changes from testrun 03.juni 2020

This commit is contained in:
Finn 2020-06-03 16:00:21 +02:00
parent 71a3e060d6
commit d971473e07
1 changed files with 46 additions and 46 deletions

View File

@ -1,4 +1,4 @@
vers.;v4.13;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
vers.;v4.14;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
147:20;WIND;Start wind weighting analysis;;1;;;;;
147:20;MCC;BEGIN SEQUENCE: Power on EGSE;Power on EGSE;1;;;;;
147:20;EGSE;Check CLD connection;;1;;;;;
@ -13,7 +13,7 @@ vers.;v4.13;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
146:20;EGSE @MRL;Switch ON Sup_24V_40A;;1;;;;;
146:20;EGSE @MRL;Switch ON Sup_5V_10A;;1;;;;03:00;
143:20;EGSE;Connect to cRio;;1;;;;;
130:40;EGSE;Confirm storage capacity of cRio is greater than [!!!];;1;;;;00:10;
130:40;EGSE;Confirm storage capacity of cRio is greater than 300MB;;;;00:10;
143:20;EGSE;Start RT_VI;;1;;;;;
143:20;EGSE;Open PID-VI and confirm it is running;;1;;;;;
143:20;EGSE;Rename PID-Logfile;;1;;;;02:00;
@ -49,7 +49,7 @@ vers.;v4.13;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
138:50;MRL;Couple Helium coupling;;1;;;;;
138:50;MRL;Couple N2O coupling;;1;;;;;
138:50;MRL;Reattach Pneumatic Line to Fueling arm;;1;;;;03:00;
135:50;EGSE;BEGIN SEQUENCE: EGSE Valve and Actuator check;EGSE Valve & Actuator Check;1;;;;;
135:50;EGSE;BEGIN SEQUENCE: EGSE sensor and actuator test;EGSE sensor & actuator test;1;;;;;
135:50;MCC;Confirm that video recording is enabled @ MCC;;1;;;;00:10;
135:50;MRL;Confirm that Ignition Umbilical is disconnected;;1;;;;;
135:40;OBDH;Check EPS hardware Voltages;;1;;;;00:10;
@ -68,22 +68,22 @@ vers.;v4.13;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
130:50;EGSE/ MRL;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;;1;;;;00:10;
130:40;EGSE/ MRL;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;1;;;;00:10;
130:30;EGSE;Deactivate Heizi;;1;;;;00:10;
130:20;EGSE;Check OxV1 (CLD & RT_VI);;1;;;;00:10;
130:10;EGSE;Check OxV2 (CLD & RT_VI);;1;;;;00:10;
130:00;EGSE;Check MPV3 (CLD & RT_VI);;1;;;;00:10;
129:50;EGSE;Check HPV1 (CLD & RT_VI);;1;;;;00:10;
129:40;EGSE;Check HPV2 (CLD & RT_VI);;1;;;;00:10;
129:30;EGSE;Check MPV1/2 (CLD & RT_VI);;1;;;;00:10;
129:20;EGSE;Check RDV (CLD & RT_VI);;1;;;;00:10;
129:10;EGSE;Check RMOxOV (CLD & RT_VI);;1;;;;00:10;
129:00;EGSE;Check RMOxSV (CLD & RT_VI);;1;;;;00:10;
130:20;EGSE/ MRL;Check OxV1 (CLD & RT_VI);;1;;;;00:10;
130:10;EGSE/ MRL;Check OxV2 (CLD & RT_VI);;1;;;;00:10;
130:00;EGSE/ MRL;Check MPV3 (CLD & RT_VI);;1;;;;00:10;
129:50;EGSE/ MRL;Check HPV1 (CLD & RT_VI);;1;;;;00:10;
129:40;EGSE/ MRL;Check HPV2 (CLD & RT_VI);;1;;;;00:10;
129:30;EGSE/ MRL;Check MPV1/2 (CLD & RT_VI);;1;;;;00:10;
129:20;EGSE/ MRL;Check RDV (CLD & RT_VI);;1;;;;00:10;
129:10;EGSE/ MRL;Check RMOxOV (CLD & RT_VI);;1;;;;00:10;
129:00;EGSE/ MRL;Check RMOxSV (CLD & RT_VI);;1;;;;00:10;
128:50;OBDH;Activate Heizi;;1;;;;00:10;
128:40;OBDH;Verify Heizi @ RDVT & RDVET;;1;;;;01:00;
127:40;OBDH;Check RDV;;1;;;;00:10;
127:30;OBDH;Check RNCEV;;1;;;;00:10;
127:20;OBDH;Check RMOxOV;;1;;;;00:10;
127:10;OBDH;Check RMOxSV;;1;;;;00:10;
127:00;OBDH;Confirm RNCEV is disabled;;1;;;;00:10;
127:40;OBDH/ MRL;Check RDV;;1;;;;00:10;
127:30;OBDH/ MRL;Check RNCEV;;1;;;;00:10;
127:20;OBDH/ MRL;Check RMOxOV;;1;;;;00:10;
127:10;OBDH/ MRL;Check RMOxSV;;1;;;;00:10;
127:00;OBDH/ MRL;Disable RNCEV;;1;;;;00:10;
125:00;MRL;Confirm MBV closed;;1;;;;;
125:00;EGSE;Confirm that all valve switches are in OFF position (Except OxDV & HPDV);;1;;;;0:10;
115:00;MRL/ EGSE;Check loadcell by applying force to it;;1;;;;00:20;
@ -118,19 +118,19 @@ vers.;v4.13;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
130:50;EGSE/ MRL;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;;1;;;;00:10;
130:40;EGSE/ MRL;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;1;;;;00:10;
110:00;MRL;Confirm that all hatches are closed;;1;;;;01:00;
109:00;MRL;Check He bottle 1 connector is attached;;1;;;;;
109:00;MRL;Check He bottle 2 connector is attached;;1;;;;;
109:00;MRL;Check N2O bottle 1 connector is attached;;1;;;;;
109:00;MRL;Check N2O bottle 2 connector is attached;;1;;;;;
109:00;MRL;Check hose between HPSM & N2OSM is connected on both ends;;1;;;;;
109:00;MRL;Check hose between HPSM & Flight Segment is connected on both ends;;1;;;;;
109:00;MRL;Check hose between N2OSM & Flight Segment is connected on both ends;;1;;;;;
109:00;MRL;Check pneumatic hose is connected on both ends;;1;;;;02:00;
109:00;MRL;Confirm He bottle 1 connector is attached;;1;;;;;
109:00;MRL;Confirm He bottle 2 connector is attached;;1;;;;;
109:00;MRL;Confirm N2O bottle 1 connector is attached;;1;;;;;
109:00;MRL;Confirm N2O bottle 2 connector is attached;;1;;;;;
109:00;MRL;Confirm hose between HPSM & N2OSM is connected on both ends;;1;;;;;
109:00;MRL;Confirm hose between HPSM & Flight Segment is connected on both ends;;1;;;;;
109:00;MRL;Confirm hose between N2OSM & Flight Segment is connected on both ends;;1;;;;;
109:00;MRL;Confirm pneumatic hose is connected on both ends;;1;;;;02:00;
107:00;MRL;Put on safety equipment;;2;;;;;
107:00;MRL;Confirm MBV is closed;;2;;;;;
107:00;MRL;Confirm HPNV1 is closed;;2;;;;;
107:00;MRL;Confirm HPNV2 is closed;;2;;;;;
107:00;MRL;Take position to open He Bottle 1;;2;;;;;
107:00;MRL;Take positions to open He Bottle 1;;2;;;;;
107:00;EGSE;Confirm HPV1 is closed;;2;;;;;
107:00;EGSE;Confirm MPV1/2 is closed;;2;;;;;
107:00;MRL;Open He Bottle 1;;2;;;;01:00;
@ -142,14 +142,13 @@ vers.;v4.13;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
105:00;EGSE/ MRL;Open & Close HPV1 SHORTLY & Check HPPT1;;2;;;;;
105:00;EGSE;Check HPPT1 300 Bar;;2;;;;;
105:00;EGSE;Confirm HPLPT 0 Bar;;2;;;;;
105:00;EGSE/ MRL;Open & Close HPV2 SHORTLY & Check HPPT2 0 bar;;2;;;;;
105:00;EGSE/ MRL;Open & Close HPDV SHORTLY & Check HPLPT 0 bar;;2;;;;;
105:00;EGSE/ MRL;Open & Close HPV2 SHORTLY & Confirm HPPT2 0 bar;;2;;;;;
105:00;EGSE/ MRL;Open & Close HPDV SHORTLY & Confirm HPLPT 0 bar;;2;;;;;
105:00;EGSE/ MRL;Open & Close OxV1 SHORTLY;;2;;;;;
105:00;EGSE/ MRL;Open & Close OxV2 SHORTLY;;2;;;;;
105:00;EGSE/ MRL;Open & Close OxDV SHORTLY;;2;;;;;
105:00;EGSE/ MRL;Open & Close MPV3 SHORTLY;;2;;;;;
00:00;MRL;Open HPNV1;;2;;;;;;
10:10;MRL;????!!!!DO NOT EXECUTE BEFORE DISCUSSION!!!!!Open HPNV2 1/8 Rev;;2;;;;;
00:00;MRL;Step Back;;2;;;;;;
00:00;EGSE;Open & Close HPV1 STEPWISE untile HPLPT equal to HPPT1 and check for leakage @HPLPT (If leakage occurs continue with "GSE Passivation Procedure");;2;;;;;
00:00;EGSE;Confirm RHPPT & RoxTPT less than 1 Bar (on Pressure continue with "Rocket Passivation Procedure");;2;;;;;
@ -170,7 +169,7 @@ vers.;v4.13;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
87:10;EGSE;Open & Close STEPWISE OxV2 to 0 Bar @OxInPT2;;2;;;;;
87:10;EGSE;Confirm OxOutPT 0 Bar;;2;;;;;
87:10;EGSE;Close OxDV;;2;;;;;
105:00;EGSE;Check HPLPT & OxOutPT 0 Bar;;2;;;;01:30;
105:00;EGSE;Confirm HPLPT & OxOutPT 0 Bar;;2;;;;01:30;
103:30;EGSE;Decouple N2O coupling;;2;;;;;
103:30;EGSE;Decouple Helium coupling;;2;;;;00:20;
103:10;EGSE;Move arm away from rocket;;2;;;;;
@ -189,7 +188,7 @@ vers.;v4.13;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
100:40;MRL;Confirm PPG 0 Bar;;1;;;;00:20;
100:40;MRL;Release Pneumatic lines of couplings;;1;;;;00:20;
100:20;EGSE;Confirm Fueling arm is switched OFF;;1;;;;;
100:20;EGSE;Check OxOutPT and HPLPT 0 bar;;1;;;;;
100:20;EGSE;Confirm OxOutPT and HPLPT 0 bar;;1;;;;;
100:20;MRL;Couple He coupling;;1;;;;00:30;
99:50;MRL;Couple N2O coupling;;1;;;;00:30;
99:50;MRL;Confirm He coupling is connected properly;;1;;;;;
@ -210,15 +209,15 @@ vers.;v4.13;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
95:30;MRL;Confirm Bridge Hatch is Secured;;1;;;;00:20;
95:10;EGSE @MRL;return to MCC;;1;;;;;
95:10;OPS;Elevate MRL to 90 degrees;;1;;;;05:00;
89:40;EGSE;Calibrate loadcell (Set to 0);;1;;;;01:00;
89:40;EGSE;Zero OxTank Mass;;1;;;;01:00;
88:40;MCC;BEGIN SEQUENCE: Fueling Preparations (PHASE YELLOW);Fueling Preparations;2;;;;;
130:50;EGSE/ MRL;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;;1;;;;00:10;
130:40;EGSE/ MRL;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;1;;;;00:10;
127:40;OBDH;Check RDV;;1;;;;00:10;
127:30;OBDH;Check RNCEV;;1;;;;00:10;
127:20;OBDH;Check RMOxOV;;1;;;;00:10;
127:10;OBDH;Check RMOxSV;;1;;;;00:10;
127:00;OBDH;Confirm RNCEV is disabled;;1;;;;00:10;
127:40;OBDH;!!!Check RDV;;1;;;;00:10;
127:30;OBDH;!!!Check RNCEV;;1;;;;00:10;
127:20;OBDH;!!!Check RMOxOV;;1;;;;00:10;
127:10;OBDH;!!!Check RMOxSV;;1;;;;00:10;
127:00;OBDH;!!!Disable RNCEV;;1;;;;00:10;
88:40;MRL;Put on safety equipment;;2;;;;00:30;
10:10;MRL;Confirm HPNV1 is Open;;2;;;;;
10:10;MRL;Confirm HPNV2 is Closed;;2;;;;;
@ -258,16 +257,17 @@ vers.;v4.13;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
68:40;MCC;CONTINUE AFTER HOLD;2;;;;;;
130:50;EGSE/ MRL;Check Bottle Temperatures @ OxT1, OxT2, HPT2. If above 30C aknowledge high temperature. If above 35C enter HOLD;;1;;;;00:10;
130:40;EGSE/ MRL;Check Water Temperatures @ OxWT1, OxWT2, HPWT2;;1;;;;00:10;
130:40;EGSE;Confirm storage capacity of CRio is greater than [!!!];;1;;;;00:10;
130:40;EGSE;Confirm storage capacity of CRio is greater than 300MB;;1;;;;00:10;
127:00;OBDH;Confirm RNCEV is disabled;;1;;;;00:10;
68:40;MCC;BEGIN SEQUENCE Ox Fueling (PHASE RED);Ox Fueling (PHASE RED);3;;;;;
68:50;WIND;Report on weather situation;;1;;;;;
68:40;MCC;Announce end of Radio Silence;;3;;;;;
68:40;EGSE;Turn OFF EPS_BAT;;3;;;;;
126:50;OBDH/ TMTC;Check RF451-Link;;1;;;;00:20;
126:50;OBDH/ TMTC;Confirm RF451-Link;;1;;;;00:20;
126:30;TMTC;Confirm GPS-lock;;1;;;;00:20;
126:10;TMTC;Confirm Telemega-Link;;1;;;;00:20;
125:50;OBDH;Test Connection to STX3;;1;;;;00:20;
125:30;OBDH;Confirm that STX3 Package received by email;;1;;;;00:30;
125:30;OBDH;Confirm that STX3 Packages are received by email;;1;;;;00:30;
125:30;AVC;Turn on main TMTC screen;;1;;;;00:30;
125:30;MCC;Request Permission to begin fueling from OPS;;1;;;;03:00;
68:40;OBDH;Acknowledge start of Fueling;;3;;;;01:00;
@ -302,7 +302,7 @@ vers.;v4.13;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
33:40;EGSE;Verify He Bottle 2 Temperature @HPT2 & @HPWT2 (turn ON He_Heater if necessary) ;;1;;;;00:10;
10:20;MCC;Provide OxTankMass and temperature readings to Wind weighting station;;3;;;;00:30;
9:50;EGSE;Confirm OxV1 & OxV2 closed;;3;;;;;
9:50;EGSE;Check OxOutPT 0 Bar;;3;;;;;
9:50;EGSE;Confirm OxOutPT 0 Bar;;3;;;;;
9:50;EGSE;Decouple N2O coupling;;3;;;;00:20;
9:30;MCC;Confirm End of Oxidator Fueling to OPS;;3;;;;00:15;
9:20;WIND;Start wind weighting analysis;;1;;;;;
@ -343,7 +343,7 @@ vers.;v4.13;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
3:55;MCC;Confirm End of Fueling to OPS;;3;;;;00:20;
3:35;MCC;BEGIN SEQUENCE: Disconnecting Fueling Arm;Disconnecting Fueling Arm;3;;;;00:10;
3:25;EGSE;Confirm HPV1 & HPV2 closed;;3;;;;00:10;
3:15;EGSE;Check HPLPT 0 Bar ;;3;;;;00:10;
3:15;EGSE;Confirm HPLPT 0 Bar ;;3;;;;00:10;
3:05;EGSE;Decouple Helium coupling;;3;;;;00:20;
2:45;EGSE;Confirm Helium coupling is disconnected;;3;;;;00:10;
2:35;EGSE;Move fueling arm away from rocket;;3;;;;00:40;
@ -373,10 +373,10 @@ vers.;v4.13;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
0:00;MRL;RETURN to Block House;;2;;;;;
0:00;EGSE;Open OxDV;;2;;;;;
0:00;EGSE;Open OxV1;;2;;;;;
0:00;EGSE;Check OxInPT1 & OxOutPT 0 Bar;;2;;;;;
0:00;EGSE;Confirm OxInPT1 & OxOutPT 0 Bar;;2;;;;;
0:00;EGSE;Close OxV1;;2;;;;;
0:00;EGSE;Open OxV2;;2;;;;;
0:00;EGSE;Check OxInPT2 & OxOutPT 0 Bar;;2;;;;;
0:00;EGSE;Confirm OxInPT2 & OxOutPT 0 Bar;;2;;;;;
0:00;EGSE;Close OxV2;;2;;;;;
0:00;EGSE;Close OxDV ;;2;;;;;
0:00;MRL;Go to MRL, confirm OxInPG1 & OxInPG2 0 Bar, else RETURN to Block House, THEN...
@ -385,7 +385,7 @@ vers.;v4.13;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
0:00;MRL;Return to Block House;;2;;;;;
0:00;EGSE;Open HPDV;;2;;;;;
0:00;EGSE;Open HPV2;;2;;;;;
0:00;EGSE;Check pressure HPLPT & HPPT2 0 Bar;;2;;;;;
0:00;EGSE;Confirm pressure HPLPT & HPPT2 0 Bar;;2;;;;;
0:00;EGSE;Close HPV2;;2;;;;;
0:00;EGSE;Close HPDV;;2;;;;;
0:00;MRL;Go to Testrig, confirm HPPG2 0 Bar, else return to Block House, THEN...;;2;;;;;
@ -396,7 +396,7 @@ vers.;v4.13;Launch Procedure;;0;MRL;MCC;RdHill;Time per step;
0:00;MRL;Step back;;2;;;;;
0:00;EGSE;Open HPDV;;2;;;;;
0:00;EGSE;Open HPV1;;2;;;;;
0:00;EGSE;Check pressure HPLPT & HPPT1 0 Bar;;2;;;;;
0:00;EGSE;Confirm pressure HPLPT & HPPT1 0 Bar;;2;;;;;
0:00;EGSE;Close HPV1;;2;;;;;
0:00;EGSE;Close HPDV;;2;;;;;
0:00;EGSE;Pressure Check;;2;;;;;

Can't render this file because it has a wrong number of fields in line 16.