to rocket;;1;;;;;
@ -297,7 +297,7 @@ EGSE@MRL;Confirm green LED at Payload Fuse is on
00:00;EGSE;Close HPV2;;2;;;;; 00:00;EGSE;Close HPV2;;2;;;;;
00:00;EGSE;Close HPDV;;2;;;;; 00:00;EGSE;Close HPDV;;2;;;;;
00:00;MRL;Go to Testrig, confirm HPPG2 0 Bar, else return to BlockHouse, then open ComTerm;;2;;;;; 00:00;MRL;Go to Testrig, confirm HPPG2 0 Bar, else return to BlockHouse, then open ComTerm;;2;;;;;
12960:00;MRL;Close N2 Bottle;;2;;;;; 00:00;MRL;Close N2 Bottle;;2;;;;;
00:00;MRL;Write down remaining Pressure of N2 Bottle;;2;;;;; 00:00;MRL;Write down remaining Pressure of N2 Bottle;;2;;;;;
00:00;MRL;Step back;;2;;;;; 00:00;MRL;Step back;;2;;;;;
00:00;MRL;Check EPV manometer less than 6 bar;;2;;;;; 00:00;MRL;Check EPV manometer less than 6 bar;;2;;;;;

Can't render this file because it has a wrong number of fields in line 20.